[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-232223-105":59,"doc-detail-232223-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","heatcraft-pro-3-top-mount-installation-manual-part-no-25001801-september-2010","Heatcraft Pro 3 Top Mount Installation Manual - Part No. 25001801 - September 2010","","Owner installation and operations guidance for the Heatcraft PRO3 top mount packaged refrigeration system for indoor applications. Covers performance and electrical data, cooler and freezer defrost system specifications, dimensional and placement requirements, rigging and mounting instructions, inspection and safety information, standard installation procedures, controller program settings, system troubleshooting, replacement parts, electrical wiring diagrams, and warranty terms.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/heatcraft-pro-3-top-mount-installation-manual-part-no-25001801-september-2010/232223/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/heatcraft-pro-3-top-mount-installation-manual-part-no-25001801-september-2010/232223.png","ImageObject",300,407,{"name":92,"@type":93},"Jiven","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-08","2026-09-10",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",16,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What system information does the manual provide before installation?","Question",{"text":113,"@type":114},"It includes performance/electrical data and specifications, dimensional diagrams, and space and location requirements with recommended unit placement.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What steps are covered for installing the PRO3 top mount packaged refrigeration system?",{"text":118,"@type":114},"The manual provides rigging, mounting, inspection, general safety information, and a standard installation procedure.",{"name":120,"@type":111,"acceptedAnswer":121},"How does the manual support commissioning and maintenance?",{"text":122,"@type":114},"It explains controller program settings, provides a system troubleshooting chart, lists replacement parts, and includes electrical wiring diagrams.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},232223,1789069906,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":130,"read_time":145},1099513958607,"https://ap-avatar.wpscdn.com/avatar/100002390cf8733938c?x-image-process=image/resize,m_fixed,w_180,h_180&k=1778829742770036399","| | Installation and Operations Manual |\n| --- | --- |\n| H-IM-81E September 2010 Part No. 25001801 |  |\n| PRO3 Top Mount Packaged Refrigeration System\u003Cbr>For Indoor Applications |  |\n| \u003Cbr>| Table of Contents\u003Cbr> 1. Owner’s Installation Instructions \u003Cbr>Performance/Electrical Data\u003Cbr>Specifications.................................................................................... 2\u003Cbr>Dimensional Diagrams ..................................................................3\u003Cbr>Space and Location Requirements\u003Cbr>Recommended Unit Placement   4\u003Cbr>Rigging\u003Cbr>Mounting............................................................................................ 5\u003Cbr>Inspection\u003Cbr>General Safety Information\u003Cbr>Standard Installation Procedure   6\u003Cbr>\u003Cbr> 2. Controllers\u003Cbr>Controllers and Program Settings ...................................... 7-17\u003Cbr>\u003Cbr>3. Service Information\u003Cbr>System Troubleshooting Chart................................................ 18\u003Cbr>Replacement Parts ....................................................................... 19\u003Cbr>\u003Cbr> 4. Wiring Information\u003Cbr>Electrical Wiring Diagrams .................................................. 20-25\u003Cbr>5. Warranty Information ........................................................ 26\u003Cbr>© 2010 Heatcraft Refrigeration Products, LLC |\n\n1. Owner’s Operating Instructions  \nInstallation and Operations Manual  \nPERFORMANCE / ELECTRICAL DATA  \n\n| TABLE 1 Cooler Air Defrost Systems |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Model | BTUH @95°F |  | Voltage | MCA | MOPD | Unit\u003Cbr>Amps | Evaporator\u003Cbr>CFM | Plug\u003Cbr>Supplied | Matching\u003Cbr>NEMA\u003Cbr>Receptacle | Fig. | Approx. Net\u003Cbr>Weight |  | Refrig.\u003Cbr>Charge\u003Cbr>R-404A | Total\u003Cbr>Heat of\u003Cbr>Rejection |\n|  | 35° F Box\u003Cbr>Temp | 38° F Box\u003Cbr>Temp |  |  |  |  |  |  |  |  | lbs. | kg | oz. | BTUH |\n| PTN026H6A^ | 2,610 | 2,740 | 115/1/60 | 7.4 | 15 | 5.9 | 340 | Yes | 5-20R | A | 88 | 40 | 12 | 3,000 |\n| PTN031H6A^ | 3,160 | 3,310 | 115/1/60 | 8.3 | 15 | 6.9 | 340 | Yes | 5-20R | A | 90 | 41 | 16 | 3,800 |\n| PTN042H6A^ | 4,360 | 4,570 | 115/1/60 | 11.3 | 15 | 9.3 | 340 | Yes | 5-20R | A | 92 | 42 | 14 | 5,500 |\n| PTN050H6A^ | 5,120 | 5,370 | 115/1/60 | 14.0 | 20 | 11.6 | 350 | Yes | 5-20R | B | 192 | 87 | 27 | 6,700 |\n| PTN050H6B^ | 5,120 | 5,370 | 208-230/1/60 | 7.0 | 15 | 5.9 | 350 | Yes | 6-15R | B | 192 | 87 | 27 | 6,700 |\n| PTN067H6B^ | 6,860 | 7,190 | 208-230/1/60 | 11.5 | 15 | 9.5 | 550 | Yes | 6-15R | B | 207 | 94 | 29 | 8,700 |\n| PTN076H6B^ | 7,500 | 7,840 | 208-230/1/60 | 9.3 | 15 | 7.8 | 500 | Yes | 6-15R | B | 211 | 95 | 32 | 9,700 |\n| PTN104H6B^ | 11,190 | 11,810 | 208-230/1/60 | 14.8 | 20 | 12.4 | 875 | Yes | 6-20R | C | 270 | 122 | 47 | 16,800 |\n| PTN104H6C^ | 11,190 | 11,810 | 208-230/3/60 | 11.0 | 15 | 9.3 | 875 | No | – | C | 265 | 120 | 47 | 16,800 |\n| PTN133H6B^ | 12,790 | 13,500 | 208-230/1/60 | 14.8 | 20 | 12.4 | 825 | Yes | 6-20R | C | 290 | 132 | 52 | 18,000 |\n| PTN133H6C^ | 12,790 | 13,500 | 208-230/3/60 | 11.0 | 15 | 9.3 | 825 | No | – | C | 285 | 129 | 52 | 18,000 |\n\n\n| TABLE 2 Cooler Electric Defrost Systems |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Model | BTUH @95°F | Voltage | MCA | MOPD | Unit\u003Cbr>Amps | Evaporator\u003Cbr>CFM | Plug\u003Cbr>Supplied | Matching\u003Cbr>NEMA\u003Cbr>Receptacle | Fig. | Approx. Net\u003Cbr>Weight |  | Refrig.\u003Cbr>Charge\u003Cbr>R-404A | Total\u003Cbr>Heat of\u003Cbr>Rejection |\n|  | 34° F Box Temp |  |  |  |  |  |  |  |  | lbs. | kg | oz. | BTUH |\n| PTN024M6A^ | 2,610 | 115/1/60 | 7.4 | 15 | 5.9 | 340 | Yes | 5-20R | A | 88 | 40 | 12 | 3,000 |\n| PTN029M6A^ | 3,160 | 115/1/60 | 8.3 | 15 | 6.9 | 340 | Yes | 5-20R | A | 90 | 41 | 16 | 3,800 |\n| PTN040M6A^ | 4,360 | 115/1/60 | 11.3 | 15 | 9.3 | 340 | Yes | 5-20R | A | 92 | 42 | 14 | 5,500 |\n| PTN047M6A^ | 5,120 | 115/1/60 | 14.0 | 20 | 11.6 | 350 | Yes | 5-20R | B | 192 | 87 | 27 | 6,70","cbCaiptsMYZ3vaoU","https://ap.wps.com/l/cbCaiptsMYZ3vaoU","pdf",4260727,28,"English","# Owner’s Installation Instructions\n## Performance/Electrical Data and Specifications\n## Dimensional Diagrams, Space and Location Requirements\n## Rigging and Mounting\n## Inspection and Safety Information\n## Standard Installation Procedure\n# Controllers\n## Controllers and Program Settings\n# Service Information\n## System Troubleshooting Chart\n## Replacement Parts\n# Wiring Information\n## Electrical Wiring Diagrams\n# Warranty Information","[{\"question\":\"What system information does the manual provide before installation?\",\"answer\":\"It includes performance/electrical data and specifications, dimensional diagrams, and space and location requirements with recommended unit placement.\"},{\"question\":\"What steps are covered for installing the PRO3 top mount packaged refrigeration system?\",\"answer\":\"The manual provides rigging, mounting, inspection, general safety information, and a standard installation procedure.\"},{\"question\":\"How does the manual support commissioning and maintenance?\",\"answer\":\"It explains controller program settings, provides a system troubleshooting chart, lists replacement parts, and includes electrical wiring diagrams.\"}]","Heatcraft Pro 3 Top Mount Installation Manual - Part No. 25001801 - September 2010 | PDF",71]