[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-203133-105":59,"doc-detail-203133-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","frm-1-relay-control-module-installation-and-maintenance-instructions","FRM-1 Relay Control Module - Installation and Maintenance Instructions","","Installation and maintenance instructions for the Notifier FRM-1 Relay Control Module, including key specifications for voltage, current consumption, operating temperature, humidity range, and physical dimensions. The guide explains intended use in intelligent two-wire systems with built-in rotary switch addressing, plus compatibility requirements with listed Notifier control panels. It covers pre-installation precautions, mounting to 4-inch square boxes, compliant wiring practices with control-module barriers, LED indication, relay contact ratings, and verification steps before connecting controlled circuits.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/frm-1-relay-control-module-installation-and-maintenance-instructions/203133/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/frm-1-relay-control-module-installation-and-maintenance-instructions/203133.png","ImageObject",300,407,{"name":92,"@type":93},"Ava Thompson","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-07","2026-09-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",16,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What operating voltage and current does the FRM-1 module support?","Question",{"text":113,"@type":114},"Normal operating voltage is 15 to 32 VDC. Maximum current draw is 6.5 mA with the LED on, and the average operating current is 270 µA with the LED flashing.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What system compatibility is required for proper operation?",{"text":118,"@type":114},"The FRM-1 must be connected to a compatible Notifier system control panel, which is listed by Notifier for compatibility. The module’s addresses are selected via built-in rotary switches.",{"name":120,"@type":111,"acceptedAnswer":121},"Is the module designed to supervise the controlled circuits?",{"text":122,"@type":114},"No. The document states that the module does not supervise controlled circuits, so wiring and circuit connection must follow the provided guidance and appropriate diagrams.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},203133,1788555941,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":130,"read_time":24},1649267921044,"https://us-avatar.wpscdn.com/avatar/1800007509477c92dfb?_k=1786009248482753345","INSTALLATION AND MAINTENANCE INSTRUCTIONS  \nFRM-1 Relay Control Module  \n12 Clintonville Rd Northford, CT 06472-1653  \n(203) 484-7161  \nSpecifications  \nNormal Operating Voltage: 15 to 32 VDC  \nMaximum Current Draw: 6.5 mA (LED on)  \nAverage Operating Current: 270µA (LED flashing)  \nEOL Resistance: Not used  \nTemperature Range: 32˚F to 120˚F (0˚C to 49˚C)  \nHumidity: 10% to 93% Noncondensing  \nDimensions: 41/2″ H x 4″ W x 11/4″ D (Mounts to a 4″ square by 21/8″ deep box.)  \nAccessories: SMB500 Electrical Box; CB500 Barrier  \nBefore Installing  \nThis information is included as a quick reference installation guide. Refer to the appropriate Notifier control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. Disconnect power to the control panel before installing the modules.  \nNOTICE: This manual should be left with the owner/user of this equipment.  \nGeneral Description  \nThe FRM-1 Relay Control Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built-in rotary switches. It allows a compatible control panel to switch discrete contacts by code command. Therelay contains two isolated sets of Form-C contacts, which operate as a DPDT switch and are rated in accordance with the table in the manual. Circuit connections to the relay contacts are not supervised by the module. The module also has a panel controlled LED indicator. This module can be used to replace a CMX-2 module that has been configured for Form-C operation.  \nCompatibility Requirements  \nTo ensure proper operation, this module shall be connected to a compatible Notifier system control panel (list available from Notifier) .  \nMounting  \nThe FRM-1 mounts directly to 4″ square electrical boxes (see Figure 2A) . The box must have a minimum depth of 21 /8″. Surface mounted electrical boxes (SMB500) are available from Notifier.  \nWiring  \nNOTE: All wiring must conform to applicable local codes, ordinances, and regulations. When using control modules in nonpower limited applications, the CB500 Module Barrier must be used to meet UL requirements for the separation of power-limited and nonpower-limited terminalsand wiring. The barrier must be inserted into a 4″x4″x21 /8″ junction box, and the control module must be placed into the barrier and attached to the junction box (Figure 2A) . The power-limited wiring must be placed into the isolated quadrant of the module barrier (Figure 2B) .  \n1. Install module wiring in accordance with the job drawings and  \nappropriate wiring diagrams.  \n2. Set the address on the module per job drawings.  \nNote: Some panels support extended addressing. In order to set the module above address 99 on compatible systems, carefully remove the stop on the upper rotary switch with thumb in the direction shown in Figure 1.  \n3. Secure module to electrical box (supplied by installer), as shown in Figure 2A.  \nFigure 1. Removing rotary switch stop:  \nA78-2318-07  \nFigure 2A. Module mounting with barrier:  \nN500-47-00 1 I56-1170-04  \nRelay Contact Ratings:  \n\n| CURRENT RATING | MAXIMUM VOLTAGE | LOAD DESCRIPTION | APPLICATION |\n| --- | --- | --- | --- |\n| 3 A | 30 VDC | Resistive | Non Coded |\n| 2 A | 30 VDC | Resistive | Coded |\n| .9 A | 110 VDC | Resistive | Non Coded |\n| .9 A | 125 VAC | Resistive | Non Coded |\n| .5 A | 30 VDC | Inductive (L/R=5ms) | Coded |\n| 1 A | 30 VDC | Inductive (L/R=2ms) | Coded |\n| .5 A | 125 VAC | Inductive (PF= .35) | Non Coded |\n| .7 A | 75 VAC | Inductive (PF= .35) | Non Coded |\n\nAll relay switch contacts are shipped as shown in Figure 3, but may have transferred during shipping. To ensure that the switch contacts are in their correct state, modules must be made to communicate with the panel before connecting circuits controlled by the module.  \nFigure 3. Relay module wiring diagram:  \nCOM","cbCaii6jri4bAPY4","https://ap.wps.com/l/cbCaii6jri4bAPY4","pdf",335734,"English","# Specifications\n## Before Installing\n## General Description\n## Compatibility Requirements\n## Mounting\n## Wiring\n## Relay Contact Ratings","[{\"question\":\"What operating voltage and current does the FRM-1 module support?\",\"answer\":\"Normal operating voltage is 15 to 32 VDC. Maximum current draw is 6.5 mA with the LED on, and the average operating current is 270 µA with the LED flashing.\"},{\"question\":\"What system compatibility is required for proper operation?\",\"answer\":\"The FRM-1 must be connected to a compatible Notifier system control panel, which is listed by Notifier for compatibility. The module’s addresses are selected via built-in rotary switches.\"},{\"question\":\"Is the module designed to supervise the controlled circuits?\",\"answer\":\"No. The document states that the module does not supervise controlled circuits, so wiring and circuit connection must follow the provided guidance and appropriate diagrams.\"}]","FRM-1 Relay Control Module - Installation and Maintenance Instructions | PDF"]