[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-561902-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-561902-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","he700-di-l-relay-features-and-benefits","HE700 D.I. L. Relay Features and Benefits","","HE700 D.I. L. relay product overview outlining key features and engineering benefits for compact switching applications. Highlights include miniature dual in-line packaging, selectable contact configurations (normally open, normally closed, change-over) and options such as magnetic shielding, diode suppression, diagonal coil, and high-voltage switching. The document also specifies dimensions, PCB layout guidance, ordering/part-number structure, applications list, and detailed electrical, operating, coil, timing, resistance, voltage hold-off, and environmental characteristics at defined temperatures.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/he700-di-l-relay-features-and-benefits/561902/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/he700-di-l-relay-features-and-benefits/561902.png","ImageObject",300,407,{"name":42,"@type":43},"Anna Hans","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-18","2026-10-12",true,{"@type":52,"interactionType":53,"userInteractionCount":26},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What contact options are available for the HE700 D.I. L. relay?","Question",{"text":62,"@type":63},"The relay supports normally open, normally closed, and change-over contacts, with up to 2 normally open contacts depending on the selected model and contact form.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"Which coil voltage options are offered as standard?",{"text":67,"@type":63},"Standard options include 5V, 12V, and 24V coil choices.",{"name":69,"@type":60,"acceptedAnswer":70},"How does the document define the electrical and operating characteristics for HE700 series?",{"text":71,"@type":63},"It provides a table of contact ratings and limits, including power and switching voltage/current, voltage hold-off across open contacts and to coil/shield, insulation resistance ranges, operate/release timing, and environmental requirements such as operating/storage temperatures and vibration/shock resistance.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},561902,1792303671,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},7,40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":26,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":96},5909892332657,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","[www.hamlin.com](www.hamlin.com)  \nHE700 D.I. L. Relay Features and Benefits  \nFeatures  \n• Miniature dual in line package  \n• Choice of normally open, normally closed and change over contacts  \n• High voltage switching option  \n• Up to 2 normally open contacts  \n• Available with 5V, 12V or 24V coil options as standard  \n• Magnetic shield option  \n• Diode suppression option  \n• Diagonal coil option  \nBenefits  \n• One relay, various contacts choices reducing space and cost without compromising flexibility  \n• Lower power coil consumption than competing electromechanical devices.  \n• Hermetically sealed switching contact is immune to the effects of its environment  \n• Transfer moulded package gives maximum component protection  \nApplications  \n• Security  \n• Telecoms  \n• Instrumentation  \n• Process Control  \n• Industrial  \nDIMENSIONS (in) mm  \nFigure 1 HE700 Figure 2 HE751 Figure 3 HE700 (All)  \nTable 1  \n\n| Relay Type | Body Type | l | w | h |\n| --- | --- | --- | --- | --- |\n| HE700 | Transfer Molded | (.750) 19,05 | (.285) 7,24 | (.295) 7,50 |\n|  | External Shield | (.795) 20,19 | (.300) 7,62 | (.305) 7,75 |\n\nHE700 PCB LAYOUT (Bottom View) ORDERING INFORMATION  \nPART NUMBER HE7X X X  \nModel Number HE72-Standard  \nHE75-High Voltage  \nNumber of Contacts 1,2  \nXX XX  \nContact Type Standard Coil  \nA-Form A (SPST-NO) 05-5 Volt  \nB-Form B (SPST-NC) 12-12 Volt  \nC-Form C (SPDT-CO) 24-24 Volt  \nE-Form C (SPDT-CO) alternate foot print 1  \nR-Form C (SPDT-CO) alternate foot print 2  \nEXAMPLE: The HE721A0540 is a 1 Form relay with a 5 Volt coil and external magnetic shield Contact the Hamlin Applications Engineering Department for low profile and other option combinations available.  \nSee next page for: Electrical and Operating Characteristics Description and Coil Characteristics  \nHamlin USA Tel: +1 920 648 3000 • Fax: +1 920 648 3001 • Email: [sales.us@hamlin.com](sales.us@hamlin.com)  \nHamlin UK Tel: +44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: [sales.uk@hamlin.com](sales.uk@hamlin.com)  \nHamlin Germany Tel: +49 (0) 6181 953660 • Fax: +49 (0) 6181 9536666 • Email: [sales.de@hamlin.com](sales.de@hamlin.com)  \nHamectrol France Tel: +33 (0) 1 4687 0202 • Fax: +33 (0) 1 4686 6786 • Email: [sales.fr@hamlin.com](sales.fr@hamlin.com) ISSUE No: 4 DATE: 1/5/3  \n Table 2  HE700 Series  Recognised File \\#E47258  Electrical and Operating Characteristics @ 25 ˚C.  \n\n| Column Number |  |  | 1 | 2 | 3 | 4 |\n| --- | --- | --- | --- | --- | --- | --- |\n| Contact Type |  |  | Form A\u003Cbr>SPST, DPST\u003Cbr>Standard | Form C\u003Cbr>SPDT-CO\u003Cbr>Standard | Form A\u003Cbr>SPST\u003Cbr>High Voltage | Form B\u003Cbr>SPST-NC\u003Cbr>Standard |\n| Relay Types |  |  | HE721, HE722 | HE721C, E, R | HE751 | HE721 |\n| CONTACT RATINGS Contact Hamlin for specific load/life details | Power, Switching\u003Cbr>Voltage, Switching\u003Cbr>Current, Switching Current, Carry | Watt-max.\u003Cbr>Vdc-max. A-max.\u003Cbr>A-max. | 10\u003Cbr>200\u003Cbr>0.5\u003Cbr>1.2 | 5\u003Cbr>175\u003Cbr>0.25\u003Cbr>1.5 | 10\u003Cbr>300\u003Cbr>0.5\u003Cbr>1.2 | 10\u003Cbr>200\u003Cbr>0.5\u003Cbr>1.2 |\n| VOLTAGE HOLD-OFF | Across Open Contacts\u003Cbr>Contacts to Coil\u003Cbr>Coil to E. Shield\u003Cbr>Between Isolated Terminals | Vdc-min.\u003Cbr>Vac-min.\u003Cbr>Vac-min.\u003Cbr>Vac-min. | 250\u003Cbr>500\u003Cbr>150\u003Cbr>500 | 200\u003Cbr>500\u003Cbr>150\u003Cbr>N/A | 450\u003Cbr>2500\u003Cbr>N/A\u003Cbr>N/A | 250\u003Cbr>500\u003Cbr>N/A\u003Cbr>N/A |\n| RESISTANCE | Contact, Initial\u003Cbr>Insulation: Across Open Contacts Between Isolated Terminals | Ω -max.\u003Cbr>Ω -min.\u003Cbr>Ω -min. | 0.150\u003Cbr>1010\u003Cbr>1010 | 0.200\u003Cbr>109\u003Cbr>1010 | 0.150\u003Cbr>1010\u003Cbr>1010 | 0.150\u003Cbr>1010\u003Cbr>1010 |\n| TIMING | Operate Time\u003Cbr>Release Time | ms-max.\u003Cbr>ms-max. | 1.0\u003Cbr>1.0 | 3.0\u003Cbr>3.0 | 1.0\u003Cbr>1.0 | 1.0\u003Cbr>1.0 |\n| ENVIRONMENTAL | Temperature, Operating\u003Cbr>Temperature, Storage\u003Cbr>Vibration Resistance\u003Cbr>Shock Resistance | °C\u003Cbr>°C\u003Cbr>G-max. 10-2000 Hz. G-max. 11 ms,⁄1 2 sine | -40 to +85\u003Cbr>-40 to +105\u003Cbr>20\u003Cbr>50 | -40 to +85\u003Cbr>-40 to +105\u003Cbr>20\u003Cbr>50 | -20 to +85\u003Cbr>-40 to +105\u003Cbr>20\u003Cbr>50 | -40 to +85\u003Cbr>-40 to +105\u003Cbr>20\u003Cbr>50 |\n\n Table 3  HE700 Series Miniature Relay  Coil Characteristics @ 25˚C.  ","cbCaiaYNhpcghLwy","https://ap.wps.com/l/cbCaiaYNhpcghLwy","pdf",533072,"English","# Features\n# Benefits\n# Applications\n# Dimensions\n# HE700 PCB Layout (Bottom View)\n# Ordering Information\n# Electrical and Operating Characteristics @ 25 ˚C\n# Coil Characteristics @ 25˚C","[{\"question\":\"What contact options are available for the HE700 D.I. L. relay?\",\"answer\":\"The relay supports normally open, normally closed, and change-over contacts, with up to 2 normally open contacts depending on the selected model and contact form.\"},{\"question\":\"Which coil voltage options are offered as standard?\",\"answer\":\"Standard options include 5V, 12V, and 24V coil choices.\"},{\"question\":\"How does the document define the electrical and operating characteristics for HE700 series?\",\"answer\":\"It provides a table of contact ratings and limits, including power and switching voltage/current, voltage hold-off across open contacts and to coil/shield, insulation resistance ranges, operate/release timing, and environmental requirements such as operating/storage temperatures and vibration/shock resistance.\"}]","HE700 D.I. L. Relay Features and Benefits | PDF",1791807226]