[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-663782-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-663782-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","fire-alarm-checklist","Fire Alarm Checklist","","Fire Alarm Checklist provides a detailed plan review submission and design requirement set for new systems, tenant remodels, and replacements. It specifies general building information and pass/fail status, and lists drawing submittal deliverables such as scaled drawings, room labels, legends with quantities, riser diagrams, sequence-of-operations matrices, wire legends, penetration details, and equipment/data documentation. It further covers initiating devices placement, notification appliance performance targets, and required locations and notes for voice evacuation, strobes, and related interfaces under NFPA standards and local ordinance references.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/fire-alarm-checklist/663782/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/fire-alarm-checklist/663782.png","ImageObject",300,407,{"name":42,"@type":43},"Indoniesian Boy","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":26},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What drawing and documentation sets must be submitted for the fire alarm plan review?","Question",{"text":62,"@type":63},"Submit three sets of drawings, including equipment technical data sheets, voltage drop and battery calculations, a scope of work letter copy, and a CD with required PDF documents such as drawings, scope letter, and component data sheets plus the calculations.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What scale and labeling requirements apply to the submitted drawings?",{"text":67,"@type":63},"Drawings must be to scale with a graphic scale (1/8” = 1 ft preferred). All rooms must be labeled, and a legend/key for all fire alarm components must be included with quantities.",{"name":69,"@type":60,"acceptedAnswer":70},"What notification appliance performance requirements are specified for audible alerts?",{"text":71,"@type":63},"Provide audible notification to achieve 15 dB above average ambient sound level throughout the building or space, and provide audible notification at a minimum of 75 dB at the pillow level in sleeping areas.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},663782,1793231726,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},7,40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":26,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":96},962090760608,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Fairburn Fire Department  \n\n| Fire Marshal’s Office\u003Cbr>\u003Cbr>Plan Review | Fire Alarm Checklist 1\u003Cbr>Job Name:  Address:  Bldg:   Suite:  City:   Zip:  Responsible Party:  Phone:  Fire Alarm Company: Building Permit \\# : |  |\n| --- | --- | --- |\n|  | GENERAL BUILDING INFORMATION:\u003Cbr>Occupancy Type  Occupant Load \u003Cbr>New System 􀂉 Tenant Remodel 􀂉 Replacement 􀂉\u003Cbr>Fire Sprinkler System Present Y􀂉 N􀂉 Voice Evacuation Y􀂉 N􀂉\u003Cbr>Special Locking Arrangements2 Y􀂉 N􀂉 Fire Pump Present Y􀂉 N􀂉 |  |\n| 􀀹 = Pass, X = Fail, NA = Not applicable |  | Status |\n| DRAWING SUBMITTAL REQUIREMENTS |  |  |\n| 1) Provide three (3) sets of drawings, one (1) set of the equipment technical data sheets, voltage drop calculations, battery calculations, and a copy of the scope of work letter |  |  |\n| 2) Drawings must be to scale with a graphic scale (1/8” = 1 ft scale is preferred) |  |  |\n| 3) Label all rooms |  |  |\n| 4) Provide legend/key for all fire alarm components and include the quantities; the fire alarm symbols must comply with the 2018 edition of NFPA 170 (NFPA 72: 7.2.3) |  |  |\n| 5) Provide a CD that includes the following documents in PDF: drawings, scope of work letter, equipment technical data sheets for each component, voltage drop and battery calculations |  |  |\n| 6) Indicate the person responsible for the system design on the drawing (NFPA 72: 7.2.2) |  |  |\n| 7) Provide a copy of the low voltage with name, license \\#, and original signature of license holder on the drawings |  |  |\n| 8) Provide a riser diagram (NFPA 72: 7.2.1(2)) |  |  |\n| 9) Provide a sequence of operation in an input/output matrix (NFPA 72: 7.2.1(4)) |  |  |\n| 10) Provide a wire legend (specify wire type and size), show point to point system wiring, EOLR locations Note: SLC, NAC or other circuits shown in different colors is preferred |  |  |\n| 11) Provide penetration details for fire barrier/walls or smoke barriers; must indicate if wiring isin a plenum space |  |  |\n| 12) Show the location of FACP and remote power supplies with smoke detectors3 |  |  |\n| 13) Show the location of the documentation cabinet for new fire alarm systems (NFPA 72: 7.7.2) |  |  |\n| 14) Show the location of the Knox Box and the fire alarm annunciator; annunciator must be within 10 ft of the main fire department entrance |  |  |\n| INITIATING DEVICES |  |  |\n| 15) Show the location of manual fire alarm boxes; within 5 ft of exit doors (NFPA 72: [17.14.8.4](17.14.8.4)); provide additional manual fire alarm boxes every 200 ft of travel (NFPA 72: [17.14.8.5](17.14.8.5)) |  |  |\n| 16) Show the location of smoke detectors where required by NFPA 72 and/or NFPA 101; Note: To minimize the probability of false alarms non-required smoke detectors should not be installed |  |  |\n| 17) Show the location of detectors in air duct systems; Note: Detectors located in air ducts shall report as supervisory only (NFPA 72: [17.7.5.5](17.7.5.5)) |  |  |\n| 18) Show the location of other smoke sensing detectors (i.e. beam detectors or air sampling smoke detectors) |  |  |\n| 19) Show the location of smoke detectors for the operation of smoke dampers |  |  |\n| 20) Show the location of heat detectors in elevator shafts with sprinklers and where required by code or due to weather conditions (NFPA 72: 17.6.1) |  |  |\n| 21) Show the interface with the kitchen hood/suppression system (NFPA 72: 17.13) |  |  |\n| 22) Show the location of sprinkler flow switches for electronic monitoring ( NFPA 72: 17.12) |  |  |\n| 23) Show the location of other automatic extinguishing systems (i.e. clean agent system or foam system) (NFPA 72: 17.13) |  |  |\n| 24) Show the location of all tamper switches for electronic monitoring of all sprinkler control valves including the PIV (City Ordinance Section 29-7 and NFPA 72: 17.16.1) |  |  |\n| 25) Provide pressure supervisory signal-initiating device and off-normal signal for pressure increases and decreases for dry-pipe sprinkler system (NFPA 72: 17.16.2.2.2) |  |  |\n\n\n| 26) Provide monitoring of fir","cbCainGrgbYpNImJ","https://ap.wps.com/l/cbCainGrgbYpNImJ","pdf",166721,"English","# Fire Marshal’s Office Plan Review - Fire Alarm Checklist\n## Drawing Submittal Requirements\n## General Building Information\n## Initiating Devices\n## Notification Appliances","[{\"question\":\"What drawing and documentation sets must be submitted for the fire alarm plan review?\",\"answer\":\"Submit three sets of drawings, including equipment technical data sheets, voltage drop and battery calculations, a scope of work letter copy, and a CD with required PDF documents such as drawings, scope letter, and component data sheets plus the calculations.\"},{\"question\":\"What scale and labeling requirements apply to the submitted drawings?\",\"answer\":\"Drawings must be to scale with a graphic scale (1/8” = 1 ft preferred). All rooms must be labeled, and a legend/key for all fire alarm components must be included with quantities.\"},{\"question\":\"What notification appliance performance requirements are specified for audible alerts?\",\"answer\":\"Provide audible notification to achieve 15 dB above average ambient sound level throughout the building or space, and provide audible notification at a minimum of 75 dB at the pillow level in sleeping areas.\"}]","Fire Alarm Checklist | PDF"]