[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-641612-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-641612-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","gmh95gch95gme95gch9-gas-fired-warm-air-furnace-installation-instructions","GMH95/GCH95/GME95/GCH9 - Gas-Fired Warm Air Furnace Installation Instructions","","Installation instructions for GAS-FIRED WARM AIR FURNACE models GMH95/GCH95/GME95/GCH9. Provide guidance for professional installers, including safety precautions, component identification, product application, location requirements, and combustion and ventilation air requirements. Cover installation positions, horizontal application considerations such as drain trap and lines, leveling, alternate vent/flue and combustion air connections, electrical and gas line connections, drain pan, freeze protection, and special provisions for propane gas/high altitude as well as vent/flue and combustion air piping.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/gmh95gch95gme95gch9-gas-fired-warm-air-furnace-installation-instructions/641612/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/gmh95gch95gme95gch9-gas-fired-warm-air-furnace-installation-instructions/641612.png","ImageObject",300,407,{"name":42,"@type":43},"Aditya","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-27","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What safety precautions must installers follow before installing or servicing the furnace?","Question",{"text":62,"@type":63},"Installers are instructed to thoroughly read and follow the instruction manual and pay special attention to safety warnings. Safety precautions are intended to supplement existing practices, and the manual’s precautions take precedence when there is a direct conflict.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What documentation should be kept adjacent to the unit after installation?",{"text":67,"@type":63},"The installer is instructed to affix all manuals adjacent to the unit so relevant information is available at the point of use.",{"name":69,"@type":60,"acceptedAnswer":70},"Which topics are covered under horizontal applications and considerations?",{"text":71,"@type":63},"The manual includes drain trap and lines, leveling, alternate vent/flue and combustion air connections, alternate electrical and gas line connections, drain pan, freeze protection, and furnace suspension.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},641612,1792722465,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145},962085564549,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","GMH95/GCH95/GME95/GCH9  \nGAS-FIRED WARM AIR FURNACE INSTALLATION INSTRUCTIONS  \nInstaller: Affix all manuals adjacent to the unit.  \n(Type FSP CATEGORY IV Direct or Non Direct Vent Air Furnace)  \nThese furnaces comply with requirements embodied in the American National Standard / National Standard of Canada ANSIZ21 .47·CSA-2 .3 Gas Fired Central Furnaces .  \nRECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.  \n\n| ATTENTION INSTALLING PERSONNEL |  |\n| --- | --- |\n|  |  |\n| As a professional installer you have an obligation to know the product better than the customer. This includes all safety\u003Cbr>precautions and related items.\u003Cbr>Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous than\u003Cbr>when the unit is in operation.\u003Cbr>Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer\u003Cbr>in its safe use.\u003Cbr>Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good safety\u003Cbr>practices...follow them.\u003Cbr>The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence. |  |\n|  |  |\n\nIO-299P 10/2012  \nNOTE: Please contact your distributor or our website for the applicable Specification Sheet referred to in this manual.  \nGoodman Manufacturing Company, L. P. 5151 San Felipe, Suite 500, Houston, TX 77056 [www.goodmanmfg.com](www.goodmanmfg.com)[ ](www.goodmanmfg.com)© 2006-2012 Goodman Manufacturing Company, L. P.  \nTable of Contents  \nIMPORTANT NOTE TO THE OWNER REGARDING PRODUCT WARRANTY ............................................................................................ 4  \nI. Component Identification ............................................................................................................................................... 5  \nII. Safety .............................................................................................................................................................................. 6  \nELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS .................................................................................................................... 6  \nIII. Product Application ...................................................................................................................................................... 6  \nIV. Location Requirements & Considerations ................................................................................................................. 7  \nGENERAL ......................................................................................................................................................................... 7  \nCLEARANCES AND ACCESSIBILITY .......................................................................................................................................... 8  \nFURNACE SUSPENSION ....................................................................................................................................................... 8  \nEXISTING FURNACE REMOVAL ............................................................................................................................................... 8  \nTHERMOSTAT LOCATION ........................................................................................................................................................ 9  \nV. Combustion & Ventilation Air Requirements ............................................................................................................... 9  \nVI. Installation Positions .........................................................................","cbCaigzcL5cD19MG","https://ap.wps.com/l/cbCaigzcL5cD19MG","pdf",1641937,52,"English","# IMPORTANT NOTE TO THE OWNER REGARDING PRODUCT WARRANTY\n# I. Component Identification\n# II. Safety\n## ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS\n# III. Product Application\n# IV. Location Requirements & Considerations\n## GENERAL\n## CLEARANCES AND ACCESSIBILITY\n## FURNACE SUSPENSION\n## EXISTING FURNACE REMOVAL\n## THERMOSTAT LOCATION\n# V. Combustion & Ventilation Air Requirements\n# VI. Installation Positions\n# VII. Horizontal Applications & Considerations\n## GENERAL\n## DRAIN TRAP AND LINES\n## LEVELING\n## ALTERNATE VENT/FLUE AND COMBUSTION AIR CONNECTIONS\n## ALTERNATE ELECTRICAL AND GAS LINE CONNECTIONS\n## DRAIN PAN\n## FREEZE PROTECTION\n## FURNACE SUSPENSION\n# VIII. Propane Gas /High Altitude Installations\n# IX. Vent/Flue Pipe & Combustion Air Pipe\n## GENERAL","[{\"question\":\"What safety precautions must installers follow before installing or servicing the furnace?\",\"answer\":\"Installers are instructed to thoroughly read and follow the instruction manual and pay special attention to safety warnings. Safety precautions are intended to supplement existing practices, and the manual’s precautions take precedence when there is a direct conflict.\"},{\"question\":\"What documentation should be kept adjacent to the unit after installation?\",\"answer\":\"The installer is instructed to affix all manuals adjacent to the unit so relevant information is available at the point of use.\"},{\"question\":\"Which topics are covered under horizontal applications and considerations?\",\"answer\":\"The manual includes drain trap and lines, leveling, alternate vent/flue and combustion air connections, alternate electrical and gas line connections, drain pan, freeze protection, and furnace suspension.\"}]","GMH95/GCH95/GME95/GCH9 - Gas-Fired Warm Air Furnace Installation Instructions | PDF",1792715450,131]