[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-664965-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-664965-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","fire-alarm-symbols-device-and-panel-designations","Fire Alarm Symbols - Device and Panel Designations","","Fire alarm symbols reference guide listing standardized codes for indicating/output devices, detector general shapes, panels, voice communication devices, and initiating (manual) devices. It maps abbreviations such as horn, horn/strobe, speaker, bell types, trouble bell, strobe light, remote light, magnetic door holder, solenoid valve, and fire/smoke damper to symbol meanings. It also covers detector types including ionization, photoelectric, heat (fixed temperature and rate-of-rise), and flame (infrared/ultraviolet), plus panel abbreviations and mounting/location subscripts.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/fire-alarm-symbols-device-and-panel-designations/664965/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/fire-alarm-symbols-device-and-panel-designations/664965.png","ImageObject",300,407,{"name":42,"@type":43},"Stanley","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What do the indicating/output device abbreviations like H and HORN/STROBE represent?","Question",{"text":62,"@type":63},"They designate the specific notification device types used in fire alarm drawings, such as a horn-only device or a horn/strobe combination.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"Which detector types are included in the detector general shape section?",{"text":67,"@type":63},"The guide lists smoke detectors (ionization, photoelectric), heat detectors (fixed temperature and rate of rise), and flame detectors (infrared and ultraviolet), plus smoke detector beam transmitter/receiver forms.",{"name":69,"@type":60,"acceptedAnswer":70},"How are panels and voice communication stations labeled in the document?",{"text":71,"@type":63},"Panels use standardized abbreviations (e.g., fire alarm panel, sprinkler alarm panel, relay panel), while 2-way voice communication devices list warden station and related variations, along with mounting method subscripts.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},664965,1793282207,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":33,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":123},2336477405376,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","| INDICATING(OUTPUT)DEVICES   |  |\n| --- | --- |\n|  | HORN   |\n| H   | HORN/STROBE   |\n| s   | SPEAKER   |\n| S   | BELL-VIBRATING   |\n| s o   | BELL(VIBRATING)/STORBE   |\n| S   | BELL(SINGLE STROBE)/STROBE   |\n| TO   | TROUBLE BELL (VIBRATING)   |\n| ST   | STROBE LIGHT   |\n| R   | REMOTE LIGHT   |\n| FL   | FLASHING LIGHT(NOT LL58/87)   |\n| DH   | MAGNETIC DOOR HOLDER   |\n| Sv   | SOLENOID VALVE   |\n| MD   | MOTORIZED FIRE/SMOKE DAMPER   |\n| R   | OUTPUT RELAY   |\n| FSD-FAN SHUTDOWN  \u003Cbr>T-TEST SWITCH  \u003Cbr>96 -96\"ABOVE FINISHED FLOOR  \u003Cbr>E-ELEVATOR RECALL  \u003Cbr>S -STAIR SPEAKER  \u003Cbr>C-CEILING MOUNTED  \u003Cbr>XXX  \u003Cbr>W-WALL MOUNTED   |  |\n| NOTE:SYMBOL ORIENTATION DOES NOT DENOTE DIRECTION OF DEVICE PROPAGATION   |  |\n\n\n| DETECTOR-GENERAL SHAPE   |  |\n| --- | --- |\n|  | SMOKE DETECTOR-IONIZATION   |\n|  | SMOKE DETECTOR-PHOTOELECTRIC   |\n|  | HEAT DETECTOR-FIXED TEMPERATURE   |\n|  | HEAT DETECTOR-RATE OF RISE   |\n|  | FLAME DETECTOR-INFRARED   |\n|  | FLAME DETECTOR-ULTRAVIOLET   |\n|  | SMOKE DETECTOR-PHOTOELECTRIC BEAM-TRANSMITTER   |\n|  | SMOKE DETECTOR-PHOTOELECTRIC BEAM-RECEIVER   |\n| S/H   | SMOKE/HEAT DETECTOR   |\n|  | AIR PRESSURE SWITCH   |\n|  | WATERFLOW SWITCH   |\n|  | TAMPER SWITCH   |\n|  | TEMPERATURE SWITCH (FREEZE-STAT)   |\n|  | HIGH/LOW WATER LEVEL   |\n|  | INCIPLENT DETECTOR   |\n| SUBSCRIPTS-LOCATION OF DEVICE  \u003Cbr>P-IN FLENUM  \u003Cbr>E-ELEVATOR DETECTOR  \u003Cbr>SS-SINGLE STAGE (SMOKE DETECTOR)  \u003Cbr>DS-DUCT-SUPPLY SIDE  \u003Cbr>DR -DUCT-RETURN SIDE  \u003Cbr>UF-UNDER THE RAISED FLOOR   |  |\n\n\n| PANELS   |  |\n| --- | --- |\n| FCS   | FIRE COMMAND STATION   |\n| FAP   | FIRE ALARM PANEL   |\n| SAP   | SPRINKLER ALARM PANEL   |\n| RP   | RELAY PANEL   |\n| DGP   | DATA GATHERING PANEL(MULTIPLEX SYSTEMS)   |\n| AMP   | AMPLIFIER RACK   |\n| PP   | PURGE PANEL   |\n| SCP   | SMOKE CONTROL PANEL   |\n| DP   | SPRINKLER DELUGE PANEL   |\n| SP   | STROBE PANEL   |\n| PA   | PUBLIC ADDRESS PANEL   |\n| RA   | REMOTE ANNUNCIATOR   |\n| GA   | GRAPHIC ANNUNCIATOR   |\n| J   | JUNCTION BOX   |\n| FCO   | FUSE CUT OUT   |\n| COT   | CENTRAL OFFICE TRANSMIITER   |\n| HCP   | HALON CONTROL PANEL   |\n| SCBA   | SELF-CONTAINED BREATHING APPARATUS   |\n\n\n| 2-WAY VOICE COMMUNICATION DEVICES   |  |\n| --- | --- |\n| WS   | WARDEN STATION   |\n| WJ   | WARDEN JACK   |\n| WS  \u003Cbr>PR   | WARDEN STATION IN PUMP ROOM (25”CORD)   |\n| wS  \u003Cbr>FSD   | WARDEN STATION IN FIRE SAFETY DIRECTOR'S OFFICE   |\n| SK   | STRAP KEY   |\n| SUBSCRIPTS-MOUNTING METHOD  \u003Cbr>S-SURFACE  \u003Cbr>SF-SEMI FLUSH  \u003Cbr>F-FLUSH   |  |\n| INITIATING(MANUAL)DEVICES   |  |\n| F   | MANUAL FIRE PULL STATION   |\n| A   | ABORT SWITCH   |\n| MR   | HALON MAIN/RESERVE SWITCH   |\n| SUBSCRIPTS-MOUNTING METHOD  \u003Cbr>1-2-4-INDIVIDUAL CORD FOR PULL  \u003Cbr>S-SURFACE  \u003Cbr>STATION(INDICATE CODE FOR IND.  \u003Cbr>SF-SEMI FLUSH  \u003Cbr>XXX  \u003Cbr>CODED SYSTEM)  \u003Cbr>F-FLUSH   |  |","cbCaipJYVcgu3pDA","https://ap.wps.com/l/cbCaipJYVcgu3pDA","pdf",190154,"English","# Indicating (Output) Devices\n## Detector General Shape\n## Panels\n## 2-Way Voice Communication Devices\n## Initiating (Manual) Devices","[{\"question\":\"What do the indicating/output device abbreviations like H and HORN/STROBE represent?\",\"answer\":\"They designate the specific notification device types used in fire alarm drawings, such as a horn-only device or a horn/strobe combination.\"},{\"question\":\"Which detector types are included in the detector general shape section?\",\"answer\":\"The guide lists smoke detectors (ionization, photoelectric), heat detectors (fixed temperature and rate of rise), and flame detectors (infrared and ultraviolet), plus smoke detector beam transmitter/receiver forms.\"},{\"question\":\"How are panels and voice communication stations labeled in the document?\",\"answer\":\"Panels use standardized abbreviations (e.g., fire alarm panel, sprinkler alarm panel, relay panel), while 2-way voice communication devices list warden station and related variations, along with mounting method subscripts.\"}]","Fire Alarm Symbols - Device and Panel Designations | PDF"]