[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650623-105":59,"doc-detail-650623-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","fire-safety-design-codes-standards-followed-hydrant-system","Fire Safety Design - Codes & Standards Followed - Hydrant System","","Fire safety design scope following NFPA and Indian Standard (IS) codes, covering fire extinguisher, sprinkler, standpipe and hose, fire service mains, pump installations, smoke control, and water mist systems. The document focuses on hydrant system deliverables, including hydrant layout details, isometric view, piping and instrumentation diagram layout, bill of quantity, hydraulic calculations, and equipment data sheets. Included drawings and system design notes reference TAC requirements and provide typical arrangements for hydrant and HVW spray systems in an electrical GIS project context.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/fire-safety-design-codes-standards-followed-hydrant-system/650623/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/fire-safety-design-codes-standards-followed-hydrant-system/650623.png","ImageObject",300,407,{"name":92,"@type":93},"Oliver","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Which NFPA codes are referenced in the fire safety design?","Question",{"text":112,"@type":113},"The NFPA list includes NFPA 10, NFPA 13, NFPA 14, NFPA 24, NFPA 20, NFPA 92A, and NFPA 750.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which Indian Standard (IS) codes are referenced for fire systems?",{"text":117,"@type":113},"The IS references include IS: 13039, IS 15683, IS 15105, IS 2189, IS 3844, IS 15519, and IS 15301.",{"name":119,"@type":110,"acceptedAnswer":120},"What deliverables are included for the hydrant system?",{"text":121,"@type":113},"Hydrant layout with all details, isometric view, piping and instrumentation diagram layout, bill of quantity, hydraulic calculations, and a data sheet for equipment used in the hydrant system.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650623,1792834660,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144,"preview_page_count":4},8796095461610,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","*DESIGN FOR SAFETY*  \n**CODES & STANDERD FOLLOWED**  \nWe are prepare drawings layout as per codes.  \n1. NFPA (National Fire Protection Association)  \ni. NFPA 10 (Fire Extinguisher)  \nii. NFPA 13 (Sprinkler System)  \niii. NFPA 14 (Stand pipe & Hose System)  \niv. NFPA 24 (Fire Service mains)  \nv. NFPA 20 (Installation of pumps)  \nvi. NFPA 92A (Smoke control system)  \nvii. NFPA 750 (Water Mist System)  \n2. IS (INDIAN STANDARD)  \ni. IS: 13039 (External Hydrants)  \nii. IS 15683 (Fire Extinguisher)  \niii. IS 15105 (Sprinkler System)  \niv. IS 2189 (Fire Alarm System)  \nv. IS 3844 (Internal hydrant & hose reel)  \nvi. IS 15519 (Water mist System)  \nvii. IS 15301 (Installation Of Pumps)  \n3. Other codes.  \ni. TAC (Tarrif advisory committee)  \nii. NBC (National Building Codes)  \n**FIRE  \n1.  \nHYDRA  \n2.  \nWATER  \n3.  \nFIRE AL  \nFIRE SAFETY DESIGNS**  \nNT  \nSYSTEM  \nMIST  \nSYSTEM  \nARM SYSTEM  \n4. SPRINKLER SYSTEM  \n5. EXTINGUISHERs  \n6. GAS SUPPRESSION SYSTEM  \n7. HOSE R (RISER &  \nEEL SYSTEM DOWN COMER)  \n**HYDRANT SYSTEM**  \nWe are deal with  \n1. Hydrant layout with all details.  \n2.Isometric view of Hydrant Layout.  \n3. Piping and Instrumentation Diagram Layout.  \n4. Prepare Bill of quantity.  \n5. Hydraulic Calculations.  \n6. Provide Data sheet of all equipment used in Hydrant system  \n\\#\\#** Drawings which are made by us attached for your reference **\\#\\#  \n|  | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |  | 13 | 14 | 15 | 16 | 17 |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| A\u003Cbr>B\u003Cbr>C | |  |  |  |  |  | |  | |  |  |  | |  |  |  | |  | A |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | B |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | C |\n| D |  |  |  |  |  |  |  |  |  |  |  |  | |  |  |  |  |  | D |\n|  | \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| E |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | E |\n| F |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | F |\n| G |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | G |\n| H |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | H |\n| I | \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>BILL OF QUANTITY\u003Cbr>\u003Cbr>NO DATE DESIGN\u003Cbr>REVIEW REVISION\u003Cbr>TITLE :-   \u003Cbr>LOA No:- \u003Cbr>PROJECT:-\u003Cbr>\u003Cbr>400/132/33 kV GIS PROJECT AT SECTOR-123, NOIDA\u003Cbr>\u003Cbr>\u003Cbr>CLIENT:-\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>TITLE\u003Cbr>ISOMETRIC YARD PIPING LAYOUT FOR SECTOR-123\u003Cbr>DATE DRAWN DESIGNED DESIGN REVIEW\u003Cbr>9.09.16 NADIM MFK SSADRG. NO.\u003Cbr>UPPTCL-PPTPL-TES-HYD-ISO-02\u003Cbr>SCALE\u003Cbr>NTS\u003Cbr>SHEET SIZE A1\u003Cbr>SHEET NO. REVISION\u003Cbr>2 OF 2 2\u003Cbr>|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | I |\n| J |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | J |\n| K\u003Cbr>L |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | K\u003Cbr>L |\n|  | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |  | 13 | 14 | 15 | 16 | 17 |  |\n\n1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17  \nA  \nB  \nC  \nD  \nE  \nF  \nG  \nH  \nI  \nJ  \nK  \nL  \n100NB 80NB  \nH-18  \n33KV G I S HALL  \nREDUCER 100x80  \nH-17  \n100NB  \n100 MVA,132/33kV TRANSFORMER  \n100NB  \n100NB  \n100NB  \n100NB  \n100NB  \nREDUCER 200x100  \n200NB  \n0NNB N 200NB 200NB  \nH-16  \nH-15  \nH-14  \nH-13  \nH-12  \n132KV G I S HALL  \n200NB  \n200NB  \n80NB  \nH-11  \n250NB  \nH-10  \n250NB 250 NB 250NB  \nH-9  \nH-8  \n250NB 250NB  \n0N NB 100NB 250NB 250NB  \nA  \n200 MVA, 400/132kV TRANSFORMER  \n400KV G IS ROOM  \nH-7  \n80NB  \nB  \nC  \n63 MVAR, 400kV  \nBUS REACTOR  \nH-6  \nH-5  \nREDUCER 250x100  \nREDUCER 250x100  \nH-4  \n250NB  \n250NB  \nCONTROL ROOM  \nH-2  \n80NB  \n100NB  \nH-3  \nNB 0 N 100NB STORE ROOM BUILDING  \nD  \nE  \n250NB  \nF  \nG  \nH-1  \nWATER TANK-1  \nH  \nWATER TANK-2  \nNO DATE  \nDESIGN REVIEW  \nREVISION  \nI  \nTITLE :-  \nDRG No :-  \nLOA No:-  \nPROJECT:-  \n400/132/33 kV GIS PROJECT  \nAT SECTOR-123, NOIDA  \nCLIENT:-  \nJ  \nK  \nTITLE  \nDATE  \n09.09.2016 DRG. NO.  \nDRAWN  \nNADIM  \nDESIGNED  \nMFK  \nDESIGN REVIEW  \nL  \nUPPTCL-PPTPL-TES-SEC-123-P&ID-01  \nSCALE SHEET SIZE SHEET NO. REV","cbCaidez4IAk0Fh9","https://ap.wps.com/l/cbCaidez4IAk0Fh9","pdf",14426939,26,"English","# Codes & Standards Followed\n## NFPA\n## Indian Standard (IS)\n## Other Codes\n# Fire Safety Designs\n## Hydrant System Deliverables\n## Drawings and Typical Arrangements","[{\"question\":\"Which NFPA codes are referenced in the fire safety design?\",\"answer\":\"The NFPA list includes NFPA 10, NFPA 13, NFPA 14, NFPA 24, NFPA 20, NFPA 92A, and NFPA 750.\"},{\"question\":\"Which Indian Standard (IS) codes are referenced for fire systems?\",\"answer\":\"The IS references include IS: 13039, IS 15683, IS 15105, IS 2189, IS 3844, IS 15519, and IS 15301.\"},{\"question\":\"What deliverables are included for the hydrant system?\",\"answer\":\"Hydrant layout with all details, isometric view, piping and instrumentation diagram layout, bill of quantity, hydraulic calculations, and a data sheet for equipment used in the hydrant system.\"}]","Fire Safety Design - Codes & Standards Followed - Hydrant System | PDF",66]