[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663428-105":59,"doc-detail-663428-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","g-n-mohan-kumar-single-line-diagram-electrical-panel-supply-and-distribution","G. N. MOHAN KUMAR SINGLE LINE DIAGRAM - Electrical panel supply and distribution","","Electrical single line diagram covering power supply and distribution for multiple hostels and panels, referencing EXTG. CT METER (SC 408), a NEW LADIES HOSTEL-A 250 ATP+N, and an on/off switch from 35 kVA DG set. Includes ratings and switching components such as change-over switches, 250A 4-pole, 63A TP+N, MCCBs, and multiple distribution boards across GF/1F/2F/3F with lighting/power circuits. Notes identify existing loads and circuit groupings (C1–C24).",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/g-n-mohan-kumar-single-line-diagram-electrical-panel-supply-and-distribution/663428/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/g-n-mohan-kumar-single-line-diagram-electrical-panel-supply-and-distribution/663428.png","ImageObject",300,407,{"name":92,"@type":93},"Rainbow Cat","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What power source and metering references are included in the diagram?","Question",{"text":112,"@type":113},"The diagram references EXTG. CT METER (SC 408) and power supply from a 35 kVA DG set with an on/off switch.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which key distribution and switching components are shown?",{"text":117,"@type":113},"It shows change-over switching (250A 4-pole change over switch), LS and MCCBs, and multiple 63A TP+N indications.",{"name":119,"@type":110,"acceptedAnswer":120},"How are lighting and power circuits organized in this diagram?",{"text":121,"@type":113},"Lighting/power circuits are grouped into labeled circuits such as C1–C24, with repeated lighting/power circuit blocks and existing load references.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663428,1793227700,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962090769181,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","| SUPPLY FROM\u003Cbr>EXTG. CT METER (SC 408)\u003Cbr>NEW LADIES\u003Cbr>HOSTEL A 250 ATP+N\u003Cbr>ON/OFF SWITH\u003Cbr>FROM 35 KVA\u003Cbr>DG SET\u003Cbr>MAIN LT PANEL GENTS HOSTEL C\u003Cbr>\u003Cbr>(EXISTING)\u003Cbr>250 A 4 POLE CHANGE OVER SWITCH\u003Cbr>\u003Cbr>|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | |  | 63A\u003Cbr>TP+N | |  | 63A\u003Cbr>TP+N | |  | 63A\u003Cbr>TP+N | |  | 63A\u003Cbr>TP+N | |  | 63A\u003Cbr>TP+N |  |\n|  |  |  |  |  |  |  |  |  |  |  | \u003Cbr>200A 125A 125A 125A 125A 200A 125A\u003Cbr>TPN\u003Cbr>\u003Cbr>TPN\u003Cbr>\u003Cbr>TPN\u003Cbr>\u003Cbr>TPN\u003Cbr>\u003Cbr>TPN\u003Cbr>\u003Cbr>TPN\u003Cbr>\u003Cbr>TP+N\u003Cbr>|  |  |  |  |  |  | LS |  | MCCB |  |  | MCCB |  |  | MCCB |  |  | MCCB |  |  | MCCB |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | OND .\u003Cbr>LS |  |  | OND .\u003Cbr>LS |  |  | OND .\u003Cbr>LS |  |  | OND . |  |  |  |  |  |\n| \u003Cbr>4R 16 + 2R 4 Sq . mm FR CU . WIRE IN 40 Ø PVC C\u003Cbr>4R 16 + 2R 4 Sq . mm FR CU . WIRE IN 40 Ø PVC C\u003Cbr>4R 16 + 2R 4 Sq . mm FR CU . WIRE IN 40 Ø PVC C\u003Cbr>4R 10 + 2R 4 Sq . mm FR CU . WIRE IN 32 Ø PVC C\u003Cbr>OLD LIBRARY LDB\u003Cbr>NEW LIBRARY\u003Cbr>GENTS HOSTEL-D\u003Cbr>NEW LADIES HOSTEL-A\u003Cbr>OLD LADIES HOSTEL-B & C\u003Cbr>PANEL BOARD 3\u003Cbr>GF DB 1\u003Cbr>1F DB 2\u003Cbr>2F DB 3\u003Cbr>L IFT\u003Cbr>SPARE\u003Cbr>10/16/25A\u003Cbr>10/16/25A\u003Cbr>10/16/25A\u003Cbr>10/16/25A\u003Cbr>10/16/25A\u003Cbr>10/16/25A\u003Cbr>10/16/25A\u003Cbr>10/16/25A\u003Cbr>10/16/25A |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  | FT |  |  |  |  |  |  |  |  |  | LTG . CCT\u003Cbr>LAP TOP 6A . CCT\u003Cbr>LTG . CCT\u003Cbr>-SPLIT AC\u003Cbr>LTG . CCT\u003Cbr>LTG . CCT\u003Cbr>SPLIT . CCT\u003Cbr>-SPLIT AC\u003Cbr>LAP TOP 6A . CCT\u003Cbr>LTG . CCT\u003Cbr>SPLIT AC\u003Cbr>-SPARE\u003Cbr>-LTG . CCT\u003Cbr>-LAP TOP 6A . CCT\u003Cbr>-SPLIT AC\u003Cbr>-SPARE\u003Cbr>-LTG . CCT\u003Cbr>-LTG . CCT\u003Cbr>-SPLIT AC\u003Cbr>-SPARE\u003Cbr>-LAP TOP 6A . CCT\u003Cbr>-SPLIT AC\u003Cbr>-SPLIT AC\u003Cbr>-SPARE\u003Cbr>LTG . CCT\u003Cbr>LAP TOP 6A . CCT\u003Cbr>LTG . CCT\u003Cbr>-SPLIT AC\u003Cbr>LTG . CCT\u003Cbr>LTG . CCT\u003Cbr>SPLIT . CCT\u003Cbr>-SPLIT AC\u003Cbr>LAP TOP 6A . CCT\u003Cbr>LTG . CCT\u003Cbr>SPLIT AC\u003Cbr>-SPARE |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| SOLAR\u003Cbr>3F PDB\u003Cbr>A BLOCK LI\u003Cbr>3F LDB\u003Cbr>SPARE\u003Cbr>FIRE PUMP\u003Cbr>GF PDB\u003Cbr>1F PDB\u003Cbr>2F LDB\u003Cbr>GF LDB\u003Cbr>SPARE\u003Cbr>C1-C4-C7-C10\u003Cbr>\u003Cbr>C2-\u003Cbr>C5-\u003Cbr>C8-\u003Cbr>C11\u003Cbr>C3-\u003Cbr>C6-\u003Cbr>C9-\u003Cbr>C12\u003Cbr>LIGHTING/POWER CIRCUITS \u003Cbr>C13 C16 C19 C22\u003Cbr>\u003Cbr>C14\u003Cbr>C17\u003Cbr>C20\u003Cbr>C23\u003Cbr>C15\u003Cbr>C18\u003Cbr>C21\u003Cbr>C24\u003Cbr>LIGHTING/POWER CIRCUITS \u003Cbr> LIGHTING/POWER CIRCUITS \u003Cbr>C1-\u003Cbr>C4-\u003Cbr>C7-\u003Cbr>C10\u003Cbr>C2-\u003Cbr>C5-\u003Cbr>C8-\u003Cbr>C11\u003Cbr>C3-\u003Cbr>C6-\u003Cbr>C9-\u003Cbr>C12\u003Cbr>EXISTING LOADS EXISTING LOADS |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| NOTES\u003Cbr>|  |  |  |  |  |  | | |  |  |  |  |  | MADRAS SCHOOL OF ECONOMICS NEW CLASS ROOM |  |  |  |  |  |  |  |  |  | TC Designers\u003Cbr>\u003Cbr>J.2,\"Maxis. Presidium\" New \\# 2,Old \\# 63/1, LBlock,24 th street, Anna Nagar East, Chennai. 600 102. [ctcdesign@yahoo.com](ctcdesign@yahoo.com)\u003Cbr>\u003Cbr>|  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  | \u003Cbr>G. N. MOHAN KUMAR SINGLE LINE DIAGRAM |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |","cbCaiuRJb6rghuhJ","https://ap.wps.com/l/cbCaiuRJb6rghuhJ","pdf",226008,"English","# Electrical Supply Overview\n## CT meter and DG set references\n# Distribution Boards and Panels\n## GF/1F/2F/3F DBs and LDBs\n# Switching and Protection Devices\n## Change-over switches, LS, MCCB\n# Circuits and Load Classification\n## Lighting/power circuits C1–C24\n# Existing Loads and Notes\n## Existing load list and reference notes","[{\"question\":\"What power source and metering references are included in the diagram?\",\"answer\":\"The diagram references EXTG. CT METER (SC 408) and power supply from a 35 kVA DG set with an on/off switch.\"},{\"question\":\"Which key distribution and switching components are shown?\",\"answer\":\"It shows change-over switching (250A 4-pole change over switch), LS and MCCBs, and multiple 63A TP+N indications.\"},{\"question\":\"How are lighting and power circuits organized in this diagram?\",\"answer\":\"Lighting/power circuits are grouped into labeled circuits such as C1–C24, with repeated lighting/power circuit blocks and existing load references.\"}]","G. N. MOHAN KUMAR SINGLE LINE DIAGRAM - Electrical panel supply and distribution | PDF"]