[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641071-105":59,"doc-detail-641071-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","goodman-gmec96-service-instructions-two-stage-furnace-with-multi-speed-ecm-motor","Goodman GMEC96 - Service Instructions - Two Stage Furnace with multi-speed ECM Motor","","Service Instructions manual for Goodman Brand GMEC96 and Amana Brand AMEC96 two-stage furnaces equipped with a multi-speed ECM motor. The document targets qualified, professionally trained HVAC technicians only and emphasizes safety responsibilities during installation and service. It outlines critical warnings on property damage, personal injury, and death, including directives to disconnect power before servicing, and special hazard guidance for carbon monoxide risks in enclosed, poorly ventilated areas. It also provides consumer and servicer notices and references an organized table of contents for system topics such as installation, operation, servicing, and maintenance.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/goodman-gmec96-service-instructions-two-stage-furnace-with-multi-speed-ecm-motor/641071/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/goodman-gmec96-service-instructions-two-stage-furnace-with-multi-speed-ecm-motor/641071.png","ImageObject",300,407,{"name":92,"@type":93},"Quinn Holloway","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-06","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is authorized to perform service on the Goodman GMEC96 and Amana AMEC96 furnaces?","Question",{"text":112,"@type":113},"The manual states it must be used by qualified, professionally trained HVAC technicians only. It also specifies that service should be performed by individuals familiar with required safety procedures and equipped with appropriate tools and parts.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the key safety warnings before servicing the unit?",{"text":117,"@type":113},"The manual instructs technicians to recognize safety symbols and to disconnect all power before servicing or installing the unit, noting that multiple power sources may be present. It warns that failing to do so may cause property damage, personal injury, or death.",{"name":119,"@type":110,"acceptedAnswer":120},"What carbon monoxide precautions does the manual provide?",{"text":121,"@type":113},"It warns against operating carbon monoxide producing devices in enclosed areas like garages or utility rooms due to CO poisoning hazards. If installed in an enclosed area, it requires adequate direct outside ventilation and notes that CO emissions can be recirculated and may cause serious illness, permanent brain damage, or death.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641071,1792876113,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},2336474466712,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Service Instructions  \nGoodman® Brand GMEC96  \n& Amana® Brand AMEC96 Two Stage Furnace with multi-speed ECM Motor  \nThis manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. The material in this manual does not supercede manufacturers installation and operation instructions.  \n® is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L. P. , Houston, TX, USA. All rights reserved.  \nRS6612013 August 2014  \nCopyright© 2014 Goodman Company, L. P.  \nTABLE OF CONTENTS  \nIMPORTANT INFORMATION ......................... 2-6  \nPRODUCT IDENTIFICATION ........................ 7-8  \nINSTALLATION CONSIDERATIONS ........... 9-26  \nSYSTEM OPERATION ...............................27-33  \nACCESSORIES .......................................... 34-37  \nSERVICING TABLE OF COnTENTS .................38  \nSERVICING ................................................ 39-56  \nMAINTENANCE ............................................57-58  \nIMPORTANTINFORMATION  \nPride and workmanship go into every product to provide our customers with quality products. It is possible, however, that during its lifetime a product may require service. Products should be serviced only by a qualified service technician who is familiar with the safety procedures required in the repair and who is equipped with the proper tools, parts, testing instruments and the appropriate service manual. REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATE SERVICE MANUAL BEFORE BEGINNING REPAIRS.  \nIMPORTANT NOTICES FOR CONSUMERS AND SERVICERS  \nRECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS  \n|  |\n| --- |\n| TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH, DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE. |\n\nGOODMAN WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES. IF YOU INSTALL OR PERFORM SERVICE ON THIS UNIT, YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICH MAY RESULT. MANY JURISDICTIONS REQUIRE A LICENSE TO INSTALL OR SERVICE HEATING AND AIR CONDITIONING EQUIPMENT.  \n\n| |\n| --- |\n| \u003Cbr>HIGH VOLTAGE\u003Cbr>DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAYBE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.\u003Cbr>|\n\nIMPORTANTINFORMATION  \n\n|  |  |  |  |\n| --- | --- | --- | --- |\n|  | |  DANGER\u003Cbr>\u003Cbr>|  |\n|  | |  |  |\n|  | CARBON MONOXIDE POISONING HAZARD\u003Cbr>Special warning for installation of furnaces or air handling units in enclosed area such as garages, utility rooms or parking areas. Carbon monoxide producing devices (such as automobile, space heater, gas water heater, etc.) Should not be operated in enclosed areas such as unventilated garages or utility rooms because of the danger of carbon monoxide (CO) poisoning resulting from the exhaust emissions. If a furnace or air handler is installed in an enclosed area and a carbon monoxide producing device is operated therein, there must be adequate direct outside ventilation. Carbon monoxide emissions can be (re)circulated throughout the structure if the furnace or air handler is operating in any mode. CO can cause serious illness including permanent brain damage or death. |  |  |\n|  | |  DANGER\u003Cbr>\u003Cbr>|  |\n|  | RISQUE D'EMPOISONNEMENTAU MONOXYDE DE CARBONE\u003Cbr>Avertissement special au sujet de l'installation d'appareils de chauffage ou de traitement d'air dans des endroits clos, tets les garages, les locaux d'entretien et les stationnements. Evitez de mettre en marche les appareils produisant du monoxyde de carbone (tels que les automobile, les appareils de chauffage autonome,etc. ) dans des endroits non ventilés tels que les d'empoisonnement au monoxyde de carb","cbCaimG453VtYBy7","https://ap.wps.com/l/cbCaimG453VtYBy7","pdf",1665521,58,"English","# IMPORTANT INFORMATION\n## IMPORTANT NOTICES FOR CONSUMERS AND SERVICERS\n## RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS\n# TABLE OF CONTENTS\n## PRODUCT IDENTIFICATION\n## INSTALLATION CONSIDERATIONS\n## SYSTEM OPERATION\n## ACCESSORIES\n## SERVICING TABLE OF COnTENTS\n## SERVICING\n## MAINTENANCE","[{\"question\":\"Who is authorized to perform service on the Goodman GMEC96 and Amana AMEC96 furnaces?\",\"answer\":\"The manual states it must be used by qualified, professionally trained HVAC technicians only. It also specifies that service should be performed by individuals familiar with required safety procedures and equipped with appropriate tools and parts.\"},{\"question\":\"What are the key safety warnings before servicing the unit?\",\"answer\":\"The manual instructs technicians to recognize safety symbols and to disconnect all power before servicing or installing the unit, noting that multiple power sources may be present. It warns that failing to do so may cause property damage, personal injury, or death.\"},{\"question\":\"What carbon monoxide precautions does the manual provide?\",\"answer\":\"It warns against operating carbon monoxide producing devices in enclosed areas like garages or utility rooms due to CO poisoning hazards. If installed in an enclosed area, it requires adequate direct outside ventilation and notes that CO emissions can be recirculated and may cause serious illness, permanent brain damage, or death.\"}]","Goodman GMEC96 - Service Instructions - Two Stage Furnace with multi-speed ECM Motor | PDF",1792712651,146]