[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-608513-105":59,"doc-detail-608513-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","granita-slush-machine-ipro-operators-manual-june-2021-revision-11","GRANITA SLUSH MACHINE IPro OPERATOR’S MANUAL - June 2021 Revision 11","","Operator’s manual for the GRANITA SLUSH MACHINE IPro, published by CRATHCO (June 2021, revision 11). Provides safety-focused guidance for installation and start-up, including warnings on proper use, operator vs. service personnel responsibilities, handling and lifting precautions, and transport storage requirements. Includes an index of technical specifications, positioning, power connection, start-up procedures, control boards, operating instructions, cleaning and sanitizing, maintenance, troubleshooting, wiring diagrams, and exploded views for multiple IPro models.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/granita-slush-machine-ipro-operators-manual-june-2021-revision-11/608513/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/granita-slush-machine-ipro-operators-manual-june-2021-revision-11/608513.png","ImageObject",300,407,{"name":92,"@type":93},"Ben ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-21","2026-10-17",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is the manual intended for, and what parts apply to servicemen only?","Question",{"text":112,"@type":113},"The manual addresses operators for daily equipment use and servicemen qualified for installation and/or maintenance. Sections specifically aimed at servicemen are indicated accordingly.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What precautions are required during transport before start-up?",{"text":117,"@type":113},"Keep the device upright to prevent compressor oil from entering the cooling circuit. If transported in another position, return it to the correct position at least twenty minutes before start-up procedures.",{"name":119,"@type":110,"acceptedAnswer":120},"What does the manual warn about regarding machine use and installation location?",{"text":121,"@type":113},"Use must match the designed purpose, and improper use may cause damage. The equipment is not intended for outdoor use, must not be installed where water jets are used, and should be installed where qualified staff can control it.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},608513,1792409993,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},2336478951081,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","GRANITA  \nSLUSH MACHINE  \nIPro  \nOPERATOR’S MANUAL  \nDate of issue: June, 2021 Revision: 11 Pg. : 1/56  \nDear Customer, We would like to congratulate you for choosing this high-quality product, that will certainly meet all your expectations. We thank you for the preference reserved to our company and we invite you to carefully read the following instruction manual before machine’s start up.  \nPublished by:  \nCRATHCO  \n4003 Collins Lane  \nLouisville, KY 40245  \n800.695.4500  \nEdition: 06/2021  \nRevision: 11  \n© 2021 – Crathco TK,AR  \nAll copying rights are reserved to CRATHCO; copying, even partial, is illegal.  \nThe descriptions and illustrations refer to the specific machine at issue. Crathco reserves the right to modify at anytime the equipment for mass production.  \nThis manual:  \n- is integral part of the supply and must be carefully read, in order to be properly used, in compliance with the essential safety requirements;  \n-has been drafted by following the dispositions 2006/42/CE and reports the technical information that are necessary to correctly run all the procedures, under safety conditions;  \n-must be carefully kept (protected by a transparent, watertight wrapping, in order to avoid any damage) and must go with the machine during its life, including potential changes of ownership. In case of loss or damage, it’s possible to ask for a copy to CRATHCO, pointing out the information stated on the identification label;  \nCRATHCO declines all responsibility for a wrong usage of the machine and/or damages caused by operations not provided for in this manual. .  \nDate of issue: June, 2021 Revision: 11 Pg. : 2/56  \nINDEX  \n1. IMPORTANT WARNINGS AND ADVICES ......................................... 4  \n2. EQUIPMENT KIT............................. 4  \n3. TRANPORT TIPS .............................. 4  \n4. LIFTING TIPS.................................... 4  \n5. TECHNICAL SPECIFICATIONS ..... 5  \n6. POSITIONING ................................... 6  \n7. CONNECTION TO THE POWER SUPPLY MAINS .............................. 7  \n8. START-UP PROCEDURES .............. 8  \n9. ELECTRONIC CONTROL BOARD 9  \nManual mode .......................................... 9  \nAutomatic mode ................................... 10  \nSetting mode ......................................... 10  \n10.MECHANICAL CONTROL BOARD......................................................... 14  \n11.OPERATING INSTRUCTIONS...... 15  \n12.DAILY CLEANING AND SANITIZING PROCEDURES ....... 16  \n13.SPECIAL MAINTENTANCE ......... 22  \nCondenser cleaning ..............................22  \nControl and replacement of seals .........23  \nWinter storage ......................................23  \n14.DISCLAIMER .................................. 23  \n15.TROUBLESHOOTING GUIDE ......24  \n16.WIRING DIAGRAM ....................... 26  \n17. EXPLODED VIEW...........................29  \nI-PRO-2E............................................29  \nI-PRO2-E w/ LED PANEL................32  \nI-PRO2-M w/ TIMER........................35  \nI-PRO2-M w/ LED PANEL...............38  \nI-PRO3-E............................................41  \nI-PRO3-E w/ LED PANEL...............44  \nI-PRO3-M w/ TIMER........................47  \nI-PRO3-M w/ LED PANEL...............50  \n18. PLANNED MAINTAINENCE KIT  \nINSTRUCTIONS   53  \nDate of issue: June, 2021 Revision: 11 Pg. : 3/56  \n1. IMPORTANT WARNINGS AND ADVICES  \nThis installation and operation manual isan integral part of the equipment and must be kept for future consultation.  \nUnless otherwise stated, this manual is addressed to operators (staff members who uses the equipment on a daily basis) and to servicemen (staff members qualified to carry out the installation and/or maintenance) . The parts of the manual addressed only to servicemen are pointed out accordingly. Please read carefully the warnings listed here below before installation and start-up of the equipment. This equipment has been designed to produce slushes, sorbets and similar products.  \nUpon rece","cbCail2Jay4YMLjs","https://ap.wps.com/l/cbCail2Jay4YMLjs","pdf",1560971,56,"English","# 1. IMPORTANT WARNINGS AND ADVICES\n# 2. EQUIPMENT KIT\n# 3. TRANSPORT TIPS\n# 4. LIFTING TIPS\n# 5. TECHNICAL SPECIFICATIONS\n# 6. POSITIONING\n# 7. CONNECTION TO THE POWER SUPPLY MAINS\n# 8. START-UP PROCEDURES\n# 9. ELECTRONIC CONTROL BOARD\n## Manual mode\n## Automatic mode\n## Setting mode\n# 10. MECHANICAL CONTROL BOARD\n# 11. OPERATING INSTRUCTIONS\n# 12. DAILY CLEANING AND SANITIZING PROCEDURES\n# 13. SPECIAL MAINTENTANCE\n## Condenser cleaning\n## Control and replacement of seals\n## Winter storage\n# 14. DISCLAIMER\n# 15. TROUBLESHOOTING GUIDE\n# 16. WIRING DIAGRAM\n# 17. EXPLODED VIEW\n## I-PRO-2E\n## I-PRO2-E w/ LED PANEL\n## I-PRO2-M w/ TIMER\n## I-PRO2-M w/ LED PANEL\n## I-PRO3-E\n## I-PRO3-E w/ LED PANEL\n## I-PRO3-M w/ TIMER\n## I-PRO3-M w/ LED PANEL\n# 18. PLANNED MAINTAINENCE KIT INSTRUCTIONS","[{\"question\":\"Who is the manual intended for, and what parts apply to servicemen only?\",\"answer\":\"The manual addresses operators for daily equipment use and servicemen qualified for installation and/or maintenance. Sections specifically aimed at servicemen are indicated accordingly.\"},{\"question\":\"What precautions are required during transport before start-up?\",\"answer\":\"Keep the device upright to prevent compressor oil from entering the cooling circuit. If transported in another position, return it to the correct position at least twenty minutes before start-up procedures.\"},{\"question\":\"What does the manual warn about regarding machine use and installation location?\",\"answer\":\"Use must match the designed purpose, and improper use may cause damage. The equipment is not intended for outdoor use, must not be installed where water jets are used, and should be installed where qualified staff can control it.\"}]","GRANITA SLUSH MACHINE IPro OPERATOR’S MANUAL - June 2021 Revision 11 | PDF",1792266124,141]