[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-462561-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-462561-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","headless-screw-fixation-is-associated-with-reduced-hardware-removal-after-tibial-tubercle-osteotomy-a-retrospective-cohort-study","Headless Screw Fixation Is Associated with Reduced Hardware Removal After Tibial Tubercle Osteotomy: A Retrospective Cohort Study","","Symptomatic hardware removal is a leading cause of reoperation after tibial tubercle osteotomy (TTO), with reported removal rates up to 49%. Headless compression screws are proposed as a lower-profile alternative to conventional headed screws, but direct comparisons in TTO for patellofemoral instability remain limited. This retrospective cohort study analyzed 84 patients (94 knees) treated from 2014 to 2024, comparing complication and hardware removal outcomes between headless and headed fixation.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/headless-screw-fixation-is-associated-with-reduced-hardware-removal-after-tibial-tubercle-osteotomy-a-retrospective-cohort-study/462561/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/headless-screw-fixation-is-associated-with-reduced-hardware-removal-after-tibial-tubercle-osteotomy-a-retrospective-cohort-study/462561.png","ImageObject",300,407,{"name":42,"@type":43},"Chumphorn","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-31","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the main clinical problem addressed by the study?","Question",{"text":63,"@type":64},"Symptomatic hardware removal is identified as the most frequent cause of reoperation after tibial tubercle osteotomy (TTO). The study targets whether headless screws can reduce hardware-related complications compared with headed screws.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How was the study designed and who were the participants?",{"text":68,"@type":64},"A retrospective cohort review included 84 patients (94 knees) who underwent TTO between 2014 and 2024. Patients were grouped by fixation type: headless screws (56 knees) versus headed screws (38 knees), with at least one-year follow-up.",{"name":70,"@type":61,"acceptedAnswer":71},"What were the key outcomes comparing headless and headed screws?",{"text":72,"@type":64},"Symptomatic implant removal occurred in 13.2% of the headed group and in none of the headless group (p = 0.001). Reoperation for any reason was also lower in the headless group (3.6% vs. 26.3%, p = 0.002), while functional outcomes were similar between groups.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},462561,1791097682,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":109,"preview_page_count":33,"preview_urls":145},2336475401981,"https://ap-avatar.wpscdn.com/avatar/22000c94efd8d5204d?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786935347598174694","Article  \nHeadless Screw Fixation Is Associated with Reduced Hardware Removal After Tibial Tubercle Osteotomy: A Retrospective Cohort Study  \nOguzhan Uslu  and Ozkan Kose *  \nAcademic Editor: Christian von Rüden  \nReceived: 29 November 2025  \nRevised: 20 December 2025  \nAccepted: 27 December 2025  \nPublished: 28 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \nDepartment of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, 07100 Antalya, Türkiye; [oguzhannuslu@gmail.com](oguzhannuslu@gmail.com)  \n* Correspondence: [drozkankose@hotmail.com](drozkankose@hotmail.com)  \nAbstract  \nBackground/Objectives: Symptomatic hardware removal remains the most frequent cause of reoperation after tibial tubercle osteotomy (TTO), with removal rates reported as high as 49% . Headless compression screws have been proposed as a low-profile alternative to conventional screws to reduce hardware-related morbidity, yet no study has directly compared their use with headed screws in TTO for patellofemoral instability. This study aimed to compare complication rates and the frequency of hardware removal between headless and headed screw fixation in TTO. Methods: A retrospective review was conducted on 84 patients (94 knees) who underwent TTO between 2014 and 2024 . Patients were divided into two groups based on the type of fixation used: headless screws (56 knees) and headed screws (38 knees) . Demographic characteristics, perioperative variables, functional outcomes (Kujala, Lysholm, and Tegner scores), complications, and reoperation rates were compared with a minimum one-year follow-up. Results: No significant differences were found between the groups in terms of baseline demographic and clinical characteristics. Symptomatic implant removal occurred in 13.2% of the headed screw group and in none of the patients in the headless screw group (p = 0.001) . Reoperation for any reason was significantly lower in the headless group (3.6% vs. 26.3%, p = 0.002) . Functional outcomes were similar between groups. Post-hoc power analysis confirmed sufficient statistical power (98.8%) to detect differences in implant removal rates. Conclusions: Headless screw fixation in TTO was associated with significantly lower rates of hardware-related reoperations and painful implant removal, while achieving functional outcomes similar to those with headed screws. Headless screws may represent a preferable fixation method for reducing implant-related complications in TTO.  \nKeywords: tibial tubercle osteotomy; patellofemoral instability; headless compression screw; hardware removal; complication; reoperation  \n1. Introduction  \nAcute patellar dislocations are common in adolescents and often lead to functional limitations, with recurrence affecting nearly one-third of patients at long-term followup [1–3] . Key risk factors for acute and recurrent patellar dislocations include young age, open physes, trochlear dysplasia, patella alta, and an increased tibial tuberosity–trochlear groove (TT–TG) distance [2–4] . The medial patellofemoral ligament (MPFL), which provides approximately half of the soft-tissue restraint against lateral displacement [5], is ruptured in most first-time dislocations, with a prevalence of up to 94.7%[6] .  \nNon-operative treatment maybe considered after a first-time dislocation in the absence of repairable osteochondral injuries; however, recurrent dislocations typically require surgical intervention [7,8] . Surgical management is individualized according to the patient’s anatomical risk factors. The medial patellofemoral ligament reconstruction (MPFLR) is regarded as the cornerstone of surgical management, given the high incidence of MPFL rupture and its pivotal role in medial patellar stability. MPFLR is often supplemented with tibial ","cbCaihY2ZxSnCxT4","https://ap.wps.com/l/cbCaihY2ZxSnCxT4","pdf",1977415,16,"English","# Introduction\n## Acute patellar dislocations and risk factors\n## Role of MPFL reconstruction and adjunct TTO\n## Rationale for headless compression screws\n# Materials and Methods\n## Patients and study design","[{\"question\":\"What is the main clinical problem addressed by the study?\",\"answer\":\"Symptomatic hardware removal is identified as the most frequent cause of reoperation after tibial tubercle osteotomy (TTO). The study targets whether headless screws can reduce hardware-related complications compared with headed screws.\"},{\"question\":\"How was the study designed and who were the participants?\",\"answer\":\"A retrospective cohort review included 84 patients (94 knees) who underwent TTO between 2014 and 2024. Patients were grouped by fixation type: headless screws (56 knees) versus headed screws (38 knees), with at least one-year follow-up.\"},{\"question\":\"What were the key outcomes comparing headless and headed screws?\",\"answer\":\"Symptomatic implant removal occurred in 13.2% of the headed group and in none of the headless group (p = 0.001). Reoperation for any reason was also lower in the headless group (3.6% vs. 26.3%, p = 0.002), while functional outcomes were similar between groups.\"}]","Headless Screw Fixation Is Associated with Reduced Hardware Removal After Tibial Tubercle Osteotomy: A Retrospective Cohort Study | PDF",1790764491,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/dc2f912079018118d4b68f683e3dd4b6.webp",983,1390,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/be7a00238a4a8facb7ea168b8abb4f58.webp",982,1388,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2d12cbfb17080f750d03d468c295ab35.webp",981,1387,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/babaec4e39db658064e83314e1fde617.webp",980,1385]