[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-458488-105":59,"doc-detail-458488-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","flexible-conductive-paper-based-sensors-for-on-skin-electrophysiological-monitoring-and-wearable-applications-research-article","Flexible Conductive Paper-Based Sensors for On-Skin Electrophysiological Monitoring and Wearable Applications - Research Article","","Flexible, skin-conformable electrodes require materials that combine mechanical robustness, environmental stability, high electrical performance, and biocompatibility. A flexible conductive composite film is developed by aqueous blending and filtration, integrating PEDOT:PSS, cellulose nanofibers (CNF), and the ionic liquid EMIM ES. ATR-FTIR and SEM confirm successful component integration and a percolated nanofibrillar structure. Mechanical tests reach 335 MPa tensile strength and 21% strain, with stable electrical and electrochemical performance under humidity/temperature and 100,000 fatigue cycles, enabling irritation-free rodent on-skin electrophysiological recordings.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/flexible-conductive-paper-based-sensors-for-on-skin-electrophysiological-monitoring-and-wearable-applications-research-article/458488/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/flexible-conductive-paper-based-sensors-for-on-skin-electrophysiological-monitoring-and-wearable-applications-research-article/458488.png","ImageObject",300,407,{"name":92,"@type":93},"Chumphorn","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-31","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What components form the flexible conductive paper-based sensor film?","Question",{"text":113,"@type":114},"The hybrid film combines PEDOT:PSS, cellulose nanofibers (CNF), and the ionic liquid EMIM ES, fabricated through an aqueous blending and filtration process.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How is the film’s structure and component integration verified?",{"text":118,"@type":114},"ATR-FTIR confirms integration of all components, while SEM shows a percolated nanofibrillar architecture that supports interfacial adhesion and structural integrity.",{"name":120,"@type":111,"acceptedAnswer":121},"What electrical and mechanical performance does the composite demonstrate?",{"text":122,"@type":114},"Mechanical testing reports tensile strength up to 335 MPa with 21% strain, with electrical stability across 10%–90% humidity and 15–55 °C, and electrochemical performance maintained after 100,000 fatigue cycles.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},458488,1790819628,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},2336475401981,"https://ap-avatar.wpscdn.com/avatar/22000c94efd8d5204d?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786935347598174694","This article is licensed under CC-BY 4.0   \n[www.acsami.org](www.acsami.org)  Research Article   \nFlexible Conductive Paper-Based Sensors for On-Skin Electrophysiological Monitoring and Wearable Applications  \nGeorge Al Boustani, Lukas Bichlmaier, Tetsuhiko F. Teshima, * Oleksandr Berezin, Lennart JK Weiß, Koji Sakai, Kenji Kondo, Lukas Hiendlmeier, Defne T̈uz̈un, Beatrice De Chiara, Marta Nikíc, Gil G Westmeyer, Shigeyoshi Inoue, Markus Becherer, and Bernhard Wolfrum *  \n Cite This: [https://doi.org/10.1021/acsami.5c22432](https://doi.org/10.1021/acsami.5c22432)  \nRead Online  \n\n|  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| ACCESS   | Metrics & More |  |  Article Recommendations |  | *sı Supporting Information |\n\nABSTRACT: Flexible, skin-conformable electrodes require materials that combine mechanical robustness, environmental stability, high electrical performance, and biocompatibility. Here, we present a flexible conductive composite film composed of poly(3,4-ethylenedioxythiophene):po  \nlystyrenesulfonate (PEDOT:PSS), cellulose nanofibers (CNF), and the ionic liquid 1-ethyl-3-methylimidazolium ethyl sulfate (EMIM ES). The composite is fabricated via a simple aqueous blending and filtration process, yielding a free-standing film with a robust fibrous microstructure. ATR-FTIR analysis confirms the successful integration of all components, while SEM imaging reveals a percolated nanofibrillar architecture that enhances interfacial adhesion and structural integrity. Mechanical testing reveals a tensile strength of up to 335 MPa, accompanied by a strain of 21%, attributed to the increasing CNF content. Composite films with low CNF content exhibit excellent electrical stability across humidity levels between 10% and 90% and temperatures of 15 − 55 °C, and maintain electrochemical performance after 100,000 cycles of mechanical fatigue testing. On-skin electrophysiological recordings from a rodent model demonstrate stable signal acquisition without skin irritation, establishing the hybrid films as a promising platform for soft, wearable bioelectronic interfaces. KEYWORDS: cellulose nanofibers (CNF), PEDOT:PSS, ionic liquids, conductive composites, flexible electrodes, wearables  \n■ INTRODUCTION  \nFlexible, skin-conformable electrodes are important for emerging applications in noninvasive medical diagnostics, health monitoring, and human−machine interfaces. 1−6 These technologies require conductive materials that maintain electrical performance under complex mechanical deformations and across varying physiological environments.5,7,8 Although traditional thin-film metal electrodes offer high conductivity, their brittleness and rigidity render them unsuitable for long-term integration.9 To overcome these limitations, conductive polymers, such as poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS), have gained attention due to their intrinsic organic composition, ionic conductivity, and favorable skin-interface properties.9−15  \nHowever, PEDOT:PSS, in its pristine form, remains mechanically brittle, particularly under repeated strain when fabricated as standalone films.16, 17 Strategies to improve its mechanical resilience often involve incorporating secondary components such as dopants (e.g., glycerol, polytetrafluoroethylene) or blending with elastomers, hydrogels, and nanofibers. 18−22 While such approaches can enhance mechanical properties and interface wetting, they often compromise conductivity or result in poor environmental durability, especially under fluctuating humidity and temperature conditions.23  \n© XXXX The Authors. Published by American Chemical Society  \nTo address these challenges, researchers have explored hydrogel-based or porous fibrous composites that embed within the PEDOT:PSS matrices.18,24−28 Such approaches enhance the mechanical characteristics of the film but also affect its electrical properties. One strategy that aims to improve the electrical performance is adding ionic liqui","cbCaidE4z7enE3wv","https://ap.wps.com/l/cbCaidE4z7enE3wv","pdf",13423344,14,"English","# Abstract\n# Introduction\n## Materials and performance requirements\n## Limitations of traditional metal electrodes and pristine PEDOT:PSS\n## Strategies using dopants, elastomers, hydrogels, and nanofibers\n## Role of ionic liquids and remaining design challenges\n# Materials background and reported hybrid systems\n## Cellulose-based hybrid conductive films\n## Stability challenges under humidity and repeated deformation","[{\"question\":\"What components form the flexible conductive paper-based sensor film?\",\"answer\":\"The hybrid film combines PEDOT:PSS, cellulose nanofibers (CNF), and the ionic liquid EMIM ES, fabricated through an aqueous blending and filtration process.\"},{\"question\":\"How is the film’s structure and component integration verified?\",\"answer\":\"ATR-FTIR confirms integration of all components, while SEM shows a percolated nanofibrillar architecture that supports interfacial adhesion and structural integrity.\"},{\"question\":\"What electrical and mechanical performance does the composite demonstrate?\",\"answer\":\"Mechanical testing reports tensile strength up to 335 MPa with 21% strain, with electrical stability across 10%–90% humidity and 15–55 °C, and electrochemical performance maintained after 100,000 fatigue cycles.\"}]","Flexible Conductive Paper-Based Sensors for On-Skin Electrophysiological Monitoring and Wearable Applications - Research Article | PDF",1790753391,35,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/75f282926d34d5177a5ed60f91fc7051.webp",983,1296,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/88ef9b4ffb778cfd4c312dc6f4d490db.webp",982,1295,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/900a1b8282a0cf2f28453b718980f6c2.webp",981,1293,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c40f42134da2c66ce7bc2a9fcb4ba804.webp",980,1292]