[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663780-105":59,"doc-detail-663780-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","fire-alarm-backup-typical-single-line-diagram","FIRE ALARM BACKUP - Typical Single Line Diagram","","Typical single line diagram documentation for a fire alarm backup system, detailing the system’s cabinet components and installation configurations. Includes notes on static/manual bypass behavior and optional dotted-block features, plus mounting selection checklists for standard versus seismic mounting options (e.g., zone 4) and references to seismic drawings. Provides battery cabinet layouts for multiple sizes (A through D), including electronic and battery cabinet specifications, dimensions in inches, mounting hole notes, and recommended system layout battery configuration durations by power rating.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/fire-alarm-backup-typical-single-line-diagram/663780/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/fire-alarm-backup-typical-single-line-diagram/663780.png","ImageObject",300,407,{"name":92,"@type":93},"Blue Pony","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the static bypass and manual bypass behaviors mentioned in the notes?","Question",{"text":112,"@type":113},"The notes state that the system will be powered from the transformer for different input and output voltage configurations.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the mounting selection work for battery/electronic cabinets?",{"text":117,"@type":113},"The document provides a checklist for standard mounting and seismic mounting (with references to note #2 and zone 4 installation guidance).",{"name":119,"@type":110,"acceptedAnswer":120},"Which battery cabinet sizes are covered and what is their basis?",{"text":121,"@type":113},"The document includes layouts for \"B\" size, \"C\" size, and \"D\" size battery cabinets, each described as standard VRLA battery configurations with recommended system layouts and selection checklists.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663780,1793231687,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},962090760266,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","# FIRE ALARM BACKUP TYPICAL SINGLE LINE DIAGRAM\n\n|  |  | TYPICAL  \u003Cbr>FIRE ALARM BACKUP  \u003Cbr>SINGLE LINE DIAGRAM   |  |\n| --- | --- | --- | --- |\n| SDRM.TANG   | 12/1/23   | DWG NO.:  \u003Cbr>145-TD-010   | REV.:B   |\n| APPVD.SHERRI   | 12/1/23   |  | SHT1 OF1   |\n| CHKD:HAI   | 12/123   | SUBJECT TOCHANGEWITHOUTNOTICE   |  |\n\n## NOTES:\n\n1.*Static Bypass and Manual Bypass:  \nWillbe powered from the transformer for differentinput and output voltage configurations.  \n## 2.Dotted blocks are optional features.\n\nFIRE ALARM BACKUP SYSTEM CABINET A  \nELECTRONIC CABINET  \n(0.5 KW-15 KW)  \n## SIDE VIEWBACK VIEWFRONT VIEW\n\n—0.75      26.13-    0.822437(4X)LEVELING PAD(4X)  \n\n| BATTERY CABINET MOUNTING SELECTION CHECKLST   |  |\n| --- | --- |\n| □STANDARD   | □SEISMIC   |\n| MOUNTING   | MOUNTING   |\n|  | SEE NOTE\\#2   |\n\n12.88  \n2.52.5INSTALLATION WI SEISMIC BRACKETS  \nFOR ZONE 4 BOTTOM VIEWBOTTOM VIEWNOTES:  \nBATTERY CONFIG.SELECTION CHECKLIST  \n□ 0.5KW……15 MIN.□ 1.5KW……15MIN.  \n□ 0.5KW……30MIN.□ 1.5KW……30 MIN.  \n□ 0.5KW……60MIN.□ 2KW………15 MIN.  \n□ 0.75KW...15 MIN.□ 2KW…………30 MIN.  \n□ 0.75KW.……30 MIN.□3KW…………15 MIN.  \n1.ALL DIMENSIONS SHOWN ARE APPROXIMATE &IN INCHES.  \n□ 0.75KW……60 MIN.□ 4KW……15 MIN.  \n2.OPTIONAL SEISMIC BRACKETS AVALABLE  \n□ 1KW……15 MIN.  \n3.CABINET QUANTITY:  \n□ 1KW………30 MIN.  \n● ELECTRONIC CABINET=1  \n□ 1KW……60 MIN.  \n● BATTERYCABINET=1  \n4.RATING:  \n\n| Line  \u003Cbr>····POW E R   |  | FIRE ALARM BACKUP  \u003Cbr>ELECTRONIC CABINET   |  |\n| --- | --- | --- | --- |\n| SDR:M.TANG   | 12/13/23   | DWG NO.:  \u003Cbr>145-TD-011   | REV.:B   |\n| APPVD:SHERRI   |  12/13/23   |  | SHT1 OF1   |\n| CHKDHAl   | 12/13/23[   | SUBJECT TO CHANGE WITHOUTNOTICE   |  |\n\n● 3 KVA,SINGLE PHASE  \n● 120 VOLTS INPUT,120 VOLTSOUTPUT  \n● 24 HOURS BATTERY BACKUP TIME MAXIMUM  \n5.CABINET WEIGHT:  \n● ELECTRONC CABINET=320 LBS.  \n● BATTERY CABINET=600 LBS (WVBATTERIES)  \n## \"B\"SIZE BATTERY CABINETSTANDARD VRLA BATTERY\n\nRECOMMENDED SYSTEM LAYOUTS  \nBATTERY CONFIG.SELECTION CHECKLIST  \n□ 0.5KW……120 MIN.  \n□ 2.0KW………60 MIN.  \n□ 0.5KW……180 MIN.  \n□ 2.0KW……120 MIN.  \n□ 0.5KW……240 MIN.  \n□ 2.0KW……180 MIN.  \n□ 0.5KW……360 MIN.  \n□ 2.0KW……240 MIN.  \n□ 0.5KW……480 MIN.  \n□ 3.0KW.…………30MIN.  \n□ 0.75KW……120 MIN.  \n□ 3.0KW………60 MIN.  \nTOP VIEWFRONT VIEWSIDE VIEWBOTTOM VIEWBATTERYCABINET MOUNTINGINSTALLATION WITH EXTERNAL SEISMIC□STANDARDMOUNTINGBRACKETS FOR ZONE 4 BOTTOM VIEW  \n□ 0.75KW…180 MIN.  \n□ 3.0KW……120 MIN.  \n□ 0.75KW240 MIN.  \n□ 3.0KW………180 MIN.  \n□ 0.75KW……360 MIN.  \n□ 4.0KW…………30MIN.  \n□ 0.75KW.……480 MIN.  \n□ 4.0KW………60 MIN.  \n□ 1KW……120 MIN.  \n□ 4.0KW……120 MIN.  \n□ 1KW………180 MIN.  \n□ 4.0KW……180 MIN.  \n□ 1KW………240 MIN.  \n□ 5.0KW…………15MIN.  \n□ 1KW………360 MIN.  \n□ 5.0KW……30 MIN.  \n□ 1KW…………480 MIN.  \n□ 5.0KW…  …60 MIN.  \n□ 1.5KW………60 MIN.  \n□ 5.0KW……120 MIN.  \n□ 1.5KW……120 MIN.  \n□ 1.5KW………180 MIN.  \n□ 1.5KW………240 MIN.  \n□ 1.5KW………360 MIN.  \n| B   | 1.0°   | 8.0\"   |\n| --- | --- | --- |\n| A   | 1.0°   | 4.0\"   |\n| DIM   | WTHOUT  \u003Cbr>EXTERNAL  \u003Cbr>SEISMIC   | WITH  \u003Cbr>EXTERNAL  \u003Cbr>SEISMIC   |\n\n□SEISMICMOUNTINGSEE NOTE\\#2BOTTOM VIEWNOTES:  \n1)EACHBATTERYCABINETINCLUDES1 BATTERYBREAKER  \n2)CONSTRUCTION:NEMA 1INDOOR  \n3)OPTIONAL SEISMIC BRACKETSAVAILABLE  \n\n| PoW E R   |  | FIRE ALARM BACKUP  \u003Cbr>BATT CAB,48\"HIGH   |  |\n| --- | --- | --- | --- |\n| SDR:MT   | 12/14/23   | DWG NO.:  \u003Cbr>145-TD-012   | REV.:B   |\n| APPVD:SS   | 12/1423   |  | SHT10F1   |\n| CHKD:HN   | 12/1423   | SUBJECT TO CHANGE WITHOUTNOTICE   |  |\n\n4)FORANCHORINGINFO.,REFER TO SEISMIC DRAWING  \n5)ALL DIMENSIONS ARE IN INCHES  \n6)KNOCKOUT FOR 3/4\"OR 1\"CONDUIT  \n7)KNOCKOUT FOR 1.5\"OR 2\"CONDUIT  \n8)OPTIONAL RACKS AVAILABLEFOR STACKING BATTERY CABINETS  \n9)CONSULTFACTORYFORBATTERY CONFIGURATIONSOR LAYOUTS NOT SHOWNINDRAWING(L.E.7.5KW-15KW)  \nRECOMMENDED SYSTEM LAYOUTS  \nBATTERY CONFIG.SELECTION CHECKLIST  \n                    □ 5KW…………180 MIN.NOTE \\#4                     BATTERY      BREAKER        10.75FRONT VIEWSIDE VIEW34.752.1314Ø.69(4X)      ((REFER TO SEISMIC DWG)  \n□ 0.5KW……1440 MIN.  \n                 ","cbCainPNHlriE5C2","https://ap.wps.com/l/cbCainPNHlriE5C2","pdf",3062017,"English","# FIRE ALARM BACKUP TYPICAL SINGLE LINE DIAGRAM\n## NOTES\n## FIRE ALARM BACKUP SYSTEM CABINET\n## BATTERY CONFIG. SELECTION CHECKLIST\n## \"B\" SIZE BATTERY CABINET\n## RECOMMENDED SYSTEM LAYOUTS\n## \"C\" SIZE BATTERY CABINET\n## INSTALLATION WITH SEISMIC BRACKETS FOR ZONE 4\n## \"D\" SIZE BATTERY CABINET","[{\"question\":\"What are the static bypass and manual bypass behaviors mentioned in the notes?\",\"answer\":\"The notes state that the system will be powered from the transformer for different input and output voltage configurations.\"},{\"question\":\"How does the mounting selection work for battery/electronic cabinets?\",\"answer\":\"The document provides a checklist for standard mounting and seismic mounting (with references to note #2 and zone 4 installation guidance).\"},{\"question\":\"Which battery cabinet sizes are covered and what is their basis?\",\"answer\":\"The document includes layouts for \\\"B\\\" size, \\\"C\\\" size, and \\\"D\\\" size battery cabinets, each described as standard VRLA battery configurations with recommended system layouts and selection checklists.\"}]","FIRE ALARM BACKUP - Typical Single Line Diagram | PDF",15]