[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-665093-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-665093-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","fls-canopy-specifications-sheet-gable-canopy","FLS Canopy Specifications Sheet - Gable Canopy","","FLS gable canopy specifications outline single gable bolted frame design, required projection from the building steel line, and a 1:12 roof slope. The sheet defines approved fasteners for specific structural connections, lists frame components with material sizes and galvanized steel designations, and details cover elements including roof sheet steel grade, coatings, trim, flashing, and soffit panels. It also specifies weather-sealing closures and provides an approved color palette for roof sheets and trim.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/fls-canopy-specifications-sheet-gable-canopy/665093/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/fls-canopy-specifications-sheet-gable-canopy/665093.png","ImageObject",300,407,{"name":42,"@type":43},"Miles","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What is the required canopy structure and roof slope for the FLS gable canopy?","Question",{"text":62,"@type":63},"The design must be a single gable bolted frame, with the canopy roof slope set to 1:12.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"How far must the canopy extend from the building steel line?",{"text":67,"@type":63},"The canopy must extend out from the building steel line by 42 inches, where the building steel line is the outside edge of the wall girts.",{"name":69,"@type":60,"acceptedAnswer":70},"Which roof and trim coatings and approved colors are specified?",{"text":71,"@type":63},"Roof sheets and trim must use Kynar 500/Hylar 5000 Fluropon colors, with the document listing multiple approved colors including Ash Gray, Autumn Red, Matte Black, Charcoal, Clay, Evergreen, Ivory, Light Stone, Patrician Bronze, Regal White, Roman Blue, Surrey Beige, and Tudor Brown.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},665093,1793289394,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":30,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":111},13056703019404,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","FLS CANOPY SPECIFICATIONS SHEET  \nCANOPIES DESIGNED AND MANUFACTURED UNDER THE PROTECTION OF PATENT NO. 5,299,395 ISSUED 4/5/1994  \nGENERAL NOTES  \n􀀹 Canopy design shall be single gable bolted frame  \n􀀹 Canopy shall extend out from building steel line 42”. Building steel line is defined as the wall girt’s outside edge.  \n􀀹 Canopy roof slope shall be 1:12  \n􀀹 3/8” 16 UNC Grade 5, NC, plated hex head cap screws with nuts shall be used in the following connections: clip angles to existing building structural framing, vertical frame support channels, vertical frame support channel to horizontal support channel, center plates to framing channels  \n􀀹 Other framing connections shall be ¼” 20 UNC grade  \n8, NC, plated hex head cap screws with nuts  \n􀀹 All material shall be new and free from defects FRAME (Refer to circled numbers on Drawings 5001, 1001)  \n1. Horizontal Channel, 5½”x1¾”x14 GA galvanized steel channel (S‐006‐GV)  \n2. Gable Channel‐5, 4”x1½”x16 GA galvanized steel channel (S‐003‐GV)  \n3. Gable Channel‐10, 4”x1½” x 16 GA galvanized steel channel (S‐004‐GV)  \n4. Connection Plates, (2) 12 GA galvanized steel plates (SC‐016‐GV)  \n5. Vertical Channel, 5½”x1¾”x14 GA galvanized steel channel (S‐001‐GV)  \n6. Connection Clip‐Gable Channel, 1¾”x3¾”x 3½”x14 GA galvanized steel angle (SC‐015‐GV)  \n7. Connection Clip‐Vertical Channel, 3”x1⅞” x4” x12 GA galvanized steel angle (SC‐011‐GV)  \n8. Hat Purlin, 20 GA galvanized steel hat channel (S‐005‐ GV)  \n9. Connection Bracket, 5 ¾” channel bracket 1¾” wide  \n10 GA galvanized steel. (SC‐012‐GV)  \n10. Large Connection Bracket, 5 ¾” channel bracket 3 ½”wide, 10 GA galvanized steel. (SC‐013‐GV)  \n11. Reinforcing Clip, 2¼”x2¼”x1¾”, 10 GA galvanized steel (SC‐014‐GV)  \n12. Large Reinforcing Clip, 2¼”x2¼”x3½”, 10 GA galvanized steel (SC‐017‐GV)  \nCOVER (Refer to circled numbers on Drawings 5002, 10002)  \n13. Roof Sheet, 26 GA, 50,000 PSI minimum yield steel (ASTM A446‐72 Grade D) with G‐90 Zinc Coating (ASTM Galvanized Specification A525) or Aluminum‐ Zinc Alloy coating (ASTM Specification A792) Kynar 500/Hylar 5000 Fluropon factory colored  \n14. Transition Flashing, 26 GA, 50,000 PSI minimum yield steel Kynar 500/Hylar 5000 Fluropon factory colored (T‐036‐00)  \n15. Rake Trim, 26 GA, 50,000 PSI minimum yield steel Kynar 500/Hylar 5000 Fluropon factory colored (T‐ 031‐00)  \n16. Soffit Panels, white basket weave vented, 100% vinyl, lifetime limited warranty from Georgia Pacific (C‐044‐ 00)  \n17. Eave Trim, 26 GA, 50,000 PSI minimum yield steel Kynar 500/Hylar 5000 Fluropon factory colored (T‐ 032‐00) or (T‐033‐00)  \n18. Foam Inside Closure, match configuration of roof panel to provide a weather tight seal at the top of side trim (M‐062‐00)  \n19. Eave Filler, 26 GA, 50,000 PSI minimum yield steel Kynar 500/Hylar 5000 Fluropon factory colored (T‐ 035‐00)  \n20. Peak Plate, 26 GA, 50,000 PSI minimum yield steel Kynar 500/Hylar 5000 Fluropon factory colored (T‐ 034‐00)  \nNOTE:  \nAll roof sheets and trim shall be Kynar 500/Hylar 5000 Fluropon colors. Colors shall be Ash Gray, Autumn Red, Matte Black, Charcoal, Clay, Evergreen, Ivory, Light Stone, Patrician Bronze, Regal White, Roman Blue, Surrey Beige and Tudor Brown.  \nPO Box 1484 Brookfield, WI 53008‐1484 T: [262.784.3390 www.](262.784.3390 www.FLScanopy.com)[FLScanopy](262.784.3390 www.FLScanopy.com)[.com](262.784.3390 www.FLScanopy.com)","cbCaify7E6B9PyUg","https://ap.wps.com/l/cbCaify7E6B9PyUg","pdf",532929,"English","# General Notes\n## Frame Components\n## Cover Components\n## Notes and Color Options","[{\"question\":\"What is the required canopy structure and roof slope for the FLS gable canopy?\",\"answer\":\"The design must be a single gable bolted frame, with the canopy roof slope set to 1:12.\"},{\"question\":\"How far must the canopy extend from the building steel line?\",\"answer\":\"The canopy must extend out from the building steel line by 42 inches, where the building steel line is the outside edge of the wall girts.\"},{\"question\":\"Which roof and trim coatings and approved colors are specified?\",\"answer\":\"Roof sheets and trim must use Kynar 500/Hylar 5000 Fluropon colors, with the document listing multiple approved colors including Ash Gray, Autumn Red, Matte Black, Charcoal, Clay, Evergreen, Ivory, Light Stone, Patrician Bronze, Regal White, Roman Blue, Surrey Beige, and Tudor Brown.\"}]","FLS Canopy Specifications Sheet - Gable Canopy | PDF"]