[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-560838-105":59,"doc-detail-560838-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","fsp320-6f01-electrical-specification-320w-ac-power-supply","FSP320-6F01 - Electrical Specification - 320W AC Power Supply","","Specification for the 320WAC power supply model FSP320-6F01, including electrical requirements and performance targets. Defines input characteristics such as rated voltage, continuous input range, frequency range, input current, efficiency levels, inrush current, and low-power consumption under PSON signal low at 240Vac. Covers output characteristics for multiple rails (5Vsb/5V/12V/+16V/-16V/24V), including ripple and noise limits, power-on behavior, turn-on delay, dynamic load limitation, and hold-up time. Also lists protection functions (over-current, over-power, and short-circuit) plus environmental/environmental placeholders.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/fsp320-6f01-electrical-specification-320w-ac-power-supply/560838/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/fsp320-6f01-electrical-specification-320w-ac-power-supply/560838.png","ImageObject",300,407,{"name":92,"@type":93},"Nguyễn Văn Học","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-22","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the input voltage and frequency ranges for FSP320-6F01?","Question",{"text":112,"@type":113},"The rated input voltage is 100V/240V. The continuous input voltage range is 90VAC to 264VAC, with an input frequency range of 47Hz to 63Hz.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What efficiency and inrush current requirements apply?",{"text":117,"@type":113},"Efficiency must be at least 82% at 100Vac full load and at least 86% at 240Vac full load. Inrush current at cold start (25°C) is specified as less than 100A.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the power supply protect against faults?",{"text":121,"@type":113},"It provides over-current protection with shutdown and latch mode behavior, over-power protection with shutdown and auto recovery, and short-circuit protection that triggers shutdown with auto recovery for 5Vsb/5V and latch mode for 12V/16V/-16V/24V.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},560838,1791830723,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},1374402739827,"https://ap-avatar.wpscdn.com/avatar/14000c97e7351f1a627?x-image-process=image/resize,m_fixed,w_180,h_180&k=1787885694763230660","全漢企業股份有限公司 SPI Electronic Co . Ltd .  \n台灣 桃園市建國東路22號  \nNo.22,Jianguo E, Rd .,Taoyuan City, Taiwan,R.O .C. TEL:+886-3-375-9888 FAX:+886-3-375-6966  \nSPECIFICATION  \n320WAC power supply FSP320-6F01 Apr.014 ‘05  \n\n| P.E | R/D | APPROVED | REV. |\n| --- | --- | --- | --- |\n| Larry Chang | Jaron Lin\u003Cbr>Paul Chu | LJ Wei | 001 |\n\n表單編號：7000P-0105  \n\n| |  | Electrical Specification |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| History |  |  |  |  |  |  |  |\n| REV. | Description |  | Date | Drawn | Mechanical | Electrical | Approved |\n| 000 | SPEC. ISSUE |  | Jan.25 ‘05 | Gigi Yu | Sum Chen | Jaron Lin\u003Cbr>Paul Chu | LJ. Wei |\n| 001 | SPEC. REVISE |  | Apr.14’05 | Gigi Yu | Sum Chen | Jaron Lin\u003Cbr>Paul Chu | LJ. Wei |\n|  |  |  |  |  |  |  |  |\n| MODEL NO. FSP320-6F01 SHEET  1  OF  6  |  |  |  |  |  |  |  |\n\n\n| |  | Electrical Specification |  |\n| --- | --- | --- | --- |\n| Electrical Requirements |  |  |  |\n| 1. Input Characteristics: ※Measured the output voltage at the PCB |  |  |  |\n| ITEM | CONDITION |  | SPECIFICATION |\n| 1.1 Rated Input Voltage |  |  | 100V / 240V |\n| 1.2 Input Voltage Range | Continuously |  | 90VAC to 264VAC |\n| 1.3 Input Frequency Range | Continuously |  | 47Hz to 63Hz |\n| 1.4 Input Current | 90Vac / full load |  | ≤4.3A |\n| 1.5 Efficiency: | 100Vac / full load\u003Cbr>240Vac / full load |  | ≥ 82%\u003Cbr>≥ 86% |\n| 1.6 Inrush Current | 100Vac / 220Vac\u003Cbr>at 25 . Cold Start |  | \u003C100A |\n| 1.7 Power Consumption (Power saving) | It must be measured in PSON signal is low condition at 240Vac & 5Vsb no load. ( Measured by HIOKI 3332 ) |  | ≤1W |\n|  |  |  |  |\n| MODEL NO. FSP320-6F01 SHEET  2  OF  6  |  |  |  |\n\n\n| |  |  |  |  | Electrical Specification |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 2. Output Characteristics: ※Measured the output voltage at the PCB |  |  |  |  |  |  |  |  |  |  |  |\n| ITEM |  |  | CONDITION |  |  |  |  |  | SPECIFICATION |  |  |\n| 2.1 Output Rated Voltage : |  |  |  |  |  |  |  |  |  |  |  |\n| a. PWR-ON signal is L |  |  |  |  |  |  |  |  |  |  |  |\n| No. | Symbol | Output Current | Output Ripple |  |  | Output Noise | Min.(V) | Typ. (V) |  | Max.(V) | Remark |\n| 1 | 5Vsb | 0.01A ~ 1.3A | 50mV |  |  | 100mV | 4.75 | 5.0 |  | 5.25 |  |\n| b. PWR-ON signal is H |  |  |  |  |  |  |  |  |  |  |  |\n| No. | Symbol | Output Current | Output Ripple |  |  | Output Noise | Min.(V) | Typ. (V) |  | Max.(V) | Remark |\n| 1 | 5Vsb | 0.01A ~ 1.3A | 50mV |  |  | 100mV | 4.75 | 5.0 |  | 5.25 |  |\n| 2 | 5V | 0.4A ~ 1.9A | 50mV |  |  | 100mV | 4.75 | 5.0 |  | 5.25 |  |\n| 3 | 12V | 0.04A ~ 3.5A | 150mV |  |  | 300mV | 11.4 | 12.0 |  | 12.6 | Note 3 |\n| 4 | +16V | 0.04A ~ 1.33A | 160mV |  |  | 320mV | 15.2 | 16.0 |  | 16.8 | Note 1 |\n| 5 | -16V | 0.04A ~ 1.33A | 160mV |  |  | 320mV | -15.2 | -16.0 |  | -16.8 | Note 1 |\n| 6 | 24V | 0.01A ~ 9A | 300mV |  |  | 600mV | 22.8 | 24.0 |  | 25.2 |  |\n| c. PWR-ON signal is H ( surge power ) |  |  |  |  |  |  |  |  |  |  |  |\n| 1 | +16V | 2A | 360mV |  |  | 720mV | 15.2 | 16.0 |  | 16.8 | Note 1 , 2 |\n| 2 | -16V | 2A | 360mV |  |  | 720mV | -15.2 | -16.0 |  | -16.8 | Note 1 , 2 |\n| Note 1 : +16V / -16V load regulations are the same at any moment.\u003Cbr>Note 2 : Peak current is defined by 200mS @ 0.1Hz.\u003Cbr>Note 3 : 12V load regulation is guaranteed less than +/-10% of rated output voltage . ( combine with 24V )\u003Cbr>Note 4 : Output voltage ripple and noise:\u003Cbr>0.1uF Ceramic Cap. and 35V/10uF Aluminum Cap. Paralleled between the end of output cable, BW=20M Hz . |  |  |  |  |  |  |  |  |  |  |  |\n| 2.2 5Vs Turn-On Delay Time: |  |  |  | Applied the AC input voltage is 100Vacand output load is Full load, output voltage shall remain regulation. |  |  |  |  | ≤ 1Sec. |  |  |\n| 2.3 Power ON/OFF signal ( PWR-ON : CN704 pin 6 ) |  |  |  | Power ON/OFF signal is L (\u003C0.7V) Power ON/OFF signal is H (3.3V) |  |  |  |  | Only 5Vsb output\u003Cbr>5Vsb , 5V , 16V , -16V , 12V , 24V output |  |  |\n| 2.4 Dynamic Load Limitation: |  |  |","cbCaisPSfdp5FhpW","https://ap.wps.com/l/cbCaisPSfdp5FhpW","pdf",60015,"English","# Electrical Requirements\n## Input Characteristics\n## Output Characteristics\n## Protection Characteristics\n## Environmental Characteristics","[{\"question\":\"What are the input voltage and frequency ranges for FSP320-6F01?\",\"answer\":\"The rated input voltage is 100V/240V. The continuous input voltage range is 90VAC to 264VAC, with an input frequency range of 47Hz to 63Hz.\"},{\"question\":\"What efficiency and inrush current requirements apply?\",\"answer\":\"Efficiency must be at least 82% at 100Vac full load and at least 86% at 240Vac full load. Inrush current at cold start (25°C) is specified as less than 100A.\"},{\"question\":\"How does the power supply protect against faults?\",\"answer\":\"It provides over-current protection with shutdown and latch mode behavior, over-power protection with shutdown and auto recovery, and short-circuit protection that triggers shutdown with auto recovery for 5Vsb/5V and latch mode for 12V/16V/-16V/24V.\"}]","FSP320-6F01 - Electrical Specification - 320W AC Power Supply | PDF",1791804255,18]