[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-760921-105":59,"doc-detail-760921-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","generac-generator-sizing-guide","Generac-Generator-Sizing-Guide","","Proper generator sizing guidelines for estimators and installers covering residential and commercial backup power system planning. Includes electrical load assessment using appliance nameplate starting and running requirements, selecting generator output with adequate headroom (about 25% over peak load) and operating margin (around 80% capacity). Provides safety and compliance direction, including installation by qualified dealers or electricians, OSHA and local code adherence, and checks for placement, wiring, gas piping, fuel storage, sound, and exhaust emissions. Includes surge capability and estimating sheets.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/generac-generator-sizing-guide/760921/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/generac-generator-sizing-guide/760921.png","ImageObject",300,407,{"name":92,"@type":93},"Eliana","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-29",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What documents should be used alongside this sizing guide?","Question",{"text":111,"@type":112},"Use the Owner’s Manual, Installation Manual, and other technical documents shipped with each product, and read all accompanying documentation before installing generator-related equipment.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"How should generator output be selected for peak electrical load?",{"text":116,"@type":112},"Choose a generator rating approximately 25% higher than the peak load, so the unit runs comfortably around 80% of full capacity and retains flexibility if the load increases.",{"name":118,"@type":109,"acceptedAnswer":119},"What safety and compliance requirements are emphasized?",{"text":120,"@type":112},"Install, service, and repair the system through a Generac Authorized Service Dealer or a qualified electrician/technician, and follow OSHA requirements and all applicable local, state, and national codes.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},760921,1795944537,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143,"preview_page_count":19,"preview_urls":144},4398048949847,"https://ap-avatar.wpscdn.com/avatar/400002536579ef2da7f?_k=1778318612642679267","iMPortaNt NotiCe:  \nThis booklet is designed to familiarize estimators and installers with proper sizing guidelines for residential and commercial generators. The information is not comprehensive, nor does it replace or supercede any material contained in any of the written documents shipped with the equipment. This booklet should only be used in conjunction with the Owner’s Manual, Installation Manual and other technical documents shipped with each product. Always read all accompanying documentation carefully before attempting to install any generator, transfer switch or related equipment.  \nHoW to use tHis BooKLet:  \nWithin this booklet, you will find electrical load information, plus an outline of generator surge capability, fuel pipe sizing, liquid propane tank sizing, and UPS / generator compatibility. The final pages are perforated for easy removal and can be photocopied to create additional Onsite Estimating Sheets for use with individual jobs.  \nsaFetY iNForMatioN:  \nProper sizing of the generator is crucial to the success of any installation and requires a good working knowledge of electricity and its characteristics, as well as the varying requirements of the electrical equipment comprising the load. When analyzing the electrical load, consult the manufacturer’s nameplate on each major appliance or piece of equipment to determine its starting and running requirements in terms of watts, amps and voltage. When choosing the generator output for commercial or industrial applications, select a rating that is approximately 25% higher than the peak load (for example, if the load is about 40 kilowatts, select a 50 kW genset) . A higher rated generator will operate comfortably at approximately 80% of its full capacity and will provide a margin of flexibility if the load increases in the future.  \nFor safety reasons, Generac recommends that the backup power system be installed, serviced and repaired by a Generac Authorized Service Dealer or a competent, qualified electrician or installation technician who is familiar with applicable codes, standards and regulations.  \nIt is essential to comply with all regulations established by the Occupational Safety & Health Administration (OSHA) and strict adherence to all local, state and national codes is mandatory. Before selecting a generator, check for municipal ordinances that may dictate requirements regarding placement of the unit (setback from building and/or lot line), electrical wiring, gas piping, fuel storage (for liquid propane or diesel tanks), sound and exhaust emissions.  \nIf you have a technical question regarding sizing or installation, contact Generac’s Technical Service Center toll free at 888-GENERAC during normal business hours (8 a. m. to 5 p. m. CST) .  \n􀀱  \nGeNerator  \nsiziNG  \nGuide  \ntaBLe 1  Motor Load reFereNCe  \naC & Heat Pumps  \n\n| description | Hp | running Load\u003Cbr>running amps at amps at amps at\u003Cbr>kW 240V 1ø 208V 3ø 480V 3ø | starting Load\u003Cbr>starting Lramps Lramps Lramps kW at 240V 1ø at 208V 3ø at 480V 3ø |\n| --- | --- | --- | --- |\n| 􀀱 Ton (􀀱2,000 BTU) | 􀀱 | 􀀱 5 􀀳 􀀱 | 􀀳 25 􀀱7 7 |\n| 2 Ton (24,000 BTU) | 2 | 2 􀀱0 7 􀀳 | 6 50 􀀳􀀳 􀀱4 |\n| 􀀳 Ton (􀀳6,000 BTU) | 􀀳 | 􀀳 􀀱5 􀀱0 4 | 9 75 50 22 |\n| 4 Ton (48,000 BTU) | 4 | 4 20 􀀱􀀳 6 | 􀀱2 􀀱00 67 29 |\n| 5 Ton (60,000 BTU) | 5 | 5 25 􀀱6 7 | 􀀱5 􀀱25 8􀀳 􀀳6 |\n| 7.5 Ton (85,000 BTU) | 7.5 | 7.5 􀀳7 24 􀀱􀀱 | 􀀱7 􀀱88 􀀱25 54 |\n| 􀀱0 Ton (􀀱20,000 BTU) | 5 Hp (x2) | 􀀱0 49 􀀳􀀳 􀀱4 | 􀀱5 􀀱25 8􀀳 􀀳6 |\n| 􀀱0 Ton (􀀱20,000 BTU) | 􀀱0 Hp | 􀀱0 49 􀀳􀀳 􀀱4 | 20 250 􀀱67 72 |\n| 􀀱5 Ton (􀀱80,000 BTU) | 7.5 Hp (x2) | 􀀱5 74 49 2􀀱 | 􀀱7 􀀱88 􀀱25 54 |\n| 􀀱5 Ton (􀀱80,000 BTU) | 􀀱5 Hp | 􀀱5 74 49 2􀀱 | 􀀳0 􀀳75 250 􀀱08 |\n| 20 Ton (240,000 BTU) | 􀀱0 Hp (x2) | 20 98 65 28 | 20 250 􀀱67 72 |\n| 20 Ton (240,000 BTU) | 20 Hp | 20 n/a 65 28 | 40 500 􀀳􀀳􀀳 􀀱44 |\n| 25 Ton (􀀳00,000 BTU) | 25 | 25 n/a 82 􀀳5 | 50 625 4􀀱6 􀀱80 |\n| 􀀳0 Ton (􀀳60,000 BTU) | 􀀱5 Hp (x2) | 􀀳0 n/a 98 42 | 􀀳0 􀀳75 250 􀀱08 |\n| 􀀳0 Ton (􀀳60,000 BTU) | 􀀳0 Hp | 􀀳0 n/a 98 42 | 60 750 500 2􀀱7 |\n| 40 Ton (480,000 BTU) |","cbCaidrBTEJU1kFK","https://ap.wps.com/l/cbCaidrBTEJU1kFK","pdf",404590,11,"English","# Important Notice\n# How to Use This Booklet\n# Safety Information\n# Table 1 Motor Load Reference\n## AC and Heat Pumps\n# Table 2 Non-Motor Load Reference\n# Table 3 Surge Capability","[{\"question\":\"What documents should be used alongside this sizing guide?\",\"answer\":\"Use the Owner’s Manual, Installation Manual, and other technical documents shipped with each product, and read all accompanying documentation before installing generator-related equipment.\"},{\"question\":\"How should generator output be selected for peak electrical load?\",\"answer\":\"Choose a generator rating approximately 25% higher than the peak load, so the unit runs comfortably around 80% of full capacity and retains flexibility if the load increases.\"},{\"question\":\"What safety and compliance requirements are emphasized?\",\"answer\":\"Install, service, and repair the system through a Generac Authorized Service Dealer or a qualified electrician/technician, and follow OSHA requirements and all applicable local, state, and national codes.\"}]","Generac-Generator-Sizing-Guide | PDF",28,[145,149,153,157],{"page_no":8,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-29/bc4317bb9d525e25afd8a6649824405c.webp",983,1272,{"page_no":14,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-29/05c6af4075b8510af16b23429bc1c0b1.webp",982,1270,{"page_no":81,"url":154,"width":155,"height":156},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-29/2e1756377dfd426f0728368668397720.webp",981,1269,{"page_no":19,"url":158,"width":159,"height":160},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-29/136cff2509ea4ec986310a8dfb009e22.webp",980,1268]