[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-398478-105":59,"doc-detail-398478-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","group-fit-test-mode-reduce-fit-test-hours","Group Fit Test Mode - Reduce Fit Test Hours","","Group Fit Test Mode streamlines respirator fit testing by enabling up to four instruments to run separate tests from a single control screen. It reduces required test hours and the number of fit test administrators, saving personnel time and lowering labor costs. Tests remain independent with different start/stop times and respirator types, while one administrator can monitor up to four instruments. Personalized screens guide wearers through the process, and the mode is available with PortaCount Respirator FitTester models 8040 and 8048.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/group-fit-test-mode-reduce-fit-test-hours/398478/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/group-fit-test-mode-reduce-fit-test-hours/398478.png","ImageObject",300,407,{"name":92,"@type":93},"anakgang17","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02","2026-09-27",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"How does Group Fit Test Mode reduce fit test hours and staffing needs?","Question",{"text":113,"@type":114},"It lets users run four separate fit tests at the same time from one control screen. This reduces the number of hours and test administrators needed while improving efficiency and lowering overhead.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Can each person test different respirator types in the same Group Fit session?",{"text":118,"@type":114},"Yes. Different instruments can be set up for different respirator types (for example, N95 on one unit and full-face on another), and each test can have different start/stop times and respirator types.",{"name":120,"@type":111,"acceptedAnswer":121},"What PortaCount equipment is required to use Group Fit Test Mode?",{"text":122,"@type":114},"Group Fit Test Mode works only with fourth generation PortaCount Fit Tester models 8040 and 8048. It also connects up to four instruments using a simple USB hub.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},398478,1790826133,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":24,"preview_page_count":4},962090883568,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Group Fit Test Mode  \nMore tests done in less time with the PortaCount™ Respirator fit tester  \nReduce fit test hours by 50% or more  \nGroup Fit Test Mode  \nReduces the number of hours and test administrators needed to fit test your staff.  \nFor fit test administrators, Group Fit Testing Mode saves personnel hours by allowing four people to be tested at the same time. That means efficiency and reduced overhead.  \n▪ Save hours and labor costs by administering more tests at the same time  \n▪ Each fit test is independent. Start and stop times and respirator types can be different for each test  \n▪ One administrator can monitor up to four instruments from a single control screen  \n▪ Personalized screens separately guide respirator wearers through the fit test  \n▪ Available with the new PortaCount™ Respirator FitTester models 8040 and 8048  \n[tsi.com/portacount4](tsi.com/portacount4)  \nor call technical services at 1-800-874-2811  \nEstimated time saved with and without Group Fit Test Mode using PortaCount™ 8048  \nGroup Fit Test Mode How It Works  \nGroup Fit Test Mode allows users to connect up to four instruments using a simple USB hub and run four separate fit tests from one control screen.  \nCan I test more than one respirator type at a time?  \nYes. For example, one unit could be set up for testing employees on N95s respirator while another can be set up with a full-face respirator, etc…  \nCan I use Group FitTest Mode with fewer than four PortaCounts?  \nYou can use Group Fit Test Mode with fewer than four instruments, or even a single instrument.  \nDoes it work for any Protocol?  \nPortaCounts can fit test any respirator type, make, model or rating.  \nHow many administrators do I need?  \nYou only need one administrator.  \nCan I also use my old PortaCount™ with a new instrument for group fit testing?  \nGroup Fit Test Mode works only with fourth generation PortaCount™ Fit Tester models 8040 and 8048.  \nWhere is the data from each PortaCount™ saved?  \nDo I have to keep data separate for each instrument?  \nAll records are consolidated into a single database, accessed by the primary computer running FitPro™ Ultra Fit Test Software.  \nHow do I get started?  \nContact your current sales representative, visit [http://www.tsi.com/portacount4](http://www.tsi.com/portacount4)  \nor call technical services at 1-800-874-2811  \nTSI, and the TSI logo are registered trademarks of TSI Incorporated in the United States and may be protected under other country’s trademark registrations.  \nP/N 5002189 Rev C ©2024 TSI Incorporated Printed in the U. S. A.","cbCaitM8rE2NmkD8","https://ap.wps.com/l/cbCaitM8rE2NmkD8","pdf",1308222,"English","# Group Fit Test Mode Overview\n## Key Benefits and Efficiency\n## How It Works\n## Setup and Compatibility Questions\n## Data Handling and Administration\n## Getting Started","[{\"question\":\"How does Group Fit Test Mode reduce fit test hours and staffing needs?\",\"answer\":\"It lets users run four separate fit tests at the same time from one control screen. This reduces the number of hours and test administrators needed while improving efficiency and lowering overhead.\"},{\"question\":\"Can each person test different respirator types in the same Group Fit session?\",\"answer\":\"Yes. Different instruments can be set up for different respirator types (for example, N95 on one unit and full-face on another), and each test can have different start/stop times and respirator types.\"},{\"question\":\"What PortaCount equipment is required to use Group Fit Test Mode?\",\"answer\":\"Group Fit Test Mode works only with fourth generation PortaCount Fit Tester models 8040 and 8048. It also connects up to four instruments using a simple USB hub.\"}]","Group Fit Test Mode - Reduce Fit Test Hours | PDF",1790481685]