[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641079-105":59,"doc-detail-641079-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","gmec96-two-stage-multi-speed-ecm-gas-furnace-product-specifications","GMEC96 - Two-Stage, Multi-Speed ECM Gas Furnace - Product Specifications","","GMEC96 is a two-stage, multi-speed ECM gas furnace product specification covering heating input ranges from 30,000 to 120,000 BTU/h and up to 96% AFUE efficiency. The document outlines nomenclature, product specifications, dimensions, airflow requirements, wiring diagrams, and accessories. It details standard features such as an energy-efficient ECM blower, stainless-steel secondary heat exchanger, silicon nitride igniter, self-diagnostic control board, low-voltage terminal provisions, and quiet multi-speed operation. It also includes model-specific heating data, circulator blower and filter sizing, electrical ratings, vent diameter guidance, and shipping weights, plus California NOx compliance and warranty registration terms.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/gmec96-two-stage-multi-speed-ecm-gas-furnace-product-specifications/641079/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/gmec96-two-stage-multi-speed-ecm-gas-furnace-product-specifications/641079.png","ImageObject",300,407,{"name":92,"@type":93},"Kyle","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What heating input range and efficiency does the GMEC96 specification cover?","Question",{"text":112,"@type":113},"The GMEC96 is listed with heating inputs from 30,000–120,000 BTU/h and efficiency up to 96% AFUE.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which standard components and controls are included in the GMEC96 furnace?",{"text":117,"@type":113},"It uses a multi-speed ECM blower motor, heavy-duty heat exchanger construction, a silicon nitride igniter, a two-stage gas valve, and a self-diagnostic control board with fault code history.",{"name":119,"@type":110,"acceptedAnswer":120},"What vent diameter guidance and airflow/electrical considerations are provided?",{"text":121,"@type":113},"Vent diameter is specified as 2\"–3\" depending on furnace input and installation, with notes that PVC combustion air and flue outlet piping must be supplied as required. Electrical data includes minimum circuit ampacity, max overcurrent protection, and installer wire sizing guidance.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641079,1792865304,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":46,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":31},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","GMEC96  \nHeating Input: 30,000–120,000 BTU/h  \nTwo-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE  \nContents  \nNomenclature........................................ 2  \nProduct Specifications ........................... 3  \nDimensions ............................................ 4  \nAirflow Specifications ............................ 5  \nWiring Diagrams .................................. 16  \nAccessories .......................................... 20  \nStandard Features  \n• Energy-efficient, multi-speed ECM blower motor  \n• Heavy-duty, aluminized-steel tubular heat exchanger  \n• Stainless-steel secondary heat exchanger  \n• Two-stage gas valve provides quiet, economical heating  \n• Durable Silicon Nitride igniter  \n• Quiet two-speed induced draft blower  \n• Self-diagnostic control board with constant memory fault code history output to a LED  \n• Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier  \n• Low continuous fan speed options offer quiet air circulation  \n• All models comply with California 40 ng/J Low NOx emissions standard  \n• For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the SCAQMD Clean Air Furnace Rebate [Program: www.CleanAirFurnaceRebate.com](Program: www.CleanAirFurnaceRebate.com).  \n• AHRI Certified; ETL Listed  \nCabinet Features  \n• Designed for multi-position installation—upflow, horizontal left or right  \n• Certified for direct vent (2-pipe) or non-direct vent (1-pipe)  \n• Easy-to-install top venting with optional side venting  \n• Convenient left or right connection for gas and electrical service  \n• Cabinet air leakage (QLeak) ≤ 2%  \n• Heavy-gauge steel cabinet with durable finish  \n• Fully insulated heat exchanger and blower section  \n• Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications  \n* [Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty](Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty) (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.  \n| G M E C 96 060 3 B N ** |  |\n| --- | --- |\n| | |\n\n\n|  | GMEC96\u003Cbr>0303ANA | GMEC96\u003Cbr>0403ANA | GMEC96\u003Cbr>0603ANA | GMEC96\u003Cbr>0302BNA | GMEC96\u003Cbr>0402BNA | GMEC96\u003Cbr>0603BNB | GMEC96\u003Cbr>0803BNA | GMEC96\u003Cbr>0804CNA | GMEC96\u003Cbr>1004CNA | GMEC96\u003Cbr>1005CNA | GMEC96\u003Cbr>1205DNA |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Heating Data\u003Cbr>High Fire Input¹\u003Cbr>High Fire Output¹ Low-Fire Input¹\u003Cbr>Low-Fire Output¹ AFUE²\u003Cbr>Temp. Rise Range (°F) Vent Diameter³\u003Cbr>No. of Burners | 30,000\u003Cbr>28,800\u003Cbr>21,000\u003Cbr>20,160\u003Cbr>96\u003Cbr>20-50\u003Cbr>2\" -3\"\u003Cbr>2 | 40,000\u003Cbr>38,400\u003Cbr>28,000\u003Cbr>26,880\u003Cbr>96\u003Cbr>20-50\u003Cbr>2\" -3\"\u003Cbr>2 | 60,000\u003Cbr>57,600\u003Cbr>42,000\u003Cbr>40,320\u003Cbr>96\u003Cbr>30-60\u003Cbr>2\" -3\"\u003Cbr>3 | 30,000\u003Cbr>28,800\u003Cbr>21,000\u003Cbr>20,160\u003Cbr>96\u003Cbr>20-50\u003Cbr>2\" -3\"\u003Cbr>2 | 40,000\u003Cbr>38,400\u003Cbr>28,000\u003Cbr>26,880\u003Cbr>96\u003Cbr>20-50\u003Cbr>2\" -3\"\u003Cbr>2 | 60,000\u003Cbr>57,600\u003Cbr>42,000\u003Cbr>40,320\u003Cbr>96\u003Cbr>35-65\u003Cbr>2\" -3\"\u003Cbr>3 | 80,000\u003Cbr>76,800\u003Cbr>56,000\u003Cbr>53,760\u003Cbr>96\u003Cbr>35-65\u003Cbr>2\" -3\"\u003Cbr>4 | 80,000\u003Cbr>76,800\u003Cbr>56,000\u003Cbr>53,760\u003Cbr>96\u003Cbr>25-55\u003Cbr>2\" -3\"\u003Cbr>4 | 100,000\u003Cbr>96,000\u003Cbr>70,000\u003Cbr>67,200\u003Cbr>96\u003Cbr>35-65\u003Cbr>2\" -3\"\u003Cbr>5 | 100,000\u003Cbr>96,000\u003Cbr>70,000\u003Cbr>67,200\u003Cbr>96\u003Cbr>35-65\u003Cbr>2\" -3\"\u003Cbr>5 | 120,000\u003Cbr>115,200\u003Cbr>84,000\u003Cbr>80,640\u003Cbr>96\u003Cbr>35-65\u003Cbr>2\" -3\"\u003Cbr>6 |\n| Circulator Blower\u003Cbr>Available AC @ 0.5\" ESP Size (D x W) Horsepower @ 1075 RPM Speed | 1.5-2\u003Cbr>11\" x 6\"\u003Cbr>1/2\u003Cbr>5 | 1.5-3\u003Cbr>11” x 6","cbCaipKJ6LPTMdD8","https://ap.wps.com/l/cbCaipKJ6LPTMdD8","pdf",1202364,"English","# Nomenclature\n# Product Specifications\n# Dimensions\n# Airflow Specifications\n# Wiring Diagrams\n# Accessories\n## Standard Features\n## Cabinet Features\n## Heating Data\n## Circulator Blower\n## Filter Size\n## Electrical Data\n## Shipping Weight\n## Notes","[{\"question\":\"What heating input range and efficiency does the GMEC96 specification cover?\",\"answer\":\"The GMEC96 is listed with heating inputs from 30,000–120,000 BTU/h and efficiency up to 96% AFUE.\"},{\"question\":\"Which standard components and controls are included in the GMEC96 furnace?\",\"answer\":\"It uses a multi-speed ECM blower motor, heavy-duty heat exchanger construction, a silicon nitride igniter, a two-stage gas valve, and a self-diagnostic control board with fault code history.\"},{\"question\":\"What vent diameter guidance and airflow/electrical considerations are provided?\",\"answer\":\"Vent diameter is specified as 2\\\"–3\\\" depending on furnace input and installation, with notes that PVC combustion air and flue outlet piping must be supplied as required. Electrical data includes minimum circuit ampacity, max overcurrent protection, and installer wire sizing guidance.\"}]","GMEC96 - Two-Stage, Multi-Speed ECM Gas Furnace - Product Specifications | PDF",1792712673]