[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-650080-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-650080-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","fire-life-safety-plan-review-submittal-guideline","FIRE & LIFE SAFETY PLAN REVIEW SUBMITTAL GUIDELINE","","Fire & Life Safety Plan Review Submittal Guideline outlines required deliverables for reviewing construction plans, including a title sheet with project information, applicable building/fire codes, and any deferred approvals. It specifies building code analysis content per building, complete site plan sheet requirements for access and hydrants, and mandatory life-safety and exiting plan elements such as egress paths, occupant loads, exit signage, fire barriers, and equipment locations. It further defines required architectural and MEP drawings (floor/ceiling/roof plans, door schedules, details, HVAC, plumbing, and electrical) plus fire and life safety specifications guidance.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/fire-life-safety-plan-review-submittal-guideline/650080/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/fire-life-safety-plan-review-submittal-guideline/650080.png","ImageObject",300,407,{"name":42,"@type":43},"Ezra","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-09","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What must be included on the Fire & Life Safety title sheet?","Question",{"text":62,"@type":63},"Include the project name and address, a description of work and scope, applicable building and fire codes plus all applicable NFPA standards, and notes on any deferred approvals for automatic fire sprinklers or other requested systems.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What is required for the life safety and exiting plan?",{"text":67,"@type":63},"Label rooms with their uses and occupancy classifications, provide floor plans showing exiting paths and travel distances, calculate occupant loads and egress loads at exit doors, and indicate illuminated and tactile exit signs. It must also note fire resistive walls/fire areas and show key fire equipment locations like sprinkler risers, fire department connections, and fire alarm control panels.",{"name":69,"@type":60,"acceptedAnswer":70},"Which sheets and drawing types are expected beyond life safety plans?",{"text":71,"@type":63},"The submittal includes floor plan sheets with rated corridor and fire barrier identification, ceiling and roof plan sheets with rated information, door schedules listing ratings and hardware, referenced details for all rated conditions, and mechanical, plumbing, and electrical drawings covering HVAC, gas piping, and emergency lighting/exit signs within fire resistive construction.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},650080,1792816155,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},7,40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":33,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":123,"preview_page_count":4},1099514068035,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","FIRE & LIFE  \nSAFETY  \nPLAN REVIEW SUBMITTAL  \nGUIDELINE  \nTITLE SHEET-To include but not limited to:  \n• Name & address of project.  \n• Description ofWork and Scope of Project.  \n• Applicable Building and Fire Code and all NFPA Standards applicable to the project.  \n• Note any Deferred Approval for Automatic Fire Sprinklers or other systems requested.  \nBUILDING CODE ANALYSIS- ( for each separate building) To include:  \n• Type of Occupancy, Type of Construction and total allowable square footage.  \n• Allowable area increase calculations for sprinklers and/or frontage (if used) .  \n• Identify whether Separated or Non-Separated use.  \n• Number of Stories/Basements, Total Height in feet.  \n• Note any alternate means of protection/construction with documentation on plan.  \n• Note if building is or is not tobe provided with sprinklers and/or fire alarm system.  \n• Note if project in is a Fire Severity Zone for Wildland Urban Interface requirements (CBC 7A) SITE PLAN SHEET(s) - To include:  \n• A plan of the entire site with all buildings at an appropriate scale.  \n• Indicate the area of work if for remodels or alterations/additions.  \n• Note the name and/or designations for all buildings.  \n• Show any and all property lines, assumed property lines, areas used for frontage.  \n• Show all access roads, fire department connections, fences, gates, and safe dispersal areas.  \n• Show the location ofany existing and/or new fire hydrants with available fire flow.  \n• Identify Fire Department Access and obtain Local Fire Department review of site plan for state projects.  \nLIFE SAFETY & EXITING PLAN- (Required):  \n• Label all rooms as to their use within the building and identify occupancy classifications as appropriate.  \n• Complete floor plan of each floor indicating the exiting path from each room and floor with common path of travel distances and maximum travel distance identified, as required by code to the exits.  \n• Calculated occupant loads for spaces and egress loads at exit doors.  \n• Indicate location of all illuminated exit signs and tactile signs.  \n• Note all fire resistive walls (fire walls, fire barriers, shaft walls, etc.) and fire areas.  \n• Location of fire sprinkler riser, fire department connections, and fire alarm control panels  \n• For new construction, provide location of a room capacity sign ifoccupant load is over 50, place at or near the main exit door from the room. (Title 19, Section 3.30)  \n• Show location of all fire extinguishers by type and size.  \nFLOOR PLAN SHEET(s) -To include:  \n• Floor plan ofevery building within the scope of the work in 1/8\" or 1/4\" scale, show all dimensions  \n• Label all rooms with their name or use, show all door swings and all partition walls.  \n• Separately identify all rated corridor walls, fire walls and smoke barriers.  \n• Show section through rated corridor indicating how one-hour protection is maintained for each condition.  \n• Provide appropriate references to rated construction and/or conditions. Where rated conditions are allowed to be exempted, provide note with appropriate code section.  \n• Identify kitchen hoods as Type I or Type II (per mechanical code) CEILING PLAN SHEET(s) - To include:  \n􀁸 Type of ceiling provided.  \n􀁸 Reference to appropriate detail for rated ceilings  \n􀁸 Location of all light fixtures in ceilings.  \nROOF PLAN SHEET-To include:  \n􀁸 Note the roof classification in accordance with CBC Chapter 15, with listed assembly numbers.  \n􀁸 Note slope of roof(s) .  \n􀁸 Note all draft stops (if required)  \nDOOR SCHEDULE(s) -Provided on plans and to include:  \n􀁸 Door identification  \n􀁸 Required rating of door and frame  \n􀁸 Required Panic Hardware noted  \n􀁸 Door Size  \n􀁸 Hardware Group  \n􀁸 Building identification in which it is located DETAILS-To include:  \n􀁸 Details for all rated conditions, appropriately referenced with an assembly/ design number or identification for specific rated condition. Sample of conditions as follows:  \n􀁸 Fire Partition, Fire Wall, Fire B","cbCainjSAjCzW4zn","https://ap.wps.com/l/cbCainjSAjCzW4zn","pdf",52955,"English","# Title Sheet\n# Building Code Analysis\n# Site Plan Sheet(s)\n# Life Safety & Exiting Plan\n# Floor Plan Sheet(s)\n# Ceiling Plan Sheet(s)\n# Roof Plan Sheet\n# Door Schedule(s)\n# Details\n# Mechanical Drawing(s)\n# Plumbing Drawing(s)\n# Electrical Drawing(s)\n# Fire & Life Safety Specifications","[{\"question\":\"What must be included on the Fire \\u0026 Life Safety title sheet?\",\"answer\":\"Include the project name and address, a description of work and scope, applicable building and fire codes plus all applicable NFPA standards, and notes on any deferred approvals for automatic fire sprinklers or other requested systems.\"},{\"question\":\"What is required for the life safety and exiting plan?\",\"answer\":\"Label rooms with their uses and occupancy classifications, provide floor plans showing exiting paths and travel distances, calculate occupant loads and egress loads at exit doors, and indicate illuminated and tactile exit signs. It must also note fire resistive walls/fire areas and show key fire equipment locations like sprinkler risers, fire department connections, and fire alarm control panels.\"},{\"question\":\"Which sheets and drawing types are expected beyond life safety plans?\",\"answer\":\"The submittal includes floor plan sheets with rated corridor and fire barrier identification, ceiling and roof plan sheets with rated information, door schedules listing ratings and hardware, referenced details for all rated conditions, and mechanical, plumbing, and electrical drawings covering HVAC, gas piping, and emergency lighting/exit signs within fire resistive construction.\"}]","FIRE & LIFE SAFETY PLAN REVIEW SUBMITTAL GUIDELINE | PDF"]