[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-670814-105":59,"doc-detail-670814-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","ft-351-technical-data-sheet","FT 351 - Technical Data Sheet","","Avery Dennison FT 351 is a differential double coated pure solvent acrylic/solvent rubber tape engineered for applications demanding extreme adhesion to low surface energy substrates on the laminating side, while providing a plasticizer resistant and repositionable adhesive layer on the mounting side. It is suitable for bonding polyurethane foam, polyester fibers, felts, and fabrics to diverse substrates, including cable wrap uses, die-cut parts, nameplates, and decorative trims. The sheet details construction materials, adhesive thickness and caliper, peel adhesion, loop tack, static shear, temperature limits, application techniques, and storage shelf life.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ft-351-technical-data-sheet/670814/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ft-351-technical-data-sheet/670814.png","ImageObject",300,407,{"name":92,"@type":93},"lugxt","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02","2026-11-01",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What makes the FT 351 adhesive system differential?","Question",{"text":112,"@type":113},"The mounting side uses cross-linked acrylic based adhesive for plasticizer resistance and initial repositionability, while the laminating side provides high initial adhesion to low surface energy (LSE) substrates.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the typical service temperature limits for FT 351?",{"text":117,"@type":113},"The maximum service temperature is 110°C, with a minimum service temperature of -40°C. Minimum application temperature is 10°C.",{"name":119,"@type":110,"acceptedAnswer":120},"How should FT 351 be applied and stored to maintain performance?",{"text":121,"@type":113},"Apply to a clean, dry, grease- and oil-free surface, and recognize that bond strength depends on adhesive-to-surface contact plus pressure, time, and temperature. Store for up to two years at 18–22°C (64–72°F) and 30–70% relative humidity, out of direct sunlight, in original packaging.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},670814,1793571826,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":24},3985747862600,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","-  \nTECHNICAL DATA SHEET  \nAvery Dennison™ FT 351 is a differential double coated pure solvent acrylic/solvent rubber tape, designed for applications where an extreme adhesion is required to low surface energy materialson the laminating side and where the mounting side requires a plasticizer resistant andrepositionable adhesive layer. Ideally used for bonding polyurethane foam, polyester ﬁ bers, feltsand fabrics to a wide variety of substrates. Typically designed for cable wrap applications with a PU-foam, high precision die-cut parts, nameplates, decorative trims and proﬁ les.  \nFEATURES  \n● High tack laminating adhesive  \n● Differential adhesive system  \n● Service temperature up to 110°C  \n● Easy release glassine liner  \n● Strong, conformable ﬁ lmic carrier  \nBENEFITS  \n● Mounting side: cross-linked acrylic based adhesive providing excellent resistance against plasticizers and offering initial repositionability when mounted  \n● Laminating side: high initial adhesion to a wide variety of LSE substrates  \n● Suitable for high temperature bonding applications  \n● Reinforces ﬂexible substrates and acts as a barrier for highly plasticized substrates  \n● Improved die-cutting characteristics  \n● Facilitates easy removal at point of application  \nCONSTRUCTION  \nLiner: Havana (yellow/brown) glassine  \nAdhesive 1: Pure solvent acrylic  \nCarrier: Transparent polyester ﬁ lm 12 μm  \nAdhesive 2: Solvent rubber  \nClassification: Avery Dennison-Public  \nAdhesive Properties Typical Values  \nTHICKNESS (ASTM D3652) US Mils MM’s Micron’s (µm)  \nLiner 2.95 0.075 75  \nCarrier & Adhesive 3.62 0.092 92  \nTotal Caliper 6.57 0. 167 167  \nPEEL ADHESION (ASTM D3330)  \n180 ˚ ( 12”) 300 mm / min @ Room Temp SUBSTRATE Lbf / in US Oz / In N / Meter Stainless Steel Liner 24 hr dwell 2.9 46 500  \nUnwind 24 hr dwell 5.5 89 970  \nABS Liner 24 hr dwell 3.6 58 630  \nUnwind 24 hr dwell 5. 1 82 900  \nPolypropylene Liner 24 hr dwell 1.6 26 280  \nUnwind 24 hr dwell 3.8 60 660  \nLOOP TACK (ASTM D6195)  \n( 12”) 300 mm / min @ Room Temp SUBSTRATE Lbf / in US Oz / In N / Meter Stainless Steel Liner Initial 3. 1 540  \nUnwind Initial 6.3 1100  \nSTATIC SHEAR (ASTM D3654)  \n1”sq (6 .25 cm2) 1000 g @ Room Temp  \nSUBSTRATE Min to Fail  \nFoil; 1\" sq (6 .5 cm2); 1000 g Liner 24 hr dwell > 600  \nUnwind 24 hr dwell > 7500  \nTEMPERATURES ˚F ˚C  \nMinimum Application Temperature 50 ˚ F 10 ˚C  \nMinimum Service Temperature -40 ˚ F -40 ˚C  \nMaximum Service Temperature 230 ˚ F 110 ˚C  \nNote: The listed values are typical only and not intended to serve as product speciﬁcations  \nAPPLICATION TECHNIQUES  \n● It is essential , as with all pressure-sensitive tapes, that the surface to which the tape is applied be clean, dry, and free of grease or oil  \n● Bond strength is dependent upon the amount of adhesive-to-surface contact developed  \n● Note that different pressure, time and temperature on different (ﬁlm / rigid) surface achieves different performance  \nSTORAGE / SHELF LIFE  \nTwo years when stored at 64-72 º F ( 18-22 ºC) / 30-70 % relative humidity, out of direct sunlight and in original packaging.  \nFor more information on our bonding tapes and adhesive solutions, call us:  \nNorth America: +1 866 462 8379  \nAsia Paciﬁc: +86 512 57155001  \nEurope: +32 (0)14 40 48 11  \n[www.tapes.averydennison.com](www.tapes.averydennison.com)  \n©2020, Avery Dennison Corporation. Avery Dennison and the triangle logo are registered trademarks of Avery Dennison Corporation. All rights reserved.","cbCaiuaVLIZlpyXN","https://ap.wps.com/l/cbCaiuaVLIZlpyXN","pdf",345626,"English","# Features\n# Benefits\n# Construction\n# Adhesive Properties (Typical Values)\n## Peel Adhesion\n## Loop Tack\n## Static Shear\n# Temperatures\n# Application Techniques\n# Storage / Shelf Life","[{\"question\":\"What makes the FT 351 adhesive system differential?\",\"answer\":\"The mounting side uses cross-linked acrylic based adhesive for plasticizer resistance and initial repositionability, while the laminating side provides high initial adhesion to low surface energy (LSE) substrates.\"},{\"question\":\"What are the typical service temperature limits for FT 351?\",\"answer\":\"The maximum service temperature is 110°C, with a minimum service temperature of -40°C. Minimum application temperature is 10°C.\"},{\"question\":\"How should FT 351 be applied and stored to maintain performance?\",\"answer\":\"Apply to a clean, dry, grease- and oil-free surface, and recognize that bond strength depends on adhesive-to-surface contact plus pressure, time, and temperature. Store for up to two years at 18–22°C (64–72°F) and 30–70% relative humidity, out of direct sunlight, in original packaging.\"}]","FT 351 - Technical Data Sheet | PDF"]