[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662108-105":59,"doc-detail-662108-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","fp715-si-installation-user-instructions","FP715 Si - Installation & User Instructions","","FP715 Si is a 2-channel full programmer for central heating and hot water, with a service interval timer and support for 24V models. The document provides installation guidance, product specifications, and detailed wiring instructions, including DIL switch configuration and installer setting selection for 24hr, 5/2 day, and 7 day modes. It explains preset programme operation, date/time setup, programme acceptance, temporary overrides, holiday programming, clock changes, advanced options, and copy functions (Standard, Enhanced, AB). It also covers resetting, troubleshooting, and contact information.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/fp715-si-installation-user-instructions/662108/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/fp715-si-installation-user-instructions/662108.png","ImageObject",300,407,{"name":92,"@type":93},"Eliana","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who should install the FP715 Si programmer and what standards should be followed?","Question",{"text":112,"@type":113},"The document states the product should only be installed by a qualified electrician or a competent heating installer and must comply with the current edition of the IEEE wiring regulations.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How are the DIL switch settings configured before mounting?",{"text":117,"@type":113},"Before mounting, the four DIL switches on the rear of the plug-on module must be moved to the required settings, and the installer setting option inside the flap label should be ticked to notify the user of the selected mode.",{"name":119,"@type":110,"acceptedAnswer":120},"What do the copy functions do and where are they enabled?",{"text":121,"@type":113},"There are three copy functions: Standard Copy, Enhanced Copy, and AB copy. They are enabled/disabled in Advanced Programming Options, with Standard Copy limited to 5+2 or 7 day modes and Enhanced Copy available in 7 day mode for copying events between days.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662108,1793199704,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},4398048949847,"https://ap-avatar.wpscdn.com/avatar/400002536579ef2da7f?_k=1778318612642679267","FP715 Si  \nElectronic, 2-channel full programmer for heating & hot water with service interval timer  \nInstallation & User Instructions  \n(Including 24V Models)  \n®  \nCertification Mark  \nIndex  \nIndex  \nInstallation Instructions  \nProduct speciﬁcation and Installation 3  \nInstallation and Wiring 4  \nDIL switch settings 5  \nAdvanced Programming Options 5  \nCopy Functions 6-7  \nService Interval Timer 7  \nWiring Conversion 8-15  \nUser Instructions   \nWhat is a Programmer? 16  \nYour programmer 17  \nPreset programmes 17  \nResetting the unit 18  \n24hr or AM/PM display 18  \nSetting the Date, Time and Day 18-19  \nAccepting the preset programmes 19  \nChanging the preset programmes 20  \nProgramming heating-5/2 day 21-22  \nProgramming heating-7 day 23-24  \nProgramming heating-24 hour 25  \nProgramming hot water 26  \nRunning the programme 27  \nTemporary overrides 28  \nHoliday Programme 29  \nChanging clocks forward/back 30  \nService Interval Timer 31  \nFully Resetting the Unit 32  \nTroubleshooting 34  \nContact details 36  \nCentral Heating 1HR override  \nCentral Heating MAN override  \nCentral Heating Mode SELECT  \nHot Water 1HR override  \nHot Water  \nMAN override  \nHot Water Mode SELECT  \nRESET  \nInstallation Instructions  \nPlease Note: This product should only be installed by aqualiﬁed electrician or competent heating installer, and should be in accordance with the current edition of the IEEE wiring regulations.  \nProduct speciﬁcation  \n\n| Speciﬁcation | 230V model | 24V model |\n| --- | --- | --- |\n| Power supply | 230 Vac,±15%, 50/60 Hz | 24 Vac,±15%, 50/60 Hz |\n| Switching action | 2 x SPDT internally linked, Type 1B |  |\n| Unit switch rating | 230 Vac,\u003Cbr>3(1)A | 24Vac,\u003Cbr>3(1)A |\n| Battery back-up | 24 hours minimum |  |\n| Programme resolution | ± 1 minute |  |\n| Dimensions, mm (W, H, D) | 135 x 88 x 32 |  |\n| Design standard | EN 60730-2-7 |  |\n| Control Pollution Situation | Degree 2 |  |\n| Rated Impulse Voltage | 2.5 kV |  |\n| Ball Pressure Test | 75°C |  |\n\nInstallation  \nO Remove wallplate from unit by unscrewing the two screwson the bottom edge of the unit.  \nO From the top left hand corner of the wallplate, there must be clearances of at least 140 mm to the right, 15mm to the left, 30mm above and 100mm below in order to mount the plug-on module.  \nInstallation & Spec iﬁ cation  \nInstallation and Wiring  \nO The wallplate must be securely mounted either directly to the wall using suitable wood screws or to a ﬂush mounted 1-gang electrical accessory box using M3.5 screws.  \nO Cable access can either be from behind for concealed cabling, or from below for surface cabling. If surface cable is used, cut out cable access slot on plug-on module prior to mounting.  \nO For wiring connections refer to diagram below.  \nFP715 Si models are double insulated and do not require an earth connection, however a parking terminal is provided on the wallplate. This is clearly marked with an Earth symbol.  \nO Prior to mounting the plug-on module, DIL switches on the rear of the plug-on module must be set. See diagram on page 5 for available options.  \nO Mount plug-on module to wallplate by locating tabs ontop of wallplate in apertures on rear of module, hinge down and press ﬁrmly to wallplate before tightening securing screws on bottom of wallplate.  \n4  \nWiring (For Wiring Conversion tables see-pages 8-15)  \n| N | L | 1 | 2 | 3 | 4 |\n| --- | --- | --- | --- | --- | --- |\n\nPlease Note:  \nOn 24 volt models power supply must be wired to A & Bon wallplate.  \n230V Fused 3A  \nOFF  \nDHW  \nOFF  \nHTG  \nON  \nDHW  \nON  \nHTG  \nAlways switch o􀀂 mains ﬁrst and never ﬁt programmer to a live wallplate.  \nDIL Switch Settings  \nBefore mounting the unit, ensure the 4 DIL switches on the rear have been moved to the required settings.  \n!  \nTick the INSTALLER SETTING box on the inside ﬂap label to notify user in which mode their unit is set (24hr, 5/2 day or 7 day) .  \nSw.1  \nSw.2  \nSw.3  \nSw.4  \nNot Used Gravity 5/2 Day 7 Day  \n\n|  |  |\n| --- | --- |\n|  |  |\n|  |  |\n|  ","cbCaicraeoNByQND","https://ap.wps.com/l/cbCaicraeoNByQND","pdf",1024966,36,"English","# Installation and Wiring\n## Product specification and installation\n## Installation instructions\n## Wiring and wiring conversion tables\n## DIL switch settings\n## Advanced programming options\n## Copy functions\n## Service interval timer\n# User instructions\n## What is a programmer\n## Preset programmes\n## Resetting the unit\n## 24hr or AM/PM display\n## Setting the date, time and day\n## Accepting preset programmes\n## Changing preset programmes\n## Heating 5/2 day programming\n## Heating 7 day programming\n## Heating 24 hour programming\n## Hot water programming\n## Running the programme\n## Temporary overrides\n## Holiday programme\n## Changing clocks forward/back\n## Fully resetting the unit\n## Troubleshooting\n## Contact details","[{\"question\":\"Who should install the FP715 Si programmer and what standards should be followed?\",\"answer\":\"The document states the product should only be installed by a qualified electrician or a competent heating installer and must comply with the current edition of the IEEE wiring regulations.\"},{\"question\":\"How are the DIL switch settings configured before mounting?\",\"answer\":\"Before mounting, the four DIL switches on the rear of the plug-on module must be moved to the required settings, and the installer setting option inside the flap label should be ticked to notify the user of the selected mode.\"},{\"question\":\"What do the copy functions do and where are they enabled?\",\"answer\":\"There are three copy functions: Standard Copy, Enhanced Copy, and AB copy. They are enabled/disabled in Advanced Programming Options, with Standard Copy limited to 5+2 or 7 day modes and Enhanced Copy available in 7 day mode for copying events between days.\"}]","FP715 Si - Installation & User Instructions | PDF",91]