[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-467113-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-467113-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","fracture-resistance-of-commercial-and-novel-ceramic-reinforced-polymer-crowns-with-luting-cements-of-varying-elastic-modulus-in-vitro-study","Fracture Resistance of Commercial and Novel Ceramic-Reinforced Polymer Crowns with Luting Cements of Varying Elastic Modulus - in vitro study","","This in vitro study investigated the fracture resistance of three ceramic-reinforced polymer (CRP) crowns—Cerasmart 270, VarseoSmile Crown Plus, and the newly developed Hassawat-01—luted with cements of different elastic moduli. The principal hypothesis stated that neither CRP type nor cement modulus would significantly affect fracture resistance. Ninety-nine mandibular first molar resin dies received 1 mm thick crowns (n=33 each) and were luted with Maxcem Elite, RelyX Unicem, or Ketac Cem (n=11 per subgroup). Occlusal cement morphology was assessed by Micro-CT and fracture resistance by universal testing machine, showing >2000 N for Maxcem or RelyX groups.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/fracture-resistance-of-commercial-and-novel-ceramic-reinforced-polymer-crowns-with-luting-cements-of-varying-elastic-modulus-in-vitro-study/467113/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/fracture-resistance-of-commercial-and-novel-ceramic-reinforced-polymer-crowns-with-luting-cements-of-varying-elastic-modulus-in-vitro-study/467113.png","ImageObject",300,407,{"name":42,"@type":43},"Guten tag","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-31","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What was the main hypothesis of the study?","Question",{"text":63,"@type":64},"The study hypothesized that neither the CRP crown type nor the elastic modulus of the luting cement would significantly affect fracture resistance.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were fracture resistance and cement morphology evaluated?",{"text":68,"@type":64},"Occlusal cement morphology was evaluated using Micro-CT, and fracture resistance was measured with a universal testing machine.",{"name":70,"@type":61,"acceptedAnswer":71},"Which luting cements produced the strongest fracture resistance?",{"text":72,"@type":64},"Crowns luted with Maxcem or RelyX withstood forces greater than 2000 N without visible failure.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},467113,1790887475,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},687212321768,"https://ap-avatar.wpscdn.com/avatar/a0010bdbe886d2fe77?x-image-process=image/resize,m_fixed,w_180,h_180&k=1789897067658708522","Article  \nFracture Resistance of Commercial and Novel  \nCeramic-Reinforced Polymer Crowns with Luting Cements of Varying Elastic Modulus  \nNaluemol Sriprasert 1,2, Nantawan Krajangta 1, Thanakorn Wasanapiarnpong 3, Pavinee Padipatvuthikul Didron 4 and Thanasak Rakmanee 1, *  \nAcademic Editor: Sufyan Garoushi  \nReceived: 4 November 2025  \nRevised: 15 December 2025  \nAccepted: 18 December 2025  \nPublished: 22 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Department of Restorative and Esthetic Dentistry, Faculty of Dentistry, Thammasat University, Patum Thani 12120, Thailand; [naluemol.s@rsu.ac.th](naluemol.s@rsu.ac.th) (N.S.); [knantawa@tu.ac.th](knantawa@tu.ac.th) (N.K.)  \n2 College of Dental Medicine, Rangsit University, Patum Thani 12120, Thailand  \n3 Upcycled Materials from Industrial and Agricultural Wastes Research Unit, Department of Materials Science, Faculty of Science, Chulalongkorn University, Bangkok 10110, Thailand; thanakorn.w@chula.ac.th  \n4 Department of General Dentistry, Faculty of Dentistry, Srinakharinwirot University, Bangkok 10110, Thailand; [pavinee.didron@gmail.com](pavinee.didron@gmail.com)  \n* Correspondence: [rthanasa@tu.ac.th](rthanasa@tu.ac.th); Tel.: +66-2-986-9205  \nAbstract  \nThis in vitro study investigated the fracture resistance of three ceramic-reinforced polymer (CRP) crowns—Cerasmart® 270 (CE; milled), VarseoSmile Crown Plus® (VS; 3D-printed) and the newly developed Hassawat-01 (HS; 3D-printed)—luted with cements of different elastic moduli. The principal hypothesis was that neither the CRP type nor the modulus of cement would significantly affect fracture resistance. Ninety-nine mandibular first molar resin dies were restored with 1 mm thick CE, VS, or HS crowns (n = 33 each) and luted with Maxcem Elite®, RelyX Unicem®, or Ketac Cem® (n = 11 per subgroup) . Occlusal cement morphology was evaluated using Micro-CT. Fracture resistance was measured using a universal testing machine. Crowns luted with Maxcem or RelyX withstood forces >2000 N without visible failure. Ketac-luted crowns showed reduced fracture resistance. CE-Ketac fractured in 4 of 11 specimens. VS-Ketac exhibited cracks or complete fractures (1795.2 ± 156.7 N), whereas HS-Ketac showed only superficial cracking (1732.6 ± 127.3 N) . CRP crowns luted with lower-modulus resin cements demonstrated superior fracture resistance compared with those luted with glass-ionomer. VS exhibited both cracking and occasional complete fractures, whereas HS exhibited only surface cracking. All materials withstood loads greater than typical masticatory forces, supporting HS as a promising alternative within the CRP.  \nKeywords: ceramic-reinforced polymer; resin nanoceramic; luting cement; fracture resistance; elastic modulus  \n1. Introduction  \nCeramic-reinforced polymers (CRPs) have become an important class of hybrid restorative materials, combining the toughness, reparability, and photopolymerization advantages of cross-linked polymers with the strength, stiffness, and esthetics provided by inorganic ceramic fillers [1–6] . CRPs are typically classified into polymer-infiltrated ceramic networks (PICNs) and resin nanoceramics (RNCs) . PICNs contain a porous silanized ceramic scaffold—usually leucite-or zirconia-based—into which a polymer infiltrates to form an interpenetrating network, whereas RNCs incorporate nanoscale silica or barium-glass  \n(BG) fillers within a highly cross-linked resin matrix [4,5,7] . Among commercial RNCs, Cerasmart® 270 (CE), which contains 71 wt.% ceramic fillers (20 nm silica and 300 nm barium glass), has shown favorable mechanical behavior and clinical performance [5] .  \nAlthough CAD/CAM milling of pre-polymerized CRP blocks provides consistent material quality, it is inherently wasteful and can introduce microcracks during machining. Additive","cbCaia7US9Yx2Jel","https://ap.wps.com/l/cbCaia7US9Yx2Jel","pdf",2300951,18,"English","# Abstract\n# Keywords\n# 1. Introduction","[{\"question\":\"What was the main hypothesis of the study?\",\"answer\":\"The study hypothesized that neither the CRP crown type nor the elastic modulus of the luting cement would significantly affect fracture resistance.\"},{\"question\":\"How were fracture resistance and cement morphology evaluated?\",\"answer\":\"Occlusal cement morphology was evaluated using Micro-CT, and fracture resistance was measured with a universal testing machine.\"},{\"question\":\"Which luting cements produced the strongest fracture resistance?\",\"answer\":\"Crowns luted with Maxcem or RelyX withstood forces greater than 2000 N without visible failure.\"}]","Fracture Resistance of Commercial and Novel Ceramic-Reinforced Polymer Crowns with Luting Cements of Varying Elastic Modulus - in vitro study | PDF",1790772327,45,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5da61d6723f257eeae6812618d915d89.webp",983,1390,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/8b20516fad7618d73e253477eb80dc6c.webp",982,1388,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ce2d4d79ae063739e56dac18c6a505e8.webp",981,1387,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/28685cdd475c0af6f25f3946f083dced.webp",980,1385]