[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664118-105":59,"doc-detail-664118-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","fire-detection-and-alarm-section-28-4600-part-1-general","FIRE DETECTION AND ALARM - SECTION 28 4600 - PART 1 GENERAL","","Fire Detection and Alarm covers requirements for designing and installing fire alarm systems, including all components, wiring, conduit, and associated transmitter interfaces to a supervising station. It specifies replacement and removal of existing system elements when indicated, and defines related work across door releases, door hardware monitoring, sprinkler system supervisory and alarm devices, clean-agent releasing and alarm devices, and smoke-damper control. Submittals include NFPA 72 records, manufacturer data, CAD drawings, designer and installer qualifications, inspection and test reports, and operating and maintenance information updated until accepted.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/fire-detection-and-alarm-section-28-4600-part-1-general/664118/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/fire-detection-and-alarm-section-28-4600-part-1-general/664118.png","ImageObject",300,407,{"name":92,"@type":93},"EvelynWrites","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"本节主要涵盖哪些内容？","Question",{"text":112,"@type":113},"本节规定火灾报警系统的设计与安装要求，包括所有组件、布线与管线/导管，并涵盖与监控站通信的发射器、受保护场所到监控站的回路，以及指定的现有系统组件拆除与替换。","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"需要满足哪些相关章节要求？",{"text":117,"@type":113},"需要与多项相关系统协同，包括防火卷帘门释放要求、门五金中电控锁与门阻器由火警系统监测与释放、喷淋系统的监视/报警与执行装置、清洁剂灭火系统的监视/报警与释放装置，以及风管部件中的烟气防火阀由火警系统监测与控制。",{"name":119,"@type":110,"acceptedAnswer":120},"本节对图纸与送审资料有什么要求？",{"text":121,"@type":113},"送审要求包括按NFPA 72填写的Record of Completion、各控制单元与通知/触发设备的制造商详细资料、设计文件用于计划审查与许可的内容（如平面图、竖向图、运行描述与输入/输出矩阵示例等），以及检查与测试计划与报告、运行与维护资料等；图纸需采用CAD .dwg格式。","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664118,1793240097,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},687212989558,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","SECTION 28 4600  \nFIRE DETECTION AND ALARM  \nPART 1 GENERAL  \n1.01 SECTION INCLUDES  \nA. Fire alarm system design and installation, including all components, wiring, and conduit.  \nB. Transmitters for communication with supervising station.  \nC. Circuits from protected premises to supervising station, including conduit.  \nD. Replacement and removal of existing fire alarm system components, wiring, and conduit indicated.  \n1.02 RELATED REQUIREMENTS  \nA. Section 08 3323-Overhead Coiling Doors: Coiling fire doors to be released by fire alarm system.  \nB. Section 08 7100-Door Hardware: Electrically operated locks and door holder devices to be monitored and released by fire alarm system.  \nC. Section 21 1300-Fire-Suppression Sprinkler Systems: Supervisory, alarm, and actuating devices installed in sprinkler system.  \nD. Section 21 2200-Clean-Agent Fire-Extinguishing System: Supervisory, alarm, and releasing devices installed in extinguishing system.  \nE. Section 23 3300-Air Duct Accessories: Smoke dampers monitored and controlled by fire alarm system.  \n1.03 REFERENCE STANDARDS  \nA. 36 CFR 1191-Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines; current edition.  \nB. ADA Standards-Americans with Disabilities Act (ADA) Standards for Accessible Design; 2010.  \nC. IEEE C62 .41.2-Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and less) AC Power Circuits; 2002 (Cor 1, 2012) .  \nD. NFPA 70-National Electrical Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.  \nE. NFPA 72-National Fire Alarm and Signaling Code; 2016.  \nF. NFPA 101-Life Safety Code; 2015.  \n1.04 SUBMITTALS  \nA. See Section 01 3000-Administrative Requirements, for submittal procedures.  \nB. Proposal Documents: Submit the following with cost/time proposal:  \n1. NFPA 72 \"Record of Completion\", filled out to the extent known at the time.  \n2. Manufacturer's detailed data sheet for each control unit, initiating device, and notification appliance.  \n3. Certification by Construction Manager that the system design will comply with Contract Documents.  \n4. Proposed maintenance contract.  \nC. Drawings must be prepared In CAD .dwg format.  \nD. Evidence of designer qualifications.  \nE. Design Documents: Submit all information required for plan review and permitting by authorities having jurisdiction, including but not limited to floor plans, riser diagrams, and description of operation:  \n1. Copy (if any) of list of data required by authority having jurisdiction.  \n2. NFPA 72 \"Record of Completion\", filled out to the extent known at the time.  \n28 4600-1 Fire Detection and Alarm  \n3. Clear and concise description of operation, with input/output matrix similar to that shown in NFPA 72 Appendix A-7-5-2 .2(9), and complete listing of software required.  \n4. System zone boundaries and interfaces to fire safety systems.  \n5. Location of all components, circuits, and raceways; mark components with identifiers used in control unit programming.  \n6. Circuit layouts; number, size, and type of raceways and conductors; conduit fill  \ncalculations; spare capacity calculations; notification appliance circuit voltage drop calculations.  \n7. List of all devices on each signaling line circuit, with spare capacity indicated.  \n8. Manufacturer's detailed data sheet for each component, including wiring diagrams, installation instructions, and circuit length limitations.  \n9. Description of power supplies; if secondary power is by battery include calculations demonstrating adequate battery power.  \n10. Certification by either the manufacturer of the control unit or by the manufacturer of eachother component that the components are compatible with the control unit.  \n11. Certification by the manufacturer of the control unit that the system design complies with Contract Documents.  \n12. Certification by Construc","cbCaipMmeKtWWJHl","https://ap.wps.com/l/cbCaipMmeKtWWJHl","pdf",97225,"English","# 28 4600 FIRE DETECTION AND ALARM\n## PART 1 GENERAL\n### 1.01 SECTION INCLUDES\n### 1.02 RELATED REQUIREMENTS\n### 1.03 REFERENCE STANDARDS\n### 1.04 SUBMITTALS","[{\"question\":\"本节主要涵盖哪些内容？\",\"answer\":\"本节规定火灾报警系统的设计与安装要求，包括所有组件、布线与管线/导管，并涵盖与监控站通信的发射器、受保护场所到监控站的回路，以及指定的现有系统组件拆除与替换。\"},{\"question\":\"需要满足哪些相关章节要求？\",\"answer\":\"需要与多项相关系统协同，包括防火卷帘门释放要求、门五金中电控锁与门阻器由火警系统监测与释放、喷淋系统的监视/报警与执行装置、清洁剂灭火系统的监视/报警与释放装置，以及风管部件中的烟气防火阀由火警系统监测与控制。\"},{\"question\":\"本节对图纸与送审资料有什么要求？\",\"answer\":\"送审要求包括按NFPA 72填写的Record of Completion、各控制单元与通知/触发设备的制造商详细资料、设计文件用于计划审查与许可的内容（如平面图、竖向图、运行描述与输入/输出矩阵示例等），以及检查与测试计划与报告、运行与维护资料等；图纸需采用CAD .dwg格式。\"}]","FIRE DETECTION AND ALARM - SECTION 28 4600 - PART 1 GENERAL | PDF",18]