[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646243-105":59,"doc-detail-646243-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","ge-healthcare-revolution-rt-final-study-mandatory-component","GE HealthCare Revolution RT - Final Study - Mandatory Component","","GE HealthCare Revolution RT final study document consolidating installation deliverables, safety and compliance notices, and customer/site responsibilities. It defines that the GE HealthCare Pre Installation manual is a mandatory component and must be referenced to avoid incomplete site design and preparation. The document specifies general responsibilities, conditions for use of final drawings, dimensional assumptions, and radio-protection determination by a qualified radiological physicist. It also outlines structural engineer responsibilities and requirements for site readiness.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ge-healthcare-revolution-rt-final-study-mandatory-component/646243/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ge-healthcare-revolution-rt-final-study-mandatory-component/646243.png","ImageObject",300,407,{"name":92,"@type":93},"RizkyPratama_92","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-09","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Which manual is mandatory for using this drawing set?","Question",{"text":112,"@type":113},"The document states that a mandatory component of the drawing set is the GE HealthCare Pre Installation manual. Failure to reference it may result in incomplete documentation required for site design and preparation.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What responsibility does GE HealthCare disclaim regarding damages and drawing changes?",{"text":117,"@type":113},"GE HealthCare does not take responsibility for damages resulting from changes made by others, errors from not referring to the complete set, or damage from partial use of final issue drawings. It also rejects responsibility for defective work due to scaling from these drawings.",{"name":119,"@type":110,"acceptedAnswer":120},"Who must determine suitable radio-protection?",{"text":121,"@type":113},"Suitable radiological protection must be determined by a qualified radiological physicist in conformation with local regulations, and GE does not take responsibility for the specification or provision of radio-protection.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646243,1792833706,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},962094243231,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","|  |  |  | |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  | ----\u003Cbr>----\u003Cbr>---- |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n| REV | DATE | MODIFICATIONS |  |  |  |  |  |  |  |  |  |\n| 01-C1-Cover Sheet\u003Cbr>02-C2-Disclaimer-Site Readiness Checklist\u003Cbr>03-A1-General Notes\u003Cbr>04-A2-Equipment Layout\u003Cbr>05-A3-Radiation Protection\u003Cbr>06-A4-Radiation Protection Details\u003Cbr>07-A5-Equipment Dimensions (1)\u003Cbr>08-A6-Equipment Dimensions (2)\u003Cbr>09-A6-Delivery |  |  |  | 10-S1-Structural Notes\u003Cbr>11-S2-Structural Layout\u003Cbr>12-S3-Structural Details (1)\u003Cbr>13-M1-HVAC\u003Cbr>14-E1-Electrical Notes\u003Cbr>15-E2-Electrical Layout\u003Cbr>16-E3-Electrical Elevations\u003Cbr>17-E4-Power Requirements\u003Cbr>18-E5-Electrical Details-Interconnect | ----\u003Cbr>----\u003Cbr>---- |  |  |  |  |  |  |\n|  |  |  |  |  | REVOLUTION RT\u003Cbr>FINAL STUDY |  |  |  |  |  |  |\n|  |  |  |  |  | Drawn by |  | Verified by | Concession | GON/Quote |  | PIM Manual Rev |\n| A mandatory component of this drawing set is the GE HealthCare Pre Installation manual. Failure to reference the Pre Installation manual will result in\u003Cbr>incomplete documentation required for site design and preparation.\u003Cbr>Pre Installation documents for GE HealthCare products can be accessed on the web at: [https://www.gehealthcare.com/support/manuals](https://www.gehealthcare.com/support/manuals) |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  | RET |  | RET | - | ---- |  | 5938483-1EN 2 |\n| GE HealthCare does not take responsibility for any damages resulting from changes on drawings made by others. Errors may occur by not referring to the complete set of final issue drawings. GE HealthCare cannot accept responsibility for any damage due to the partial use of GE HealthCare final issue drawings, however caused. All dimensions are in millimeters unless otherwise specified. Do not scale from printed pdf files. GE HealthCare accepts no\u003Cbr>responsibility or liability for defective work due to scaling from these drawings. |  |  |  |  | Format | Scale | File Name |  |  |  | Date Sheet |\n|  |  |  |  |  | A3 | 1/4\"=1'-0\" | EN-CT-TYP-REVOLUTION_RT-HCT-NF.DWG |  |  |  | 21/JAN/2025 01/18 |\n\n| DISCLAIMER\u003Cbr>GENERAL SPECIFICATIONS\u003Cbr>· GE is not responsible for the installation of developers and associated equipment, lighting, cassette trays and protective screens or derivatives not mentioned in the order.\u003Cbr>· The final study contains recommendations for the location of GE equipment and associated devices, electrical wiring and room arrangements. When preparing the study, every effort has been made to consider every aspect of the actual equipment expected to be installed.\u003Cbr>· The layout of the equipment offered by GE, the dimensions given for the premises, the details provided for the pre-installation work and electrical power supply are given according to the information noted during on-site study and the wishes expressed by the customer.\u003Cbr>· The room dimensions used to create the equipment layout may originate from a previous layout and may not be accurate as they may not have been verified on site. GE cannot take any responsibility for errors due to lack of information.\u003Cbr>· Dimensions apply to finished surfaces of the room.\u003Cbr>· Actual configuration may differ from options presented in some typical views or tables.\u003Cbr>· If this set of final drawings has been approved by the customer, any subsequent modification of the site must be subject to further investigation by GE about the feasibility of installing the equipment. Any reservations must be noted.\u003Cbr>· The equipment layout indicates the placement and interconnection of the indicated equipment components. There may be local requirements that could impact the placement of these components. It remains the customer's ","cbCaiaxiy7UQXvlL","https://ap.wps.com/l/cbCaiaxiy7UQXvlL","pdf",1508056,18,"English","# Revision and Document Notes\n## Site Disclaimer and General Specifications\n## Customer Responsibilities\n## Radio-Protection\n## Required Manuals and Site Readiness Requirements","[{\"question\":\"Which manual is mandatory for using this drawing set?\",\"answer\":\"The document states that a mandatory component of the drawing set is the GE HealthCare Pre Installation manual. Failure to reference it may result in incomplete documentation required for site design and preparation.\"},{\"question\":\"What responsibility does GE HealthCare disclaim regarding damages and drawing changes?\",\"answer\":\"GE HealthCare does not take responsibility for damages resulting from changes made by others, errors from not referring to the complete set, or damage from partial use of final issue drawings. It also rejects responsibility for defective work due to scaling from these drawings.\"},{\"question\":\"Who must determine suitable radio-protection?\",\"answer\":\"Suitable radiological protection must be determined by a qualified radiological physicist in conformation with local regulations, and GE does not take responsibility for the specification or provision of radio-protection.\"}]","GE HealthCare Revolution RT - Final Study - Mandatory Component | PDF",1792753978,45]