[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-353704-105":59,"doc-detail-353704-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","graphene-enhanced-non-hermitian-thue-morse-metamaterial-sensor-exploiting-exceptional-point-for-cancer-biomarker-detection","Graphene-enhanced non-Hermitian Thue-Morse metamaterial sensor exploiting exceptional point for cancer biomarker detection","","Presents a one-dimensional photonic-crystal biosensor using a Thue–Morse quasi-periodic structure with parity–time (PT) symmetry and exceptional point (EP) engineering to improve cancer biomarker detection. Alternating porous silicon gain–loss layers combined with graphene nanolayers provide strong optical confinement and resonance sharpening near EP conditions. A parametric study selects graphene chemical potential and relaxation time (0.408 eV, 0.5 ps), achieving sensitivity of 1054 nm/RIU and a minimum detection limit of 9.875 × 10−4 RIU. Results show graphene-layer scaling effects on porosity and enhanced field confinement, supported by fabrication-tolerance robustness for practical label-free sensing.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/graphene-enhanced-non-hermitian-thue-morse-metamaterial-sensor-exploiting-exceptional-point-for-cancer-biomarker-detection/353704/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/graphene-enhanced-non-hermitian-thue-morse-metamaterial-sensor-exploiting-exceptional-point-for-cancer-biomarker-detection/353704.png","ImageObject",300,407,{"name":92,"@type":93},"Asher","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-22",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What sensing concept drives the proposed biosensor’s improved performance?","Question",{"text":113,"@type":114},"The design uses a non-Hermitian parity–time (PT) symmetric structure engineered around exceptional points (EPs), where operation near EPs can strongly amplify spectral response to small perturbations.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does graphene contribute to device sensitivity and detection limits?",{"text":118,"@type":114},"Graphene nanolayers integrated with porous silicon gain–loss layers enhance optical confinement and resonance sharpening near EP conditions, enabling high sensitivity (1054 nm/RIU) and a minimum detection limit of 9.875 × 10−4 RIU.",{"name":120,"@type":111,"acceptedAnswer":121},"What do the parametric study results indicate about optimal graphene parameters?",{"text":122,"@type":114},"The study identifies an optimal graphene chemical potential of 0.408 eV and relaxation time of 0.5 ps, corresponding to the reported maximum sensitivity.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},353704,1790423743,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},687197207639,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nGraphene-enhanced non-Hermitian Thue–Morse metamaterial sensor exploiting exceptional point for cancer biomarker detection  \nAli Mohammadpour􀀍, Ali Soltani Vala & Jamal Barvestani  \nWe present a one-dimensional photonic crystal biosensor based on aThue–Morse quasi-periodic structure incorporating parity–time (PT) symmetry and exceptional point (EP) engineering for enhanced cancer detection. By integrating alternating porous silicon gain–loss layers with graphene nanolayers, the proposed design achieves strong optical confinement and pronounced resonance sharpening near EP conditions. A systematic parametric study identified the optimal graphene chemical potential and relaxation time as 0.408 eV and 0.5 ps, respectively, leading to a maximum sensitivity of 1054 nm/RIU and a minimum detection limit of 9.875 × 10− 4 RIU. Moreover, the analysis reveals that increasing the number of graphene layers results in a progressive enhancement insensitivity accompanied by a reduction in the optimal porosity percentage, highlighting the strong influence of graphene-induced field confinement on device performance. These results surpass those of conventional one-dimensional biosensors, demonstrating the combined advantages of PT symmetry and graphene-assisted field enhancement. Fabrication tolerance analysis confirmed the structural robustness, underscoring its potential for practical implementation. Overall, the findings establish PT-symmetric Thue–Morse photonic crystals as a versatile platform for ultra-sensitive, label-free biomedical sensing, paving the way for next-generation optical diagnostic technologies.  \nKeywords Cancer cells, Exceptional points, Graphene, Parity-time symmetry, Refractive index, Sensitivity, Thue-Morse sequence  \nEarly, label-free, and high-sensitivity detection of cancer cells and biomarkers is a continuing priority for biomedical diagnostics and point-of-care testing. Optical biosensors built from engineered photonic structures especially one-dimensional (1D) photonic crystals (PhCs) are attractive because their layered geometries offer strong field confinement, easily measurable spectral signatures (resonances, reflection/transmission features), and straightforward integration with silicon-based fabrication and microfluidics. Defect modes introduced into 1D PhCs produce narrow, highly localised resonances whose spectral position is susceptible to changes of the local refractive index, a property widely exploited in optical biosensing1,2. Recent progress in plasmonic and photonic biosensing has led to the development of a broad class of high-performance SPR-based sensor configurations. Several recent studies have demonstrated that integrating SPR with specially-engineered photonic crystal fibers (PCFs), kagome-lattice hollow-core structures, and external-metal-deposition geometries can significantly enhance refractive-index sensing performance for a wide range of biological and chemical analytes. For instance, hollow-core kagome PCF-SPR sensors have achieved extremely high wavelength sensitivities for blood-related biomarkers under dual-polarization excitation. Comprehensive reviews of PCF-SPR architectures further highlight their versatility, structural tunability, and ability to detect biomolecules such as glucose, cholesterol, DNA, proteins, and cancer cells with improved field confinement and plasmonic interaction strength. Recent designs using square-lattice PCFs with external metal deposition have also achieved high sensitivity and demonstrated strong linearity and robust operation in complex sensing environments, with emerging directions incorporating machine-learning-assisted optimization. In parallel, optical biosensing technologies, including SPR, LSPR, Raman-based sensors, photonic-waveguide platforms, and fiber-optic configurations have been extensively employed for cancer biomarker detection owing to their high precision,","cbCairlx1mMdQ3UI","https://ap.wps.com/l/cbCairlx1mMdQ3UI","pdf",5400054,22,"English","# Introduction\n## 1D photonic crystal biosensors and defect-mode sensing\n## SPR/LSPR and photonic-crystal hybrid approaches for cancer biomarkers\n## Non-Hermitian PT symmetry and exceptional-point sensing\n## Quasi-periodic Thue–Morse structures for sharp resonances and field enhancement","[{\"question\":\"What sensing concept drives the proposed biosensor’s improved performance?\",\"answer\":\"The design uses a non-Hermitian parity–time (PT) symmetric structure engineered around exceptional points (EPs), where operation near EPs can strongly amplify spectral response to small perturbations.\"},{\"question\":\"How does graphene contribute to device sensitivity and detection limits?\",\"answer\":\"Graphene nanolayers integrated with porous silicon gain–loss layers enhance optical confinement and resonance sharpening near EP conditions, enabling high sensitivity (1054 nm/RIU) and a minimum detection limit of 9.875 × 10−4 RIU.\"},{\"question\":\"What do the parametric study results indicate about optimal graphene parameters?\",\"answer\":\"The study identifies an optimal graphene chemical potential of 0.408 eV and relaxation time of 0.5 ps, corresponding to the reported maximum sensitivity.\"}]","Graphene-enhanced non-Hermitian Thue-Morse metamaterial sensor exploiting exceptional point for cancer biomarker detection | PDF",1790106836,55,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ce4586ce0f5f694c06529b07193ec2e6.webp",983,1291,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/cfa776a4879d05bac7a5ceafeec871a5.webp",982,1290,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/67342e5628a73562e4ef803cdb757304.webp",981,1289,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/30ea772d5a693e1597c5487af91ea01a.webp",980,1287]