[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662339-105":59,"doc-detail-662339-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","g32q-series-units-installation-instructions-gas-units","G32Q Series Units - Installation Instructions - Gas Units","","Installation instructions for Lennox G32Q series gas units, including safety warnings and what to do if gas is smelled. Covers required installation and service by qualified personnel, detailed guidance for unit dimensions and parts arrangement, requirements for return air openings, filters and optional filter assembly, duct system and vent piping guidelines, joint cementing and venting practices. Also includes gas piping, electrical installation, start-up procedures, heating sequence of operation, gas pressure adjustment, high altitude information, unit adjustments, service, repair parts, troubleshooting, and start-up & performance checklist.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/g32q-series-units-installation-instructions-gas-units/662339/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/g32q-series-units-installation-instructions-gas-units/662339.png","ImageObject",300,407,{"name":92,"@type":93},"Dipper","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What should be done if gas is smelled?","Question",{"text":112,"@type":113},"Do not try to light any appliance. Extinguish open flames, avoid electrical switches or phones in the building, call the gas supplier from a neighbor’s phone, and if unreachable, call the fire department.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Who must perform installation and service?",{"text":117,"@type":113},"Installation and service must be performed by a qualified installer, service agency, or the gas supplier.",{"name":119,"@type":110,"acceptedAnswer":120},"What clearance requirements are listed for combustible materials?",{"text":121,"@type":113},"Table 1 specifies service access front clearance of 24 in. (610 mm) and top clearance to combustible materials of 1 in. (25 mm), with side, rear, and front listed as 0, exhaust as 0, and floor as 0* with the stated note for combustible floors.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662339,1793212221,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},1374404997633,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","LENNOX  \n2001 Lennox Industries inc.  \nDallas.Texas.USA  \nRETAIN THESE INSTRUCTIONSFOR FUTURE REFERENCE  \n11/01  \nDo not store or use gasoline or otherflammable vapors and liquids in the vi-cinity of this or any other appliance.  \nInstallation and service must be per-formed by a qualified installer,serviceagency or the gas supplier.  \n504,488M  \n11/2001  \nSupersedes 504,382M  \n\n|  | A WARNING   |\n| --- | --- |\n|  | If the information in this manual is not  \u003Cbr>followed exactly,a fire or explosion  \u003Cbr>may result causing property damage,  \u003Cbr>personal injury or death.   |\n|  |  |\n\nWHAT TO DOIF YOU SMELL GAS:  \n● Do not try to light any appliance.  \n● Extinguish any open flames.  \n●Do not touch any electrical switch;do not useany phone in your building.  \n● Immediately call your gas supplier from aneighbor's phone.Follow the gas supplier'sinstructions.  \n● If you cannot reach your gas supplier,call thefire department.  \n# INSTALLATIONINSTRUCTIONS\n\nG32Q SERIES UNITS  \nGAS UNITS  \nTable of Contents  \nUnit Dimensions.       ……       2G32Q Parts Arrangement ...  …...…....3Requirements...............................4General....................................5installation-Setting Equipment.     ……5Return Air Opening Guidelines.........   …..5Fiters &Optional Fiter Assembly....…    ...6Duct System.…    …….….....7Pipe &Fittings Specifications ......…     ...7Vent Piping Guidelines ...…     ...  ..…....8Joint Cementing Procedure ..........    .....8Venting Practices..................  …  ...9Gas Piping……….....…........15Electrical.....................................16Unit Start-Up...   …  …     …   .21Heating Sequence of Operation ............22Blower Operation.     ..……......22Gas Pressure Adjustment .....................22High Altitude Information ...........  ......23Other Unit Adjustments .........  ……    .23Service..................................24Repair Parts..          ……     .   .27Troubleshooting….....    ....……..27Start-Up &Performance Checklist ....…    ...32  \n504,488M  \n| Model No.   | A   |  | B   |  | C   |  | D   |  | E   |  | F   |  | G   |  | H   |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | in.   | mm   | in.   | mm   | in.   | mm   | in.   | mm   | in.   | mm   | in.   | mm   | in.   | mm   | in.   | mm   |\n| G32Q3-75   | 16-1/4   | 413   | 14-1/8   | 359   | 12   | 305   | 12   | 305   | 2-1/8   | 54   | 7-5/8   | 194   | 14   | 356   | 12-3/4   | 324   |\n| G32Q3/4-100  \u003Cbr>G32Q4/5-100   | 21-1/4   | 540   | 19-1/8   | 486   | 18   | 457   | 18   | 457   | 1~5/8   | 41   | 10-1/8   | 257   | 20   | 508   | 18-3/4   | 476   |\n| G32Q4/5-125   | 26-1/4   | 667   | 24-3/8   | 613   | 18   | 457   | 18   | 457   | 4-1/8   | 105   | 12-5/8   | 321   | 20   | 508   | 18-3/4   | 476   |\n\nLennox G32Q units are CSA International certified toANSI Z21.47 and CSA 2.3 standards.  \nIn the USA,installation of Lennox gas central funacesmust conform with local building codes.In the absence oflocal codes,units must be installed according to the cur-rent National Fuel Gas Code(ANSI-Z223.1)in the UnitedStates.The National Fuel Gas Code is available from thefollowing address:  \nAmerican National Standards Institute,Inc.11 West 42nd StreetNew York,NY 10036  \nIn Canada,installation must conform with curent Nation-al Standard of Canada CAN/CGA-B149.1 \"InstallationCode for Natural Gas Burning Appliances and Equip-ment\"and CAN/CGA-B149.2\"Installation Code for Pro-pane Gas Burning Appliances and Equipment,\"localplumbing or waste water codes and other applicable iocalcodes.  \nThis furnace is CSA International certified for installationclearances to combustible material as listed on the unitrating plate and in table 1.  \nTABLE 1  \n\n| Clearances   | Location   | Inches(mm)   |\n| --- | --- | --- |\n| Service access   | Front   | 24(610)   |\n|  | Condensate side   | 3(76)  \u003Cbr>(from side of unit)   |\n| To combustible  \u003Cbr>materials   | Top   | 1(25)   |\n|  | Exhaust   | 0   |\n|  ","cbCaifd2khqwmYE0","https://ap.wps.com/l/cbCaifd2khqwmYE0","pdf",1838293,32,"English","# Installation Instructions\n## G32Q Series Units - Gas Units\n## Unit Dimensions\n## Requirements\n## General\n## Installation - Setting Equipment\n## Return Air Opening Guidelines\n## Filters & Optional Filter Assembly\n## Duct System\n## Pipe & Fittings Specifications\n## Vent Piping Guidelines\n## Joint Cementing Procedure\n## Venting Practices\n## Gas Piping\n## Electrical\n## Unit Start-Up\n## Heating Sequence of Operation\n## Blower Operation\n## Gas Pressure Adjustment\n## High Altitude Information\n## Other Unit Adjustments\n## Service\n## Repair Parts\n## Troubleshooting\n## Start-Up & Performance Checklist","[{\"question\":\"What should be done if gas is smelled?\",\"answer\":\"Do not try to light any appliance. Extinguish open flames, avoid electrical switches or phones in the building, call the gas supplier from a neighbor’s phone, and if unreachable, call the fire department.\"},{\"question\":\"Who must perform installation and service?\",\"answer\":\"Installation and service must be performed by a qualified installer, service agency, or the gas supplier.\"},{\"question\":\"What clearance requirements are listed for combustible materials?\",\"answer\":\"Table 1 specifies service access front clearance of 24 in. (610 mm) and top clearance to combustible materials of 1 in. (25 mm), with side, rear, and front listed as 0, exhaust as 0, and floor as 0* with the stated note for combustible floors.\"}]","G32Q Series Units - Installation Instructions - Gas Units | PDF",81]