[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641324-105":59,"doc-detail-641324-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","gas-furnace-category-1-instruction-manual","GAS FURNACE - CATEGORY 1 - Instruction Manual","","Instruction manual for Gas Furnaces, Category 1 (Category I). It outlines compliance with ANSI Z21.47/CSA 2.3 and provides critical safety guidance for installers, emphasizing training, hazard awareness during installation and repair, and responsibility for safe operation. Sections include safety considerations, shipping inspection, ESD precautions, product application, location and installation positions, combustion and ventilation air requirements, and Category I venting, followed by electrical connections, gas supply and piping, ductwork filters, and sequence of operation for integrated ignition control.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/gas-furnace-category-1-instruction-manual/641324/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/gas-furnace-category-1-instruction-manual/641324.png","ImageObject",300,407,{"name":92,"@type":93},"Danger Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-06","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What does the manual emphasize for installing personnel before installation?","Question",{"text":113,"@type":114},"Installers must thoroughly familiarize themselves with the instruction manual before performing actual installation. The manual stresses paying close attention to safety warnings and recognizing that installation or repair can be more hazardous than normal operation.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the manual handle conflicts with existing safety practices?",{"text":118,"@type":114},"The precautions in the installation manual are intended to supplement existing practices. If a direct conflict exists, the precautions listed in the manual take precedence.",{"name":120,"@type":111,"acceptedAnswer":121},"Which parts of the installation process are covered besides safety warnings?",{"text":122,"@type":114},"The manual includes product application, location and installation positions, combustion and ventilation air requirements including Category I venting, and then electrical connections, gas supply and piping, ductwork filtration, and the sequence of operation for the integrated ignition control.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},641324,1793047528,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":36,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},962090769052,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","*MES80/*CES80  \nGAS FURNACE-CATEGORY 1 CATÉGORIE I  \nThese furnaces comply with requirements embodied in the American National Standard / National Standard of Canada ANSI Z21 .47·CSA-2 .3 Gas Fired Central Furnaces.  \nATTENTION INSTALLING PERSONNEL  \nAs a professional installer, you have an obligation to know the product better than the customer. This includes all safety precautions and related items.  \nPrior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation or repair, it is possible to place yourself in a position which is more hazardous than when the unit is in operation.  \nRemember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use.  \nSafety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific, good safety practices...follow them.  \nThe precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence.  \nRECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION  \nNOTE: Please contact your distributor or our website listed below for the applicable Specification Sheet referred to in this manual.  \n| PROP 65 WARNING\u003Cbr>FOR CALIFORNIA CONSUMERS |  |\n| --- | --- |\n| |  |\n| Cancer and Reproductive Harm\u003Cbr>[www. P65Warnings.ca.gov](www. P65Warnings.ca.gov) | 0140M00517-A |\n\nInstaller: Affix all manuals adjacent to the unit.  \nIndex  \nSAFETY CONSIDERATIONS............................................ 3  \nAdditional Safety Considerations....................................... 4  \nShipping Inspection........................................................... 4  \nElectrostatic Discharge (ESD) Precautions....................... 5  \nTo The Installer.................................................................. 5  \nPRODUCT APPLICATION................................................. 5  \nLOCATION REQUIREMENTS AND CONSIDERATIONS .6 Clearances and Accessibility............................................. 7  \nInstallation Positions.......................................................... 7  \nHorizontal Installation........................................................ 8  \nFurnace Suspension......................................................... 8  \nExisting Furnace Removal................................................ 8  \nThermostat Location......................................................... 9  \nCOMBUSTION AND VENTILATION AIR REQUIREMENTS...........................................................................................9  \nCATEGORY I VENTING (VERTICAL VENTING) ............ 10  \nONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL, ADJUST, SERVICE OR REPAIR (HEREINAFTER,“SERVICE”) THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD SERVICE THE EQUIPMENT. THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES. IF YOU SERVICE THIS UNIT, YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY RESULT. IN ADDITION, IN JURISDICTIONS THAT REQUIRE ONE OR MORE LICENSES TO SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL, ONLY LICENSED PERSONNEL SHOULD SERVICE THE  \nEQUIPMENT. IMPROPER INSTALLATION, ADJUSTMENT, SERVICING OR REPAIR OF THE EQUIPMENT SPECIFIED IN THIS MANUAL, OR ATTEMPTING TO INSTALL, ADJUST, SERVICE OR REPAIR THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT PROPER TRAINING MAY RESULT IN PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.  \nIOG-2021D 03/2020  \n19001 Kermier Rd.  \nWaller, TX 77484  \n[www.goodmanmfg.com](www.goodmanmfg.com) • [www.amana-hac.com](www.amana-hac.com)  \n© 2019-2020 Goodman Manufacturing Company, L. P.  \n ® is a registered trademark of Maytag Corporation or its related companies and is used under license. All right","cbCaioXht2nq98kK","https://ap.wps.com/l/cbCaioXht2nq98kK","pdf",2210574,"English","# SAFETY CONSIDERATIONS\n## Additional Safety Considerations\n## Shipping Inspection\n## Electrostatic Discharge (ESD) Precautions\n## To The Installer\n# PRODUCT APPLICATION\n## LOCATION REQUIREMENTS AND CONSIDERATIONS\n## COMBUSTION AND VENTILATION AIR REQUIREMENTS\n## CATEGORY I VENTING (VERTICAL VENTING)\n# ELECTRICAL CONNECTIONS\n## Wiring Harness\n## 115 Volt Line Connections\n## 24 Volt Thermostat Wiring\n# GAS SUPPLY AND PIPING\n## High Altitude Derate\n## Propane Gas Conversion\n# DUCTWORK\n## Filters-Read This Section Before Installing The Return Air Ductwork\n# SEQUENCE OF OPERATION (INTEGRATED IGNITION CONTROL)\n## Power Up\n## Heating Mode","[{\"question\":\"What does the manual emphasize for installing personnel before installation?\",\"answer\":\"Installers must thoroughly familiarize themselves with the instruction manual before performing actual installation. The manual stresses paying close attention to safety warnings and recognizing that installation or repair can be more hazardous than normal operation.\"},{\"question\":\"How does the manual handle conflicts with existing safety practices?\",\"answer\":\"The precautions in the installation manual are intended to supplement existing practices. If a direct conflict exists, the precautions listed in the manual take precedence.\"},{\"question\":\"Which parts of the installation process are covered besides safety warnings?\",\"answer\":\"The manual includes product application, location and installation positions, combustion and ventilation air requirements including Category I venting, and then electrical connections, gas supply and piping, ductwork filtration, and the sequence of operation for the integrated ignition control.\"}]","GAS FURNACE - CATEGORY 1 - Instruction Manual | PDF",1792713630,101]