[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662177-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662177-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","forward-manufacturing-two-post-asymmetrical-lift-installation-and-owners-manual-models-dp97a-dp97a2-dp10a-dp10a2","FORWARD MANUFACTURING - Two Post Asymmetrical Lift - Installation and Owners Manual - Models DP97A, DP97A2, DP10A, DP10A2","","Installation and owner guidance for Forward Manufacturing two post asymmetrical automotive lifts, models DP97A, DP97A2, DP10A, and DP10A2. Provides mandatory pre-installation and safety instructions, including required concrete thickness and compressive strength, ceiling height requirements for each model, and specified electrical service. Covers safe operation limits such as rated capacities, indoor use and outdoor power unit cover conditions, anchoring bolt installation, and prerequisites before raising vehicles. Includes user responsibility guidance for maintenance, inspection, and restricted service procedures.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/forward-manufacturing-two-post-asymmetrical-lift-installation-and-owners-manual-models-dp97a-dp97a2-dp10a-dp10a2/662177/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/forward-manufacturing-two-post-asymmetrical-lift-installation-and-owners-manual-models-dp97a-dp97a2-dp10a-dp10a2/662177.png","ImageObject",300,407,{"name":42,"@type":43},"Aldword","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What installation requirements must be met for the lift to operate safely?","Question",{"text":62,"@type":63},"The floor must be minimum 4 inch thick concrete with at least 3000 PSI compressive strength and reinforced with steel bar. Ceiling height requirements apply: DP97A/DP10A at least 12'-0\", and DP97A2/DP10A2 at least 14'-0\".","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What electrical service does the lift require?",{"text":67,"@type":63},"The lifts require 230V, 60 Hz, single phase, 20 amp electrical service.",{"name":69,"@type":60,"acceptedAnswer":70},"Who is allowed to perform maintenance and restricted procedures?",{"text":71,"@type":63},"Troubleshooting and maintenance procedures described in the manual can be done by the owner/employer. Restricted procedures (such as cylinder replacement, carriage and safety latch replacement, leg replacement, and overhead structure replacement) should be performed only by trained lift service personnel.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662177,1793205982,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},7,40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},2336478940917,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","# FORWARD MANUFACTURINGTWO POST ASYMMETRICAL LIFTINSTALLATION AND OWNERS MANUALMODELS DP97A,DP97A2,DP10A,DP10A2\n\nMAY 2001  \nI MAN 994322  \n## IMPORTANT INSTRUCTIONS:\n\n1.READ THIS MANUAL THOROUGHLY BEFORE INSTALLING,OPERATING,ORMAINTAINING THIS LIFT.  \n2.READ AND REFER TO OFTEN THE FOLLOWING PUBLICATIONS SUPPLIED WITHTHIS MANUAL:  \n1.“LIFTING IT RIGHT”,ALI SM93-1.  \n2.\"AUTOMOTIVE LIFT SAFETY TIPS\",ALI-ST90.  \n3.\"VEHICLE LIFTING POINTS FOR FRAME ENGAGING LIFTS\",ALI/LP-GUIDE.  \n4.“SAFETY REQUIREMENTS FOR OPERATION,INSPECTION,AND MAINTENANCE”,ANSI/ALI ALOIM-1994.  \n3.     FOLLOWING THE INSTALLATION OF THIS LIFT,THIS MANUAL AND THE FOURPUBLICATIONS LISTED UNDER INSTRUCTION NUMBER 2 ABOVE ARE TO BEDELIVERED TO THE OWNER/USER/EMPLOYER OF THE LIFT.  \n4.THE FLOOR ON WHICH THE LIFT IS TO BE INSTALI ED MUST BF.4 INCHMINIMUM THICKNESS CONCRETE,WITHA MINIMUM COMPRESSIVESTRENGTH OF 3000 PSI,AND REINFORCED WITH STEEL BAR.  \nFAILURE BY THE PURCHASER TO PROVIDE THE RECOMMENDEDMOUNTING SURFACE COULD RESULT IN UNSATISFACTORYLIFTPERFORMANCE,PROPERTY DAMAGE,OR PERSONAL INJURY.  \n5.    THE DP97A AND DP10A ARE OVERHEAD TYPE LIFTS WHICH REQUIRE ACEILING HEIGHT OF AT LEAST 12'-0\".THE DP97A2 AND DP10A2 REQUIRE ACEILING HEIGHT OF AT LEAST 14'-0”.  \n6.   THE LIFTS REQUIRE 230V,60 HZ,SINGLE PHASE,20 AMP AC ELECTRICALSERVICE.  \n7.    THE LIFTS ARE DESIGNED FOR INDOOR USE.LIFTS PLACED OUTDOORSMUST BE FITTED WITH THE POWER UNIT COVER,FORWARD PART NUMBER070170 FOR FENNER POWER UNITS.  \n8.    LIFTS PLACED OUTDOORS SHOULD NOT BE USED UNLESS THE POWERUNIT COVER IS INSTALLED AND CONDITIONS ARE DKY.DONOT OPERATETHE LIFT IF MOISTURE IS PRESENT.  \n9.    READ THE ANCHOR BOLT INSTRUCTION PAGE BEFORE DRILLING ANDINSTALLING THE ANCHOR BOLTS.  \n10.   THIS LIFT REQUIRES A CERTAIN INSTALLATION PROCEDURE TO REDUCETHE AMOUNT OF AIR TRAPPED IN THE CYLINDERS.FAILURE TO FOLLOWTHE PROCEDURE WILL RESULT IN UNSATISFACTORY LIFT PERFORMANCE.  \n11.   DO NOT RAISE A VEHICLE ON THE LIFT UNTIL THE LIFT HAS BEENCORRECTLY INSTALLED AND ADJUSTED AS DESCRIBED IN THIS MANUAL.  \n12.   DO NOT EXCEED THE RATED CAPACITY OF THE LIFT.THE DP97A ANDDP97A2 LIFTS ARE RATED AT 9000 LB CAPACITY.THE DP10A AND DP10A2,LIFTS ARE RATED AT 10,000 LB CAPACITY.  \n13.   FOR INFORMATION ON POSITIONING VEHICLES FORLIFTING,REFER TOTHE FOLLOWING PROVIDED PUBLICATIONS:  \n1.“LIFTING IT RIGHT”,ALI SM93-1.  \n2.“VEHICLE LIFTING POINTS FOR FRAME ENGAGING LIFTS”,ALI/LP-GUIDE.ALSO USEFUL,BUT NOT PROVIDED,IS ANSI/SAE J2184-OCT92,“VEHICLELIFT POINTS FOR SERVICE GARAGE LIFTING”.  \n14..  UNUSUAL VEHICLES,SUCH AS LIMOUSINES,RV’S,AND LONG WHEELBASEVEHICLES,MAY NOT BE SUITABLE FOR LIFTING ON THIS EQUIPMENT.IFNECESSARY,CONSULT WITH THE MANUFACTURER OR THEMANTJFACTURER’S REPRESENTATIVE.  \n15.   DO NOT REMOVE A TRANSMISSION,SUSPENSION ASSEMBLY,OR OTHERHEAVY ITEM FROM THE FRONT OF A FRONT WHEEL DRIVE VEHICLEUNLESS THE VEHICLE IS ADEQUATELY SUPPORTED IN THE REAR.  \n16.   THE TROUBLESHOOTING AND MAINTENANCE PROCEDURES DESCRIBED INTHIS MANUAL CAN BE DONE BY THE LIFT’S OWNER/EMPLOYER.ANYOTHER PROCEDURE SHOULD ONLY BE DONE BY TRAINED LIFT SERVICEPERSONNEL.THESE RESTRICTED PROCEDURES INCLUDE THE  \nFOLLOWING:CYLINDER REPLACEMENT,CARRIAGE AND SAFETY LATCHREPLACEMENT,LEG REPLACEMENT,OVERHEAD STRUCTUREREPLACEMENT.  \n17.   REPLACE WORN OR BROKEN PARTS ONLY WITH GENUINE FORWARDMANUFACTURING COMPANY PARTS OR THEIR EQUIVALENT.  \nSAVE THESE INSTRUCTIONS  \n## IMPORTANT SAFETY INSTRUCTIONS\n\n1.    READ ALL INSTRUCTIONS.  \n2.    CARE MUST BE TAKEN AS BURNS CAN OCCUR FROM TOUCHING HOTPARTS.  \n3.   TO REDUCE THE RISK OF FIRE,DO NOT OPERATE EQUIPMENT IN THEVICINITY OF OPEN CONTAINERS OF FLAMMABLE LIQUIDS(GASOLINE).  \n4.   ADEQUATE VENTILATION SHOULD BE PROVIDED WHEN WORKING ONINIERNAL COMBUSTION ENGINES.  \n5.    KEEP HAIR,LOOSE CLOTHING,FINGERS,AND ALLPARTS OF BODY AWAYFROM MOVING PARTS.  \n6.   TO REDUCE THE RISK OF ELECTRIC SHOCK,DO NOT USE ON WETSURFACES OR EXPOSE TO RAIN.  \n7.    USE ONLY AS DESCRIBED IN THIS MANUAI,USE ONLY MANUFACTURER’SRECOMMENDED AT","cbCaidNVUk99gV4r","https://ap.wps.com/l/cbCaidNVUk99gV4r","pdf",1410581,28,"English","# IMPORTANT INSTRUCTIONS\n## IMPORTANT SAFETY INSTRUCTIONS\n## SAFETY INSTRUCTIONS\n## TWO POST LIFT OPERATION","[{\"question\":\"What installation requirements must be met for the lift to operate safely?\",\"answer\":\"The floor must be minimum 4 inch thick concrete with at least 3000 PSI compressive strength and reinforced with steel bar. Ceiling height requirements apply: DP97A/DP10A at least 12'-0\\\", and DP97A2/DP10A2 at least 14'-0\\\".\"},{\"question\":\"What electrical service does the lift require?\",\"answer\":\"The lifts require 230V, 60 Hz, single phase, 20 amp electrical service.\"},{\"question\":\"Who is allowed to perform maintenance and restricted procedures?\",\"answer\":\"Troubleshooting and maintenance procedures described in the manual can be done by the owner/employer. Restricted procedures (such as cylinder replacement, carriage and safety latch replacement, leg replacement, and overhead structure replacement) should be performed only by trained lift service personnel.\"}]","FORWARD MANUFACTURING - Two Post Asymmetrical Lift - Installation and Owners Manual - Models DP97A, DP97A2, DP10A, DP10A2 | PDF",71]