[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-463358-105":59,"doc-detail-463358-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","fuzzy-adaptive-eso-control-for-dual-active-bridge-converters","Fuzzy-Adaptive ESO Control for Dual Active Bridge Converters","","In converter-dominated DC microgrids, sudden load transients can create large voltage deviations on the common DC bus. An energy storage system with an isolated bidirectional dual active bridge converter is used as the power interface, but the controller must preserve robustness under step-load changes. The work introduces a fuzzy-logic active disturbance rejection control framework that adaptively tunes the extended state observer bandwidth, increasing it during transients to speed disturbance compensation and reducing it near steady state to limit noise amplification. Hardware load-step experiments demonstrate significant reductions in voltage deviation metrics versus PI and fixed-bandwidth observers.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/fuzzy-adaptive-eso-control-for-dual-active-bridge-converters/463358/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/fuzzy-adaptive-eso-control-for-dual-active-bridge-converters/463358.png","ImageObject",300,407,{"name":92,"@type":93},"Indoniesian Boy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is adaptive control needed for dual active bridge converters in DC microgrids?","Question",{"text":112,"@type":113},"Step-like load and generation variations in DC microgrids can cause common DC-bus voltage deviations. The controller must balance robustness with fast transient restoration while handling uncertainties like model mismatch, sensor noise, and delays.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the proposed method tune the ESO bandwidth?",{"text":117,"@type":113},"It uses fuzzy logic based on the estimation error to adaptively adjust the extended state observer bandwidth. The bandwidth is increased during transients to accelerate disturbance compensation and decreased near steady state to suppress noise amplification.",{"name":119,"@type":110,"acceptedAnswer":120},"What improvements were validated in hardware experiments?",{"text":121,"@type":113},"Under load increase, peak voltage undershoot and settling time are reduced by 22% and 48.9% versus a PI controller, and by 20% and 36.1% versus a fixed-bandwidth observer. Under load decrease, peak overshoot and settling time are reduced by 27.9% and 49.5% versus PI, and by 20.5% and 25% versus the fixed-bandwidth observer.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},463358,1790820660,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962090760608,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Article  \nFuzzy-Adaptive ESO Control for Dual Active Bridge Converters Ju-Hyeong Seo  and Sung-Jin Choi *  \nAcademic Editor: Paolo Mercorelli  \nReceived: 19 November 2025  \nRevised: 16 December 2025  \nAccepted: 18 December 2025  \nPublished: 20 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \nDepartment of Electrical, Electronic and Computer Engineering, University of Ulsan, Ulsan 44610, Republic of Korea; [chris3342@mail.ulsan.ac.kr](chris3342@mail.ulsan.ac.kr)  \n* Correspondence: [sjchoi@ulsan.ac.kr](sjchoi@ulsan.ac.kr)  \nAbstract  \nIn converter-dominated direct-current microgrids, severe load transients can cause large voltage deviations on the common direct-current bus. To mitigate this, an energy storage system is typically employed, and an isolated bidirectional dual active bridge converter is commonly used as the power interface. Therefore, the controller must ensure robust transient performance under step-load conditions. This paper proposes an active disturbance rejection control framework that adaptively adjusts the bandwidth of an extended state observer using fuzzy logic. The proposed observer increases its bandwidth during transients—based on the estimation error—to accelerate disturbance compensation, while decreasing the bandwidth near steady state to suppress noise amplification. This adaptive tuning alleviates the fixed-bandwidth trade-off between transient speed and noise sensitivity in ESO-based regulation. Hardware experiments under load-step conditions validate the method: for a load increase, the peak voltage undershoot and settling time are reduced by 22% and 48.9% relative to a proportional–integral controller, and by 20% and 36.1% relative to a fixed-bandwidth observer. For a load decrease, the peak overshoot and settling time are reduced by 27.9% and 49.5% compared with the proportional–integral controller, and by 20.5% and 25% compared with the fixed-bandwidth observer.  \nKeywords: active disturbance rejection control (ADRC); adaptive bandwidth; DC microgrids (DCMG); dual active bridge (DAB); extended state observer (ESO); fuzzy logic  \n1. Introduction  \nRecently, driven by carbon-neutrality targets and the efficiency requirements of powerelectronics-dominated systems, DC microgrids (DCMGs) are gaining traction across applications such as data centers, transportation electrification, and industrial facilities [1] . Compared with ac distribution, DC architectures avoid frequency and phase synchronization requirements, reduce issues related to reactive-power flows and harmonics/unbalances, and interface naturally with renewable sources, power-electronic loads, and energy storage systems (ESS) [1,2] . In particular, in islanded or weakly grid-tied DCMGs, rapid variations in load and generation can induce deviations of the common DC-bus voltage; thus, tight regulation and fast restoration to the nominal reference become key control objectives for power quality and reliability [3–5] . To mitigate these power imbalances, an ESS is commonly integrated to buffer fast dynamics [6] . As a bidirectional power interface between the ESS and the DC bus, the dual active bridge (DAB), an isolated bidirectional DC/DC converter, is widely used [7,8] . The DAB offers high-frequency galvanic isolation, high power conversion efficiency over a wide operating range, and flexible power flow control through various modulation techniques such as single-phase-shift (SPS) and triple-phase-shift  \n(TPS) [9–14] . Moreover, accurate average and discrete models have been established [11], along with frequency-domain zero-voltage switching (ZVS) boundary analysis [12] and phase-shift control methods for achieving fast dynamic response [13,14] . These modulation and control design guidelines have been systematically presented, and their reliability in high-power ap","cbCainuvalOTXYeq","https://ap.wps.com/l/cbCainuvalOTXYeq","pdf",10555154,18,"English","# Abstract\n# Introduction\n## DC microgrids and dual active bridge background\n## Control challenges and motivation\n## Proposed fuzzy logic-based ESO bandwidth adjustment","[{\"question\":\"Why is adaptive control needed for dual active bridge converters in DC microgrids?\",\"answer\":\"Step-like load and generation variations in DC microgrids can cause common DC-bus voltage deviations. The controller must balance robustness with fast transient restoration while handling uncertainties like model mismatch, sensor noise, and delays.\"},{\"question\":\"How does the proposed method tune the ESO bandwidth?\",\"answer\":\"It uses fuzzy logic based on the estimation error to adaptively adjust the extended state observer bandwidth. The bandwidth is increased during transients to accelerate disturbance compensation and decreased near steady state to suppress noise amplification.\"},{\"question\":\"What improvements were validated in hardware experiments?\",\"answer\":\"Under load increase, peak voltage undershoot and settling time are reduced by 22% and 48.9% versus a PI controller, and by 20% and 36.1% versus a fixed-bandwidth observer. Under load decrease, peak overshoot and settling time are reduced by 27.9% and 49.5% versus PI, and by 20.5% and 25% versus the fixed-bandwidth observer.\"}]","Fuzzy-Adaptive ESO Control for Dual Active Bridge Converters | PDF",1790766457,45,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/824ab598f8a2ef2e38707b0d3bbac9f8.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b592075437f19b7b3e46c28057356b39.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5a1f37aac646b80e02fd81b8d16ddc03.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ee837a1eb6211c52aa5efc415d9de4ba.webp",980,1385]