[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-670559-105":59,"doc-detail-670559-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","flexible-high-pressure-sample-tubing-sample-tubing-datasheet","Flexible High Pressure Sample Tubing - Sample Tubing datasheet","","Flexible High Pressure Sample Tubing datasheet describing non-diffusive tubing engineered for tight seals and fast, repeated quick connections. It outlines available lengths (15’, 10’, and 6’) and recommended use cases with AMI portable gas analyzers, sample pumps, and process sample points. The sheet highlights Kevlar fiber construction to prevent oxygen diffusion for trace O2 measurements, plus fittings designed for leak-tight sealing after thousands of connections. It also provides ratings up to 6,500 psig and standard package contents of tubing and compression quick-test fittings.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/flexible-high-pressure-sample-tubing-sample-tubing-datasheet/670559/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/flexible-high-pressure-sample-tubing-sample-tubing-datasheet/670559.png","ImageObject",300,407,{"name":92,"@type":93},"Adam","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-11-01",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What makes the tubing non-diffusive and why is it important?","Question",{"text":112,"@type":113},"The tubing uses a non-diffusive Kevlar fiber construction, preventing oxygen from diffusing through the tubing. This is critical for measuring trace levels of O2.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What connection method do the fittings use?",{"text":117,"@type":113},"The connection fittings are swaged onto the tubing and use an internal O-ring design for a leak-tight seal. No tools are required; finger strength is sufficient to engage the seal.",{"name":119,"@type":110,"acceptedAnswer":120},"Which tubing lengths are recommended for use with AMI analyzers and pumps?",{"text":121,"@type":113},"15’ length is recommended for connecting an AMI portable gas analyzer to the process sample point. 10’ and 6’ lengths are recommended when using an AMI Portable Analyzer with an AMI Sample Pump, using one length to connect the process point to the pump and a second length to connect the pump to the portable analyzer.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},670559,1793570024,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},1374404737137,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","FLEXIBLE HIGH PRESSURE  \nSAMPLE TUBING  \nNON-DIFFUSIVE TUBING DESIGNED FOR TIGHT SEALS & REPEATED QUICK CONNECTIONS  \n\n| \u003Cbr>AVAILABLE OPTIONS\u003Cbr>\u003Cbr>LENGTH PART NUMBER DESCRIPTION |  |  |\n| --- | --- | --- |\n| 15’ Length | 1TUB06 | 15’ length recommended for connecting AMI’s portable Gas Analyzer to the process sample point |\n| 10’ Length | 1TUB08 | 10’ and 6’ lengths recommended when using an AMI Portable Analyzer with an AMI Sample Pump. One length is used to connect the process point to the pump. A second length is used to connect the Sample Pump to the Portable Analyzer. |\n| 6’ Length | 1TUB13 |  |\n\nEvery Sample Tubing includes 1 length of tube and (2) ¼” compression fittings x male Quick-test.  \n QUALITY CONSTRUCTION  \nAMI’s sample tubing is specially designed for connecting AMI Gas Analyzers and pumps to the source of the gas sample. The non-diffusive Kevlar fiber construction of the tube means that oxygen will not diffuse through the tubing, which is critical when measuring trace levels of O2. The tubing and its fittings are rated for up to  \n6,500 psig, making it well-suited to handle high pressure applications  \n QUICK CONNECTIONS  \nThe sample tubing’s connection fittings are swaged onto the tubing and have an internal O-ring design that provide a leak tight seal even after thousands of connections. No tools are required to connect the fittings to the source and simple finger strength is all that is required to engage the seal.  \n15501 Red Hill Avenue, Suite 100, Tustin, CA 92780 USA  \n[www.amio2.com | Tel:](www.amio2.com | Tel:) 1.714.848.5533 | Email: [sales@amio2.com](sales@amio2.com)  \nsample tubing en 2025.12, Copyright © Advanced Micro Instruments® 2025  \nThis data sheet is a general presentation. It does not provide a warranty or guarantee of any kind.  \nPlease contact us for a description of the warranties and guarantees o ered with our products. Directions for use and safety will be given separately. All information herein is subject to change without notice.","cbCaiuWe5c4jpQ0t","https://ap.wps.com/l/cbCaiuWe5c4jpQ0t","pdf",935350,"English","# Available Options\n## Lengths and Part Numbers\n# Quality Construction\n## Non-diffusive Kevlar Fiber\n# Quick Connections\n## Swaged Fittings and O-ring Seal\n# Technical Rating and Packaging\n## Up to 6,500 psig and Included Fittings","[{\"question\":\"What makes the tubing non-diffusive and why is it important?\",\"answer\":\"The tubing uses a non-diffusive Kevlar fiber construction, preventing oxygen from diffusing through the tubing. This is critical for measuring trace levels of O2.\"},{\"question\":\"What connection method do the fittings use?\",\"answer\":\"The connection fittings are swaged onto the tubing and use an internal O-ring design for a leak-tight seal. No tools are required; finger strength is sufficient to engage the seal.\"},{\"question\":\"Which tubing lengths are recommended for use with AMI analyzers and pumps?\",\"answer\":\"15’ length is recommended for connecting an AMI portable gas analyzer to the process sample point. 10’ and 6’ lengths are recommended when using an AMI Portable Analyzer with an AMI Sample Pump, using one length to connect the process point to the pump and a second length to connect the pump to the portable analyzer.\"}]","Flexible High Pressure Sample Tubing - Sample Tubing datasheet | PDF"]