[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641074-105":59,"doc-detail-641074-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","gmss92-gcss92-single-stage-multi-speed-gas-furnace-up-to-92-afue-product-specifications","GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace up to 92% AFUE - Product Specifications","","Single-stage, multi-speed gas furnace product specifications for GMSS92 and GCSS92 models rated up to 92% AFUE. Technical features include heavy-duty aluminized-steel and stainless-steel secondary heat exchangers, a silicon nitride igniter, and self-diagnostic control with multi-speed blower options. Cabinet installation configurations cover upflow, downflow, and horizontal left/right positions, with options for direct (2-pipe) or non-direct (1-pipe) venting. Specifications list heating inputs/outputs, AFUE, temperature rise ranges, vent diameters, burner counts, blower electrical data, filtration, and key installation/service notes.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/gmss92-gcss92-single-stage-multi-speed-gas-furnace-up-to-92-afue-product-specifications/641074/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/gmss92-gcss92-single-stage-multi-speed-gas-furnace-up-to-92-afue-product-specifications/641074.png","ImageObject",300,407,{"name":92,"@type":93},"\tJames","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the key heat exchanger and control features in GMSS92/GCSS92?","Question",{"text":112,"@type":113},"The units use a heavy-duty aluminized-steel tubular heat exchanger and a stainless-steel secondary heat exchanger. They also include a single-stage gas valve, silicon nitride igniter, and a self-diagnostic control board with color-coded low-voltage terminals.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What venting options are supported and how are they configured?",{"text":117,"@type":113},"The cabinets are certified for direct vent (2-pipe) or non-direct vent (1-pipe). Top venting is easy to install, with optional side venting, and installer-supplied combustion air and flue outlet piping must meet diameter requirements.",{"name":119,"@type":110,"acceptedAnswer":120},"What cautions and clearance requirements apply for performance and servicing?",{"text":121,"@type":113},"For bottom return, failure to unfold flanges may reduce airflow by up to 18%, affecting performance and noise. Servicing or cleaning requires a 24-inch front clearance, and unit accessibility clearance must take precedence over enclosure clearances when greater.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641074,1793006660,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":41},2336474466412,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","HeatinG input: 40,000–120,000 Btu/H  \nGMSS92 / GCSS92  \nSinGle-StaGe  \nMulti-Speed GaS FurnaCe up to 92% aFue  \nStandard Features  \n• Heavy-duty aluminized-steel tubular heat exchanger  \n• Stainless-steel secondary heat exchanger  \n• Single-stage gas valve  \n• Durable Silicon Nitride igniter  \n• Multi-speed blower motor  \n• Quiet single-speed induced draft blower  \n• Self-diagnostic control board  \n• Color-coded low-voltage terminals  \n• All models comply with California Low NOx emissions standards  \nCabinet Features  \n• Designed for multi-position installation—GMSS92: upflow, horizontal left or right GCSS92: downflow, horizontal left or right  \n• Certified for direct vent (2-pipe) or non-direct vent (1-pipe)  \n• Easy-to-install top venting with optional side venting  \n• Convenient left or right connection for gas and electrical service  \n• Cabinet air leakage (QLeak) ≤ 2%  \n• Heavy-gauge steel cabinet with durable finish  \n• Foil-faced insulated heat exchanger cabinet  \n• Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications  \nContents  \nNomenclature ...........................................2  \nProduct Specifications ..............................3  \nDimensions ............................................... 5  \nAirflow Specifications................................ 7  \nWiring Diagram.......................................10  \nAccessories .............................................. 11  \n* Complete warranty details available from your local dealer or at [www.goodmanmfg.com. To](www.goodmanmfg.com. To) receive the Lifetime Heat Exchanger Limited Warranty  \n(good for as long as you own your home), and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.  \nProduct SPecificationS  \nnoMenClature  \nG M S S 92 040 3 B N A A  \n1   2   3   4   5,6 7,8,9  10   11   12   13   14   \n Brand            Minor Revision   \nG -­‐ Goodman          A -­‐ Initial Release  \n         B -­‐ 1st Revision  \n Configuration           \nM -­‐ Upflow/Horizontal         Major Revision   \nC -­‐ Downflow/Horizontal        A -­‐ Initial Release  \n       B -­‐ 1st Revision  \n Motor         \nV -­‐ Variable Speed ECM / ComfortNet       NOx   \nE -­‐ Multi-­‐Speed ECM      N -­‐ Low NOx  \nS -­‐ Single Speed       \n     Cabinet Width   \n Gas Valve     B -­‐ 17.5\"  \nM -­‐ Modulating    C -­‐ 21\"  \nC -­‐ 2 Stage    D -­‐ 24.5\"  \nS -­‐ Single Stage     \nAFUE    Maximum CFM   \n92 -­‐ 92% AFUE  2 -­‐ 800 CFM  \n96 -­‐ 96% AFUE  3 -­‐ 1200 CFM  \n97 -­‐ 97% AFUE  4 -­‐ 1600 CFM  \n 5 -­‐ 2000 CFM  \nMBTU/h   \n040 -­‐ 40,000 BTU/h  \n060 -­‐ 60,000 BTU/h  \n120 -­‐ 120,000 BTU/h  \nSpeCiFiCationS-GMSS92  \n\n|  | GMSS92\u003Cbr>0402BNA | GMSS92\u003Cbr>0603BNA | GMSS92\u003Cbr>0803BNA | GMSS92\u003Cbr>0804CNA | GMSS92\u003Cbr>0805CNA | GMSS92\u003Cbr>1004CNA | GMSS92\u003Cbr>1005CNA | GMSS92\u003Cbr>1205DNA |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Heating Data\u003Cbr>High Fire Input¹ | 40,000 | 60,000 | 80,000 | 80,000 | 80,000 | 100,000 | 100,000 | 120,000 |\n| High Fire Output¹ | 36,840 | 55,260 | 73,680 | 73,680 | 73,680 | 92,100 | 92,100 | 110,520 |\n| AFUE² | 92 | 92 | 92 | 92 | 92 | 92 | 92 | 92 |\n| Temperature Rise Range (°F) | 30-60 | 35-65 | 35-65 | 35-65 | 25-55 | 35-65 | 35-65 | 35-65 |\n| Vent Diameter³ | 2\" -3\" | 2\" -3\" | 2\" -3\" | 2\" -3\" | 2\" -3\" | 2\" -3\" | 2\" -3\" | 3\" |\n| No. of Burners | 2 | 3 | 4 | 4 | 4 | 5 | 5 | 6 |\n| Circulator Blower |  |  |  |  |  |  |  |  |\n| Available AC @ 0.5\" ESP | 1.5-3 | 1.5-3 | 1.5-3 | 3-5 | 3-5 | 3-5 | 3-5 | 3-5 |\n| Size (D x W) | 10\" x 8\" | 10\" x 8\" | 10\" x 8\" | 10\" x 10\" | 11\" x 10\" | 10\" x 10\" | 11\" x 10\" | 11\" x 11\" |\n| Horsepower @ 1075 RPM | ⅓ | ⅓ | ⅓ | ½ | ¾ | ½ | ¾ | ¾ |\n| Speed | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |\n| Filter Size (in²) |  |  |  |  |  |  |  |  |\n| Permanent | 363 | 491 | 654 | 654 | 818 | 818 | 818 | 981 |\n| Disposable | 182 | 245 | 327 | 327 | 409 | 409 | 409 | 491 |\n| Elect","cbCaipJwVWvHq3eJ","https://ap.wps.com/l/cbCaipJwVWvHq3eJ","pdf",752559,12,"English","# Product Specifications\n## Nomenclature\n## Cabinet Features\n## Heating Data & Technical Specifications\n## Notes & Installation Requirements\n## Shipping Weight & Electrical Data","[{\"question\":\"What are the key heat exchanger and control features in GMSS92/GCSS92?\",\"answer\":\"The units use a heavy-duty aluminized-steel tubular heat exchanger and a stainless-steel secondary heat exchanger. They also include a single-stage gas valve, silicon nitride igniter, and a self-diagnostic control board with color-coded low-voltage terminals.\"},{\"question\":\"What venting options are supported and how are they configured?\",\"answer\":\"The cabinets are certified for direct vent (2-pipe) or non-direct vent (1-pipe). Top venting is easy to install, with optional side venting, and installer-supplied combustion air and flue outlet piping must meet diameter requirements.\"},{\"question\":\"What cautions and clearance requirements apply for performance and servicing?\",\"answer\":\"For bottom return, failure to unfold flanges may reduce airflow by up to 18%, affecting performance and noise. Servicing or cleaning requires a 24-inch front clearance, and unit accessibility clearance must take precedence over enclosure clearances when greater.\"}]","GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace up to 92% AFUE - Product Specifications | PDF",1792712659]