[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-503507-105":59,"doc-detail-503507-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","first-characterization-of-a-superconducting-undulator-mockup-with-the-casper-ii-magnetic-measurement-system","FIRST CHARACTERIZATION OF A SUPERCONDUCTING UNDULATOR MOCKUP WITH THE CASPER II MAGNETIC MEASUREMENT SYSTEM","","Superconducting insertion devices achieve higher field strength than permanent-magnet IDs at the same gap and period, making magnetic-field quality a dominant performance factor. While permanent-magnet systems have advanced, superconducting IDs require comparable measurement progress. A cryogen-free CASPER II test facility at ANKA was built for conduction-cooled superconducting coils up to 2 m. The system supports training and magnetic-field quality checks, including local field distribution and first/second field integrals. Results are reported for a superconducting undulator mockup with 20 mm period length.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/first-characterization-of-a-superconducting-undulator-mockup-with-the-casper-ii-magnetic-measurement-system/503507/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/first-characterization-of-a-superconducting-undulator-mockup-with-the-casper-ii-magnetic-measurement-system/503507.png","ImageObject",300,407,{"name":92,"@type":93},"Connor ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-18","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is magnetic-field quality critical for insertion devices?","Question",{"text":112,"@type":113},"The performance of insertion devices depends strongly on magnetic field quality, so accurate characterization is fundamental before installation in synchrotron light sources.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the CASPER II facility used for?",{"text":117,"@type":113},"CASPER II is a cryogen-free horizontal test stand that measures conduction-cooled superconducting coils up to 2 m, enabling training and evaluation of field quality and field integrals.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the setup detect and locate quench events during magnet training?",{"text":121,"@type":113},"The coils include voltage taps that divide winding packages; differential voltage readout with a National Instruments PXI system and a quench detection trigger allows determining the quench location based on voltage differences.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},503507,1791722784,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":39,"preview_page_count":81,"preview_urls":144},687207022233,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Proceedings ofIPAC2015, Richmond, VA, USA WEPMA027  \nFIRST CHARACTERIZATION OF A SUPERCONDUCTING UNDULATOR MOCKUP WITH THE CASPER II MAGNETIC MEASUREMENT SYSTEM  \nS. Gerstl\\#, S. Casalbuoni, N. Glamann, A. Grau, T. Holubek, D. Saez de Jauregui, R. Voutta, ANKA Synchrotron Radiation Facility, Karlsruhe Institute of Technology, Karlsruhe, Germany  \nC. Boffo, T. Gerhard, M. Turenne, W. Walter, Babcock Noell GmbH, Würzburg, Germany  \nAbstract  \nSuperconducting insertion devices (IDs) can reach, for the same gap and period length a higher field strength compared to permanent magnet IDs. Their performance depends strongly on the magnetic field quality. While the magnetic measurements technology of permanent magnet based IDs made significant progress during the last years, for superconducting IDs similar major developments are necessary. As a part of our R&D program for superconducting insertion devices at the ANKA synchrotron radiation facility a measurement setup for conduction cooled superconducting coils with a maximum length of 2 m was built and commissioned. In the CASPER II (Characterization Setup for Phase Error Reduction) facility (see Fig . 1) the magnet coilscan be trained and tested for maximum current and field quality, including the local field distribution as well asthe first and second field integrals. In this paper we shortly describe the CASPER II setup and focus on the capability of this measurement device by presenting the results of a superconducting undulator mockup with a period length of 20mm .  \nINTRODUCTION  \nThe performance of insertion devices (IDs) depends strongly on their magnetic field quality. It is of fundamental importance to characterize magnetic field properties of IDs accurately before installation in synchrotron light sources. While for permanent magnet IDs, commercially measuring systems exists, for the characterization of superconducting IDs they are not available. ANKA and Babcock Noell GmbH are pursuing an R&D program aiming to develop superconducting undulators (SCUs) for third and fourth generation light sources [1] . The SCUs developed and under development with BNG make use of NbTi superconducting wire and are conduction cooled. In order to characterize the magnetic field properties of these conduction cooled SCUs, the CASPER II facility has been developed at ANKA [2, 3] .  \nThe CASPER II facility is a horizontal test stand where up to 2 m long superconducting coils can be measured. The setup is cryogen free. The coils under test are put on an aluminium table in a high vacuum environment and surrounded by a shell-like structure of different temperature shields. Cooling is provided by four 2 stage cryocoolers from Sumitomo with a total cooling power of  \n\\# [stefan.gerstl@kit.edu](stefan.gerstl@kit.edu)  \n7: Accelerator Technology  \nT10-Superconducting Magnets  \n5.5 W. An additional one stage cooler from Oerlikon is connected to the 80 K shield. In total eight 500 A current leads are installed to provide power to the main magnet and its correction coils.  \nFor magnet training two switchable bipolar 1500 A power supplies from Bruker in conjunction with an in  \nFigure 1 : Picture of the CASPER II measurement system. house designed quench detection system (built by the Institute for Data Processing and Electronics at the KIT) and a fast data acquisition system from National Instruments is available.  \nThe local magnetic field perpendicular to the beam axis is measured by using 3 Hall probes, which are placed next to each other on a brass sledge. The Hall probes areplaced at different horizontal positions in order to characterize a good field region of ± 10 mm. The sledge is guided by very precisely machined rails through the magnet and stepwise moved along the beam axis. To determine the position of the sledge a laser interferometer with a submircometer resolution is used. Further details can be found in Ref. [3] .  \nFor assessment of the vertical and horizontal first and second field integr","cbCaimySfQCIT8nZ","https://ap.wps.com/l/cbCaimySfQCIT8nZ","pdf",1018996,"English","# Abstract\n# Introduction\n# Magnet Training","[{\"question\":\"Why is magnetic-field quality critical for insertion devices?\",\"answer\":\"The performance of insertion devices depends strongly on magnetic field quality, so accurate characterization is fundamental before installation in synchrotron light sources.\"},{\"question\":\"What is the CASPER II facility used for?\",\"answer\":\"CASPER II is a cryogen-free horizontal test stand that measures conduction-cooled superconducting coils up to 2 m, enabling training and evaluation of field quality and field integrals.\"},{\"question\":\"How does the setup detect and locate quench events during magnet training?\",\"answer\":\"The coils include voltage taps that divide winding packages; differential voltage readout with a National Instruments PXI system and a quench detection trigger allows determining the quench location based on voltage differences.\"}]","FIRST CHARACTERIZATION OF A SUPERCONDUCTING UNDULATOR MOCKUP WITH THE CASPER II MAGNETIC MEASUREMENT SYSTEM | PDF",1791057254,[145,149,153],{"page_no":8,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/998b8481875995f520c8ee19c511a606.webp",983,1308,{"page_no":14,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b00af29e5aa94e51abcd89f978811f0a.webp",982,1307,{"page_no":81,"url":154,"width":155,"height":156},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/fa26db2e159e290889f7508b15a04a7b.webp",981,1305]