[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-671592-105":59,"doc-detail-671592-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","gp2d12-optoelectronic-distance-measuring-sensor-analog-output","GP2D12 Optoelectronic Distance Measuring Sensor - Analog Output","","GP2D12 is a distance measuring optoelectronic sensor with integrated signal processing and an analog voltage output. It provides a measuring range of 10 to 80 cm with typical response time of 39 ms and start-up delay of 44 ms. Operating on a 4.5 to 5.5 V supply, it features an output pulse cycle duration of 32 ms and average supply current of 33 mA. Reliability data include environmental testing, shock, and vibration, with quality inspection criteria defined by AQL values.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/gp2d12-optoelectronic-distance-measuring-sensor-analog-output/671592/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/gp2d12-optoelectronic-distance-measuring-sensor-analog-output/671592.png","ImageObject",300,407,{"name":92,"@type":93},"Kyle","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02","2026-11-01",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the GP2D12 measuring distance range and output type?","Question",{"text":112,"@type":113},"The GP2D12 measures distances from 10 to 80 cm. It uses integrated signal processing and provides an analog voltage output (VO).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the typical response time and start-up delay for the GP2D12?",{"text":117,"@type":113},"The typical response time is 39 ms and the typical start-up delay is 44 ms.",{"name":119,"@type":110,"acceptedAnswer":120},"What reliability and inspection methods are specified for the device?",{"text":121,"@type":113},"Reliability requirements include temperature cycling, high/low temperature storage, operational life at high temperature, mechanical shock, and variable frequency vibration. Manufacturer’s inspection uses a single sampling plan, normal inspection level II based on ISO 2859, with AQL values for major and minor defects.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},671592,1793577523,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","GP2D12 Optoelectronic Device  \nFEATURES  \n• Analog output  \n• Effective Range: 10 to 80 cm  \n• LED pulse cycle duration: 32 ms  \n• Typical response time: 39 ms  \n• Typical start up delay: 44 ms  \n• Average current consumption: 33 mA  \n• Detection area diameter @ 80 cm: 6 cm  \nDESCRIPTION  \nThe GP2D12 is a distance measuring sensor with integrated signal processing and analog voltage output.  \n\n|  |  | |\n| --- | --- | --- |\n| | \u003Cbr>1 2 3 |  |\n|  |  |  |\n| PIN SIGNAL NAME 1 VO 2 GND 3 V CC\u003Cbr>GP2D12-8 |  |  |\n\nFigure 1. Pinout  \nGND V CC  \nVO  \nGP2D12-4  \nFigure 2. Block Diagram  \nELECTRICAL SPECIFICATIONS  \nAbsolute Maximum Ratings  \nTa = 25°C, V CC = 5 VDC  \n\n| PARAMETER | SYMBOL | RATING | UNIT |\n| --- | --- | --- | --- |\n| Supply Voltage | V CC | -0.3 to +7.0 | V |\n| Output Terminal Voltage | VO | -0.3 to (V CC+ 0.3) | V |\n| Operating Temperature | Topr | -10 to +60 | °C |\n| Storage Temperature | Tstg | -40 to +70 | °C |\n\nOperating Supply Voltage  \n\n| PARAMETER | SYMBOL | RATING | UNIT |\n| --- | --- | --- | --- |\n| Operating Supply Voltage | V CC | 4.5 to 5.5 | V |\n\nElectro-optical Characteristics  \nTa = 25°C, V CC = 5 VDC  \n\n| PARAMETER | SYMBOL | CONDITIONS | MIN. | TYP. | MAX. | UNIT | NOTES |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| Measuring Distance Range | ΔL |  | 10 | - | 80 | cm | 1, 2 |\n| Output Voltage | VO | L = 80 cm | 0.25 | 0.4 | 0.55 | V | 1, 2 |\n| Output Voltage Difference | ΔVO | Output change at L change (80 cm-10 cm) | 1.75 | 2.0 | 2.25 | V | 1, 2 |\n| Average Supply Current | ICC | L = 80 cm | - | 33 | 50 | mA | 1, 2 |\n\nNOTES:  \n1. Measurements made with Kodak R-27 Gray Card , using the white side,(90% reflectivity) .  \n2. L = Distance to reflective object.  \n\n| V CC (POWER SUPPLY)  \u003Cbr>DISTANCE MEASURMENT OPERATING\u003Cbr>VO\u003Cbr>(OUTPUT)\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>|\n| --- |\n| GP2D12-5 |\n\nFigure 3. Timing Diagram  \nRELIABILITY  \nThe reliability of requirements of this device are listed in Table 1.  \nTable 1. Reliability  \n\n| TEST ITEMS | TEST CONDITIONS | FAILURE\u003Cbr>JUDGEMENT\u003Cbr>CRITERIA | SAMPLES (n),\u003Cbr>DEFECTIVE (C) |\n| --- | --- | --- | --- |\n|  |  |  |  |\n| Temperature Cycling | One cycle-40°C (30 min.) to +70°C in 30 minutes, repeated 25 times | Initial × 0.8 > VOVO > Initial × 1.2 | n = 11, C = 0 |\n| High Temperature and High Humidity Storage | +40°C, 90% RH, 500h |  | n = 11, C = 0 |\n| High Temperature Storage | +70°C, 500h |  | n = 11, C = 0 |\n| Low Temperature Storage | -40°C, 500h |  | n = 11, C = 0 |\n| Operational Life (High Temperature) | +60°C, V CC = 5 V, 500h |  | n = 11, C = 0 |\n| Mechanical Shock | 100 m / s2 , 6.0 ms\u003Cbr>3 times / ±X, ±Y, ±Z direction |  | n = 6, C = 0 |\n| Variable Frequency Vibration | 10-to-55-to-10 Hz in 1 minute Amplitude: 1.5 mm\u003Cbr>2h in each X, Y, Z direction |  | n = 6, C = 0 |\n\nNOTES:  \n1. Test conditions are according to Electro-optical Characteristics, shown on page 2.  \n2. At completion of the test, allow device to remain at nominal room temperature and humidity (non-condensing) for two hours.  \n3. Confidence level: 90%, Lot Tolerance Percent Defect (LTPD): 20% / 40% .  \nMANUFACTURER’S INSPECTION  \nInspection Lot  \nInspection shall be carried out per each delivery lot.  \nInspection Method  \nA single sampling plan, normal inspection level II based on ISO 2859 shall be adopted.  \nTable 2. Quality Level  \n\n| DEFECT | INSPECTION ITEM and TEST METHOD | AQL (%) |\n| --- | --- | --- |\n|  |  |  |\n| Major Defect | Electro-optical characteristics defect | 0.4 |\n| Minor Defect | Defect to appearance or dimensions (crack, split, chip, scratch, stain)* | 1.0 |\n\nNOTE: *Any one of these that affects the Electro-optical Characteristics shall be considered a defect.  \n\n| ANALOG VOLTAGE OUTPUT (V) | 3.0\u003Cbr>2.8\u003Cbr>2.6\u003Cbr>2.4\u003Cbr>2.2\u003Cbr>2.0\u003Cbr>1.8\u003Cbr>1.6\u003Cbr>1.4\u003Cbr>1.2\u003Cbr>1.0\u003Cbr>0.8\u003Cbr>0.6\u003Cbr>0.4\u003Cbr>0.2 | \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>0 10 20 30 40 50 60 70 80 |  |\n| --- | --- | --- | --- |\n| DISTANCE TO REFLECTIVE OBJECT (cm)\u003Cbr>NOTES: |  |  |  |\n|  White paper (Reflectance ratio 90%)  Gray paper ","cbCaib8I2ZzYZyF6","https://ap.wps.com/l/cbCaib8I2ZzYZyF6","pdf",290782,"English","# Features\n# Description\n# Pinout and Block Diagram\n# Electrical Specifications\n## Absolute Maximum Ratings\n## Operating Supply Voltage\n## Electro-optical Characteristics\n# Reliability and Manufacturer’s Inspection\n## Reliability Tests\n## Quality Level (AQL)\n# Output/Distance Characteristics\n# Package Specifications","[{\"question\":\"What is the GP2D12 measuring distance range and output type?\",\"answer\":\"The GP2D12 measures distances from 10 to 80 cm. It uses integrated signal processing and provides an analog voltage output (VO).\"},{\"question\":\"What are the typical response time and start-up delay for the GP2D12?\",\"answer\":\"The typical response time is 39 ms and the typical start-up delay is 44 ms.\"},{\"question\":\"What reliability and inspection methods are specified for the device?\",\"answer\":\"Reliability requirements include temperature cycling, high/low temperature storage, operational life at high temperature, mechanical shock, and variable frequency vibration. Manufacturer’s inspection uses a single sampling plan, normal inspection level II based on ISO 2859, with AQL values for major and minor defects.\"}]","GP2D12 Optoelectronic Distance Measuring Sensor - Analog Output | PDF",25]