[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-203132-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-203132-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","frm-1-relay-control-module-installation-and-maintenance-instructions","FRM-1 Relay Control Module - Installation and Maintenance Instructions","","Installation and maintenance instructions for the FRM-1 Relay Control Module, detailing specifications, operating electrical limits, environmental conditions, and physical dimensions. The guide explains how the module functions in intelligent two-wire systems using built-in rotary switches for individual addressing and how it switches discrete contacts via Form-C relay contacts. It covers compatibility with specific Notifier control panels, mounting options, wiring and address setup steps, relay contact ratings, and commissioning/communication requirements before connecting controlled circuits.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/frm-1-relay-control-module-installation-and-maintenance-instructions/203132/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/frm-1-relay-control-module-installation-and-maintenance-instructions/203132.png","ImageObject",300,407,{"name":42,"@type":43},"Lucas Martin","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-08","2026-09-04",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the FRM-1 Relay Control Module intended to do?","Question",{"text":63,"@type":64},"It switches discrete contacts by code command in compatible intelligent, two-wire systems using built-in rotary switches for per-module addressing. The relay provides two isolated Form-C contact sets for DPDT switching.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which control panels are compatible with the FRM-1 module?",{"text":68,"@type":64},"The module must connect to a compatible Notifier system control panel. The compatible control panel list is provided by Notifier in the manual context.",{"name":70,"@type":61,"acceptedAnswer":71},"Do wiring methods require a barrier in some installations?",{"text":72,"@type":64},"Yes. When control modules are used in nonpower limited applications, the CB500 Module Barrier is required to separate power-limited and nonpower-limited terminals and wiring to meet UL requirements.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},203132,1790126315,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":97},8796095360427,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","InstallatIon anD MaIntenanCe InstRuCtIons  \nI 56-3502-002  \nFRM-1 Relay Control Module  \n12 Clintonville Road Northford, CT 06472-1653 Phone: 203.484.7161  \nspeCIFICatIons  \nNormal Operating Voltage: 15 to 32 VDC  \nMaximum Current Draw: 6.5 mA (LED on)  \nAverage Operating Current: 230µA direct poll; 255µA group poll  \nEOL Resistance: Not used  \nTemperature Range: 32˚F to 120˚F (0˚C to 49˚C)  \nHumidity: 10% to 93% Non-condensing  \nDimensions: 41/2˝ H x 4˝ W x 11/4˝ D (Mounts to a 4˝ square by 21/8˝ deep box.)  \nAccessories: SMB500 Electrical Box; CB500 Barrier  \n\n| BeFoRe InstallIng\u003Cbr>This information is included as a quick reference installation guide. Refer to the appropriate Notifier control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. Disconnect power to the control panel before installing the modules.\u003Cbr>NOTICE: This manual should be left with the owner/user of this equipment.\u003Cbr>geneRal DesCRIptIon\u003Cbr>The FRM-1 Relay Control Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built-in rotary switches. It allows a compatible control panel to switch discrete contacts by code command. The relay contains two isolated sets of Form-C contacts, which operate as a DPDT switch and are rated in accordance with the table in the manual. Circuit connections to the relay contacts are not supervised by the module. The module also has a panel controlled LED indicator. This module can be used to replace a CMX-2 module that has been configured for Form-C operation.\u003Cbr>CoMpatIBIlIty RequIReMents\u003Cbr>To ensure proper operation, this module shall be connected to a compatible Notifier system control panel (list available from Notifier) .\u003Cbr>FIguRe 1. ContRols anD InDICatoRs:\u003Cbr>C1071-00\u003Cbr>MountIng\u003Cbr>The FRM-1 mounts directly to 4-inch square electrical boxes (see Figure 2A) . The box must have a minimum depth of 21/8 inches. Surface mounted electrical boxes (SMB500) are available from Notifier. The module can also mount to the DNR(W) duct housing. | FIguRe 2a. MoDule MountIng FIguRe 2B: wIth BaRRIeR: |  |\n| --- | --- | --- |\n|  | | |\n|  | C1070-00\u003Cbr>wIRIng\u003Cbr>NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. When using control modules in nonpower limited applications, the CB500 Module Barrier must be used to meet UL requirements for the separation of power-limited and nonpower-limited terminals and wiring. The barrier must be inserted into a 4˝ × 4˝ × 21/8˝ junction box, and the control module must be placed into the barrier and attached to the junction box (Figure 2A) . The power-limited wiring must be placed into the isolated quadrant of the module barrier (Figure 2B) .\u003Cbr>1. Install module wiring in accordance with the job drawings and appropriate wiring diagrams.\u003Cbr>2. Set the address on the module per job drawings.\u003Cbr>3. Secure module to electrical box (supplied by installer), see Figure 2A. Wire should be stripped to the appropriate length (recommended strip length is 1/4“ to 3/8”) . Exposed conductor should be secured under the clamping plate and should not protrude beyond the terminal block area. Caution: Do not loop wire under terminals. Break wire run to provide supervision of connections. |  |\n\nNO-460-006 1 I56-3502-002  \nRelay ContaCt RatIngs:  \n\n| CURRENT RATING | MAXIMUM VOLTAGE | LOAD DESCRIPTION | APPLICATION |\n| --- | --- | --- | --- |\n| 3 A | 30 VDC | Resistive | Non-coded |\n| 2 A | 30 VDC | Resistive | Coded |\n| .9 A | 110 VDC | Resistive | Non-coded |\n| .9 A | 125 VDC | Resistive | Non-coded |\n| .5 A | 30 VDC | Inductive (L/R=5ms) | Coded |\n| 1 A | 30 VDC | Inductive (L/R=2ms) | Coded |\n| .3 A | 125 VAC | Inductive (PF= .35) | Non-coded |\n| 1.5 A | 25 VAC | Inductive (PF = .35) | Non-coded |\n| .7 A | 70.7 VAC | Inductive (PF= .35) | Non-coded","cbCaipPedTf54AXp","https://ap.wps.com/l/cbCaipPedTf54AXp","pdf",945238,"English","# Before Installing\n# General Description\n# Compatibility Requirements\n# Mounting\n# Wiring\n# Relay Contact Ratings\n# Warning","[{\"question\":\"What is the FRM-1 Relay Control Module intended to do?\",\"answer\":\"It switches discrete contacts by code command in compatible intelligent, two-wire systems using built-in rotary switches for per-module addressing. The relay provides two isolated Form-C contact sets for DPDT switching.\"},{\"question\":\"Which control panels are compatible with the FRM-1 module?\",\"answer\":\"The module must connect to a compatible Notifier system control panel. The compatible control panel list is provided by Notifier in the manual context.\"},{\"question\":\"Do wiring methods require a barrier in some installations?\",\"answer\":\"Yes. When control modules are used in nonpower limited applications, the CB500 Module Barrier is required to separate power-limited and nonpower-limited terminals and wiring to meet UL requirements.\"}]","FRM-1 Relay Control Module - Installation and Maintenance Instructions | PDF",1788555940]