[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663452-105":59,"doc-detail-663452-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hanszen-college-wing-telecom-drawings-cabling-electrical-and-grounding-notes","Hanszen College Wing Telecom Drawings - Cabling, Electrical, and Grounding Notes","","Telecom room and communications infrastructure installation notes for Hanszen College Wing, covering data outlet types and cabling destinations for wired outlets, wireless access points, IP security cameras, wall phones, display outlets, and digital signage infrastructure. Includes coordination-only guidance for telecom room layouts, plywood wall treatments, patch panel quantity clarifications, and requirements for cable support and cable management. Specifies electrical receptacle placement, dedicated circuits for equipment racks, power and generator backup installation, CAT6A termination practices, cable length limits, coaxial and video surveillance cabling, grounding and bonding methods, and labeling standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hanszen-college-wing-telecom-drawings-cabling-electrical-and-grounding-notes/663452/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hanszen-college-wing-telecom-drawings-cabling-electrical-and-grounding-notes/663452.png","ImageObject",300,407,{"name":92,"@type":93},"sagouaw","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the listed data outlet and camera outlet cabling requirements?","Question",{"text":112,"@type":113},"The notes specify CAT6A cabling counts and placement for data outlets, wireless access points, and ceiling/wall outlets for IP security cameras. Display outlets require termination to display back boxes, and digital signage calls for infrastructure only.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What termination and cabling rules apply to CAT6A and station cabling length?",{"text":117,"@type":113},"All category 6A jack inserts must be terminated to the 568-B wiring scheme. Horizontal data cabling must use specified 23 AWG CAT6A 4PR UTP cables, and no horizontal cable may exceed 295 feet without written owner architect/engineer approval.",{"name":119,"@type":110,"acceptedAnswer":120},"How should grounding and bonding be implemented in telecom rooms?",{"text":121,"@type":113},"All metal racks, frames, cabinets, and equipment enclosures must be bonded together using green insulated copper wire to achieve a common ground potential. Grounding surfaces must be prepared for effective contact by removing paint or coatings, and required bonding components such as star washers and routing brackets must be installed per the notes.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663452,1793227839,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":56,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},3985747862151,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","| \u003Cbr>xD | DATA OUTLET, (x) NUMBER OF CAT6A CABLE UNLESS OTHERWISE SPECIFIED. MOUNTED +18\" AFF UNLESS OTHERWISE SPECIFIED. |\n| --- | --- |\n| \u003Cbr>WAP | DATA OUTLET FOR WIRELESS ACCESS POINT, (2) CAT6A CABLE UNLESS OTHERWISE SPECIFIED. MOUNTED 8'-6\" AFF UNLESS OTHERWISE SPECIFIED. |\n| \u003Cbr>CAM | CEILING DATA OUTLET FOR IP SECURITY CAMERA, (1) CAT6A CABLE UNLESS OTHERWISE SPECIFIED. REFER TO SCHEDULE ON PLANS FOR MOUNTING ELEVATION. |\n| \u003Cbr>CAM | DATA OUTLET FOR IP SECURITY CAMERA, (1) CAT6A CABLE UNLESS OTHERWISE SPECIFIED. REFER TO SCHEDULE ON PLANS FOR MOUNTING ELEVATION. |\n| \u003Cbr>WP | WALL PHONE, (1) CAT6A CABLE UNLESS OTHERWISE SPECIFIED. MOUNTED +48\" AFF UNLESS OTHERWISE SPECIFIED. |\n| \u003Cbr>xD TV | DATA OUTLET FOR DISPLAY, (x) NUMBER OF CAT6A CABLE UNLESS OTHERWISE SPECIFIED. TERMINATE TO DISPLAY BACK BOX. MOUNTED +60\" AFF UNLESS OTHERWISE SPECIFIED. |\n| \u003Cbr>XX\" DSD | DIGITAL SIGNAGE DISPLAY. PROVIDE INFRASTRUCTURE ONLY. DISPLAY AND MOUNT OFOI. |\n\nCOMMUNICATIONS ROOMS  \n1. TELECOM ROOM LAYOUTS AND EQUIPMENT ARE SHOWN FOR COORDINATION AND INFORMATIONAL PURPOSES ONLY.  \n2. 8’ H X 4’W X ¾’ T GRADE ACX PAINTED PLYWOOD SHALL BE PLACED ON DESIGNATED WALLS OF THE TELECOM ROOMS. PLYWOOD SHALL BE PAINTED TWO COATS OF FIRE RETARDENT WHITE PAINT.  \n3. GRAPHIC REPRESENTATION OF PATCH PANELS AND TERMINAL BLOCKS DO NOT REPRESENT EXACT QUANTITIES. CONTRACTOR SHALL PROVIDE SUFFICIENT QUANTITIES FOR ALL CABLING, PLUS 20% .  \n4. FURNISH AND INSTALL VELCRO CABLE SUPPORT, CABLE MANAGEMENT AND ASSOCIATED HARDWARE WITHIN TELECOMMUNICATIONS ROOMS.  \n5. CONTRACTOR TO PROVIDE AUTOCAD FLOOR PLAN AS-BUILT ON \"D\" SIZE PAPER, LAMINATED WITH PLASTIC AND MOUNTED BEHIND CUT PLEXIGLASS ON THE WALL IN EACH TELECOM ROOM. REFERENCE TELECOM ROOM ELEVATIONS FOR AS-BUILT PLACEMENT.  \nELECTRICAL  \n1. FOR SPECIFIC POWER AND RECEPTACLE REQUIREMENTS IN THE PROJECT REFERENCE ELECTRICAL SPECIFICATIONS AND DRAWINGS AND VERIFY WITH COMMUNICATION SPECIFICATIONS AND DRAWINGS. REPORT TO GC DISCREPANCIES PRIOR TO PURCHASE OR INSTALLATION.  \n2. PROVIDE A MINIMUM OF ONE (1) DUPLEX RECEPTACLE FOR EACH INFORMATION OUTLET (I/O) INSTALLED THAT IS NOT LOCATED WITHIN 3'OF A DUPLEX ELECTRICAL OUTLET.  \n3. PROVIDE DEDICATED RECEPTACLE CIRCUITS LOCATED ON OR NEAR EACH EQUIPMENT RACK LOCATED IN THE COMMUNICATIONS ROOMS. REFER TO ELECTRICAL DOCUMENTS FOR SPECIFICS.  \n4. ELECTRICAL CONTRACTOR SHALL INSTALL NORMAL AND GENERATOR BACK-UP POWER AS REQUIRED.  \nCOMMUNICATIONS CABLE  \n1. CABLING CONTRACTOR MUST BE A CERTIFIED INSTALLER AND BE ABLE TO PROVIDE MANUFACTURER WARRANTY.  \n2. CONTRACTOR SHALL TERMINATE ALL CATEGORY 6A JACK INSERTS TO 568-B WIRING SCHEME.  \n3. HORIZONTAL DATA CABLING SHALL CONSIST 23 AWG CAT6A 4PR UTP CABLES TO EACH DATA OUTLET.  \n4. WIRELESS OUTLET LOCATIONS SHALL CONSIST OF TWO (2) 23 AWG CAT6A 4PR UTP CABLES TO EACH ACCESS POINT.  \n5. NO HORIZONTAL CABLE SHALL BE LONGER THAN 295 FEET. IF THE CONTRACTOR BELIEVES ANY STATION CABLE WILL EXCEED THE 295 FEET LIMIT WRITTEN APPROVAL FROM THE OWNER'S ARCHITECT/ENGINEER WILL BE REQUIRED PRIOR TO INSTALLATION.  \n6. HORIZONTAL DATA CABLING SHALL TERMINATE ON RACK MOUNTED ANGLED 48-PORT PATCH PANELS. LOCATED IN TELECOM ROOM, AND ON JACK INSERTS AT THE OUTLET.  \n7. CONTRACTOR TO PROVIDE LACING BARS TO RESTRAIN CABLES AND TO PREVENT STRAINING CONNECTIONS.  \n8. COMMUNICATIONS CABLE SHALL NOT BE PAINTED.  \n9. PROVIDE ALL NECESSARY MEANS TO PROTECT ALL DATA/VOICE/FIBER CABLING AND JACKS/PORTS FROM MECHANICAL DAMAGE AND DUST DURING CONSTRUCTION.  \n10. CONTRACTOR TO PROVIDE SELF-ADHESIVE VINYL OR VINYL-CLOTH WRAPAROUND TAPE MARKERS, MACHINE PRINTED WITH ALPHANUMERIC CABLE DESIGNATIONS PER ANSI/TIA-607B STANDARDS WITH APPROVAL FROM OWNER IT.  \n11. CONTRACTOR TO PROVIDE PROPER RATED CABLE TYPE PER INSTALLATION TYPE OSP, RISER OR PLENUM.  \n12. ALL CABLING INSTALLED UNDERGROUND IN CONCRETE SLABS, INDIRECT CONTACT WITH THE EARTH, LOCATIONS SUBJECT TO SATURATION WITH LIQUIDS AND UNPROTECTED LOCATIONS EXPOSED TO WEATHER SHALL BE CONSTRUCTED WIT","cbCait70BavtovZo","https://ap.wps.com/l/cbCait70BavtovZo","pdf",8216020,"English","# Communications Rooms\n## Electrical\n## Communications Cable\n## Grounding and Bonding","[{\"question\":\"What are the listed data outlet and camera outlet cabling requirements?\",\"answer\":\"The notes specify CAT6A cabling counts and placement for data outlets, wireless access points, and ceiling/wall outlets for IP security cameras. Display outlets require termination to display back boxes, and digital signage calls for infrastructure only.\"},{\"question\":\"What termination and cabling rules apply to CAT6A and station cabling length?\",\"answer\":\"All category 6A jack inserts must be terminated to the 568-B wiring scheme. Horizontal data cabling must use specified 23 AWG CAT6A 4PR UTP cables, and no horizontal cable may exceed 295 feet without written owner architect/engineer approval.\"},{\"question\":\"How should grounding and bonding be implemented in telecom rooms?\",\"answer\":\"All metal racks, frames, cabinets, and equipment enclosures must be bonded together using green insulated copper wire to achieve a common ground potential. Grounding surfaces must be prepared for effective contact by removing paint or coatings, and required bonding components such as star washers and routing brackets must be installed per the notes.\"}]","Hanszen College Wing Telecom Drawings - Cabling, Electrical, and Grounding Notes | PDF",48]