[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-653105-105":59,"doc-detail-653105-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hamilton-c6-intellivent-asv-operators-manual-class-iii-software-version-20x","HAMILTON-C6 - INTELLiVENT-ASV Operator's Manual - Class III - Software Version 2.0.x","","Operator’s manual for the INTELLiVENT-ASV system associated with HAMILTON-C6 ventilation equipment. Covers software version 2.0.x and provides dated publication and revision information, including copyright and distribution restrictions. Describes required operation by trained professionals, responsibilities and warranty scope, misuse/non-authorized parts liability limits, and instructions for handling returned goods and disposal. Includes guidance on device navigation, intended use, clinical indications and contraindications, setup of ventilation and patient data, control management modes, alarm limit adjustments, monitoring views, and alarm troubleshooting.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hamilton-c6-intellivent-asv-operators-manual-class-iii-software-version-20x/653105/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hamilton-c6-intellivent-asv-operators-manual-class-iii-software-version-20x/653105.png","ImageObject",300,407,{"name":92,"@type":93},"404brain","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to operate or service the equipment described in the manual?","Question",{"text":112,"@type":113},"The equipment must be operated, serviced, or upgraded only by trained professionals.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What responsibilities and limits of liability does Hamilton Medical AG state?",{"text":117,"@type":113},"Hamilton Medical AG states sole responsibility per the limited warranty in the device Operator’s Manual and disclaims liability for losses or damage arising from misuse, use of non-Hamilton parts, or altered serial numbers.",{"name":119,"@type":110,"acceptedAnswer":120},"What topics are covered in Chapter 1 for INTELLiVENT-ASV?",{"text":121,"@type":113},"Chapter 1 covers overview and intended use, indications/contraindications, navigation of windows and controls, preparation and settings for ventilation, monitoring views, troubleshooting alarms, and management of minute volume (%MinVol).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},653105,1793139856,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},1099529839291,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","INTELLiVENT-ASV Operator's Manual HAMILTON-C6  \n 160758, 160768, 160769, 160770, 160771, 160772, 10182384, 10182385, 10182387, 10182388  \nSoftware version 2.0.x 10172294/00 | 2024-09-30  \nOperator's Manual  \nINTELLiVENT-ASV  \n2024-09-30  \n10172294/00  \n© 2024 Hamilton Medical AG. All rights reserved. Printed in Switzerland.  \nNo part of this publication may be reproduced, stored in a database or retrieval system, or transmitted in any form or by any means, electronic, mechanical, or by photocopying, recording, or otherwise, without prior written permission of Hamilton Medical AG.  \nThis document may be revised, replaced, or made obsolete by other documents by Hamilton Medical AG at any time and without notice. Ensure that you have the most current applicable version of this document; if in doubt, contact the technical support department of Hamilton Medical AG, Switzerland. While the information set forth herein is believed to be accurate, it isnot a substitute for the exercise of professional judgment.  \nNothing in this document shall limit or restrict in any way Hamilton Medical AG’s right to revise or otherwise change or modify the equipment (including its software) described herein, without notice. In the absence of an express, written agreement to the contrary, Hamilton Medical AG has no obligation to furnish any such revisions, changes, or modifications to the owner or user of the equipment (including software) described herein.  \nThe equipment must be operated, serviced, or upgraded only by trained professionals. Hamilton Medical AG’s sole responsibility with respect to the equipment and its use is as stated in the limited warranty provided in the device Operator’s Manual.  \nHamilton Medical AG shall not be liable for any loss, cost, expense, inconvenience, or damage that may arise out of misuse of the product, or if non-Hamilton Medical AG parts were used when replacing parts, or if serial numbers were amended, deleted, or removed.  \nIf returning parts to Hamilton Medical AG, be sure to use the standard Hamilton Medical returned goods authorization (RGA) procedure. Disposal of parts shall follow all local, state, and federal regulation with respect to environmental protection.  \nHamilton Medical AG will make available, on request, circuit diagrams, component parts lists, descriptions, calibration instructions, or other information that will assist appropriately trained personnel to repair those parts of the equipment designated by Hamilton Medical AG to be repairable.  \nFor all proprietary and third-party trademarks used by Hamilton Medical AG, see [www.hamilton-medical.com/trademarks](www.hamilton-medical.com/trademarks).  \nManufacturer  \nHamilton Medical AG Via Crusch 8, 7402 Bonaduz Switzerland  \nPhone: +41 (0) 58 610 10 20 [info@hamilton-medical.com](info@hamilton-medical.com)[ ](info@hamilton-medical.com)[www.hamilton-medical.com](www.hamilton-medical.com)  \nTable of Contents  \nChapter 1 INTELLiVENT-ASV ............................................................... 13  \n1.1 Overview ................................................................................................... 14  \n1.2 Intended use............................................................................................ 15  \n1.3 Indications and contraindications for use ........................................ 15  \n1.4 Navigating the windows and controls ............................................... 17  \n1.5 Preparing for ventilation with INTELLiVENT-ASV ............................. 17  \n1.6 Specifying INTELLiVENT-ASV settings ................................................ 18  \n1.6.1 Specifying patient data ................................................................. 20  \n1.6.2 Selecting the INTELLiVENT-ASV mode ...................................... 20  \n1.6.3 Selecting control management options (Auto/Manual) ........ 21  \n1.6.4 Adjusting for Specific conditions ................................................ 23  \n1.6.5 Enabling","cbCaikQ5HqO9MrFX","https://ap.wps.com/l/cbCaikQ5HqO9MrFX","pdf",3609066,136,"English","# Chapter 1 INTELLiVENT-ASV\n## 1.1 Overview\n## 1.2 Intended use\n## 1.3 Indications and contraindications for use\n## 1.4 Navigating the windows and controls\n## 1.5 Preparing for ventilation with INTELLiVENT-ASV\n## 1.6 Specifying INTELLiVENT-ASV settings\n## 1.7 Monitoring INTELLiVENT-ASV\n## 1.8 Troubleshooting alarms\n## 1.9 Management of minute volume (%MinVol)\n## 1.9.1 Management of %MinVol, passive patient","[{\"question\":\"Who is allowed to operate or service the equipment described in the manual?\",\"answer\":\"The equipment must be operated, serviced, or upgraded only by trained professionals.\"},{\"question\":\"What responsibilities and limits of liability does Hamilton Medical AG state?\",\"answer\":\"Hamilton Medical AG states sole responsibility per the limited warranty in the device Operator’s Manual and disclaims liability for losses or damage arising from misuse, use of non-Hamilton parts, or altered serial numbers.\"},{\"question\":\"What topics are covered in Chapter 1 for INTELLiVENT-ASV?\",\"answer\":\"Chapter 1 covers overview and intended use, indications/contraindications, navigation of windows and controls, preparation and settings for ventilation, monitoring views, troubleshooting alarms, and management of minute volume (%MinVol).\"}]","HAMILTON-C6 - INTELLiVENT-ASV Operator's Manual - Class III - Software Version 2.0.x | PDF",1792885636,343]