[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662180-105":59,"doc-detail-662180-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","forward-model-12000lalfiarfour-post-drive-on-lift-installation-and-operators-manual","FORWARD MODEL 12000LA/LFIARFOUR POST DRIVE ON LIFT - INSTALLATION AND OPERATOR'S MANUAL","","Installation and operator guidance for a FORWARD Model 12000LA four-post drive-on lift. Specifies required concrete slab thickness and compressive strength, reinforcement requirements, and mounting pad dimensions. Warns against incorrect installation and improper vehicle lifting, including not raising only one end. Provides instructions for anchor bolts, hydraulic hose or stainless tubing routing, power unit positioning, and safety latch clearance, along with oil leak checks and key electrical and arrangement references.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/forward-model-12000lalfiarfour-post-drive-on-lift-installation-and-operators-manual/662180/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/forward-model-12000lalfiarfour-post-drive-on-lift-installation-and-operators-manual/662180.png","ImageObject",300,407,{"name":92,"@type":93},"Blitz","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What concrete requirements must be met before installing the lift?","Question",{"text":112,"@type":113},"The floor must be at least 4 inches thick with a minimum compressive strength of 3000 PSI and reinforced with steel mesh or bars per commercial practice.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What could happen if the recommended mounting surface is not provided?",{"text":117,"@type":113},"Failure to provide the recommended mounting surface may result in unsatisfactory lift performance, property damage, or personal injury.",{"name":119,"@type":110,"acceptedAnswer":120},"How should hydraulic oil leaks be checked on the power unit and cylinder?",{"text":121,"@type":113},"For the power unit, check tank oil level by removing the bleed screw below the top of the tank; for cylinder seepage, raise the lift until the cylinder bottoms out and hold the run button for one minute to confirm whether seals are leaking.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662180,1793205989,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":46},24464137899374,"https://us-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","# FORWARD MODEL 12000LA/LFIARFOUR POST DRIVE ON LIFT,12000 LB CAPACITYINSTALLATION AND OPERATOR'S MANUAL\n\n6.7.2000  \nIMAN 991002  \nIMPORTANT NOTICE:  \nTHE FLOOR IN WHICH THIS LIFT IS TO BE INSTALLED MUST BE 4 INCH MINIMUM THICKNESSCONCRETE,WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI,AND REINFORCED WITHSTEEL MESH OR BAR PER COMMERCIAL PRACTICE.PADS MUST BE TWO FEET BY TWO FEETBY ONE FOOT THICK,REINFORCED WITH STEELPER COMMERCIAL PRACTICE.  \nFAILURE BY THE PURCHASERTO PROVIDE THE RECOMMENDED MOUNTING SURFACE COULDRESULT IN UNSATISFACTORY LIFT PERFORMANCE,PROPERTY DAMAGE,OR PERSONALINJURY.  \nIMPORTANT:  \nREAD THIS INSTRUCTION MANUAL BEFORE INSTALLING THE LIFT,  \nREAD THE ANCHOR BOLT INSTRUCTION PAGE BEFORE DRILLING AND INSTALLING THECONCRETE ANCHOR BOLTS.  \nDO NOT RAISE A VEHICLE ON THE LIFT UNTIL THE LIFT HAS BEEN CORRECTLY INSTALLED ANDADJUSTED AS DESCRIBED IN THIS MANUAL.  \nREFER TO FIGURE1,GENERAL ARRANGEMENT.THE LIFT IS TO BE INSTALLED WITH THE TOPRAILON THE PASSENGER SIDE AS SHOWN.THE STANDARD MOUNTING POSITIONS FOR THEPOWER UNIT IS ALSO SHOWN.IFIT IS NECESSARY TO MOUNT THE POWER UNIT INANOTHERPOSITION,THE INSTALLER MUST REROUTE THE HYDRAULIC LINES TO THE PUMP.THEINSTALLER MUST USE 3/8 DIAMETER HYDRAULICHOSE OR STAINLESS STEEL TUBING WITHARATED WORKING PRESSURE OF 2500 PSIAND A RECOMMENDED RATED BURST PRESSURE OF6000 PSI.THE ROUTING OF THE HYDRAULICLINES SHOULD CLEARTHE SAFETY LATCHMECHANISM OF THE TOP RAIL。  \nIMPORTANT NOTICE:  \nNEVER USE THIS LIFT TO RAISE JUST ONE END OF ANY VEHICLE.PROPERTY DAMAGE ORPERSONAL INJURY COULD RESULT.  \nPANZITTA SALES &SERVICE72 George AvenueWilkes-Barre,PA 18705570-822-6720  800-822-6720www.panzittasales.com  \nDrive On Ramp-  \nPANZITTA SALES &SERVICE72 George AvenueWilkes-Barre,PA 18705570-822-6720800-822-6720www.panzittasales.comTop Rail On Left Side  \nCrossrailTrack End StopTop Rail On Right Side  \nFigure 1.General Arrangment  \n72 George Avenue  \nFIGURE 10.FENNER POWER UNITWITH(2)HOSE CONNECTIONS.  \nFIGURE 11.WIRING DIAGRAM:FENNER POWER UNIT  \nPANZITTA SALES &SERVICE72 George AvenueWilkes-Barre,PA 18705570-822-6720  800-822-6720www.panzittasales.com  \nFigure 6.120001b.Lift,Crossrail Chain Arrangement  \nFigure 17.Exploded ViewPage 22  \nPANZITTA SALES &SERVICE72 George AvenueWilkes-Barre,PA 18705570-822-6720  800-822-6720www.panzittasales.com  \nC  \n4-POST LIFT  \nEXPLODED VIEW PARTS LIST  \nITEMPART NO.  REV NAME/DESCRIPTION  \n1  \n120101CM/S Leg Weldment2120102CM/S Leg Weldment W/Power Unit Mntg.3120201BO/S Leg Weldment4121300DT/R Assembly5121400CX-Rail Assembly6992028Power Unit,Fenner 1174,4-Post7995210Safty Rod8992169Hose,3/8x45”High Pressure9992103Hose,3/8x106”High Pressure10992612Chain,X-Rail119148051-1/8 Flat Washer12991072BL634 Master Link139117015/16NC Nut149117415/16x1 Hx.Hd.Bolt,Power Unit Mounting159118415/16x1-1/2 Shoulder Bolt,Lifting Chain16912601/₂NC Nut17912605%Flat Washer18912607%₂Lock Washer19912771/₂x1-3/4 NC Hx.Hd.Bolt,Gr.8,T/R Mnt.209136013%NC Nut,Safty Rod219137983%4x4-3/4 Anchor Bolt w/Nut,Washer229144041-14 Nyloc Nut9144061”SAE Flat Washer9148041-1/8 NF Nylon Insert Nut,Chain Anchor Stud  \n2324  \nPANZITTA SALES &SERVICE72 George AvenueWilkes-Barre,PA 18705570-822-6720  800-822-6720www.panzittasales.com  \nRQD.  \n1  \n1  \n2  \n工  \n2  \n1  \n4  \n1  \n1  \n2  \n2  \n2  \n6  \n4  \n2  \n8  \n16  \n8  \n8  \n8  \n16  \n2  \n2  \n2  \nPUSHBUTTON  \nRUN SWITCH  \nFOUR POST AND TWO POST BASE PLATE LIFTS  \nTWO POST LIFTS WITH OVERHEAD SAFETY SWITCH  \nFIGURE 11.FENNER POWER UNIT ELECTRICAL DIAGRAMS  \nFIGURE 12.FENNER POWER UNIT INSTALLATION  \n5.    OIL LEAKS.  \nPower Unit:If the power unit leaks hydraulic oil around the tank mounting flange,check the oil level in the tank.The level should be two inches below the flange ofthe tank.Check by removing the bleed screw just below the top of the tank.  \n2.Cylinder:Some seepage from the rod end of the cylinder is normal.Oil in minutequantities adheres to the rod when the lift is lowered.The oil is removed by therod wiper when the lift is raised.This oil will","cbCaij1VJsnHu7Gx","https://ap.wps.com/l/cbCaij1VJsnHu7Gx","pdf",499652,"English","# IMPORTANT NOTICE\n## Installation requirements for floor and reinforcement\n## Installation and anchoring instructions\n## Hydraulic lines, power unit routing, and safety guidance\n## Oil leak checks\n# FIGURES AND PARTS LIST\n## General arrangement and top rail safety latch\n## Fenner power unit electrical diagrams and installation\n## Exploded view parts list","[{\"question\":\"What concrete requirements must be met before installing the lift?\",\"answer\":\"The floor must be at least 4 inches thick with a minimum compressive strength of 3000 PSI and reinforced with steel mesh or bars per commercial practice.\"},{\"question\":\"What could happen if the recommended mounting surface is not provided?\",\"answer\":\"Failure to provide the recommended mounting surface may result in unsatisfactory lift performance, property damage, or personal injury.\"},{\"question\":\"How should hydraulic oil leaks be checked on the power unit and cylinder?\",\"answer\":\"For the power unit, check tank oil level by removing the bleed screw below the top of the tank; for cylinder seepage, raise the lift until the cylinder bottoms out and hold the run button for one minute to confirm whether seals are leaking.\"}]","FORWARD MODEL 12000LA/LFIARFOUR POST DRIVE ON LIFT - INSTALLATION AND OPERATOR'S MANUAL | PDF"]