[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-562770-105":59,"doc-detail-562770-en":124},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":117,"head_meta":119,"extra_data":121,"updated_unix":123},105,"hu","fan-7529-pfc-controller-pinout-fault-symptom","FAN 7529 PFC kontroller - Lábkiosztás, hibajelenség","","A FAN 7529 PFC kontroller lábkiosztása és a funkciók leírása kerül bemutatásra, részletesen az invertáló hibajel-erősítő bemenet (INV), a hibajel-erősítő kimenet (COMP), a belső fűrészjel lejtés beállítása (MOT), valamint a túláram-védelem komparátorának bemenete (CS) és a nullérzékelés (ZDC). Megadják a csatlakoztatási elveket, küszöbértékeket, például 0,8 V komparátor küszöb és 1,5 V/1,4 V kapcsolási tartomány, továbbá a működési feltételeket (GND szétválasztás, gate áramút induktivitásának minimalizálása). A hiba okai is szerepelnek: az alacsony PFC kimeneti feszültség bizonytalan főtápüzemet és leállásokat okoz, több lehetséges okkal (IN referencia osztó módosulása, gyártási szórás miatti egyedi osztóbeállítás, illetve hibás IC).",{"@graph":69,"@context":116},[70,84,99],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/fan-7529-pfc-controller-pinout-fault-symptom/562770/",{"url":83,"name":65,"@type":85,"author":86,"headline":65,"publisher":89,"fileFormat":92,"inLanguage":63,"description":67,"dateModified":93,"datePublished":93,"encodingFormat":92,"isAccessibleForFree":94,"interactionStatistic":95},"DigitalDocument",{"name":87,"@type":88},"hdkawk","Person",{"url":74,"name":90,"@type":91},"DocShare","Organization","application/octet-stream","2026-10-12",true,{"@type":96,"interactionType":97,"userInteractionCount":4},"InteractionCounter",{"@type":98},"ViewAction",{"@type":100,"mainEntity":101},"FAQPage",[102,108,112],{"name":103,"@type":104,"acceptedAnswer":105},"Mi okozza a hibajelenséget a FAN 7529 PFC kontrollerben?","Question",{"text":106,"@type":107},"A PFC kimeneti feszültség (névleg 400 V, a fuffer kondenzátoron mérve) alacsony, ezért a főtáp bizonytalanul jár, kikapcsolgat, vagy el sem indul.","Answer",{"name":109,"@type":104,"acceptedAnswer":110},"Hogyan kapcsolódik az INV és mit kell beállítani?",{"text":111,"@type":107},"Az INV lábra a PFC kimeneti DC jeléből egy ellenállásos osztóval 2,5 V-ot kell visszavezetni; az osztási arány módosításával a kimeneti DC nagysága állítható.",{"name":113,"@type":104,"acceptedAnswer":114},"Milyen tartományoknál kapcsol a ZDC (nullérzékelő) és mi a hatása?",{"text":115,"@type":107},"Ha a ZDC feszültsége 1,5 V fölé emelkedik, majd 1,4 V alá csökken, a PMOSFET ON állapotba kapcsolódik és vezetni kezd.","https://schema.org",{"og:url":83,"og:type":118,"og:title":65,"og:site_name":90,"og:description":67},"article",{"robots":120,"canonical":83},"index,follow",{"doc_id":122,"site_id":62},562770,1791809698,{"code":4,"msg":5,"data":125},{"doc_id":122,"user_id":126,"nickname":87,"user_avatar":127,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":128,"file_id":129,"file_url":130,"file_type":131,"file_size":132,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":133,"language_code":63,"site_id":62,"html_lang":134,"table_of_contents":135,"faqs":136,"seo_title":137,"seo_description":67,"update_tm":123,"read_time":24},3985747859855,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","FAN 7529\nPFC kontroller\nLáb\nNeve\nFunkciója\nINV\nEz a láb a hibajel-erősítő invertáló bemenete. Ide a PFC kimeneti DC jeléből egy ellenállás osztóval 2,5V-ot kell visszavezetni. Itt állítható be (az osztási arány módosításával) a kimeneti DC nagysága.\nCOMP\nEz a láb a  hibajel-erősítő kimenete. A kimeneti feszültség-kompenzáció külső RC elemeit kell ide csatlakoztatni. A láb üzemi feszültsége 1-5V.\nMOT\nEz a láb a belső fűrészjel lejtésének beállítására szolgál. A láb feszültsége stabilan 2,9V. Ha a láb és a föld közé egy ellenállást kötünk be, áram folyik ki a lábon, és így a belső fűrészjel lejtése arányos lesz ezzel az árammal. Ettől függ a PMOSFET maximális  ON ideje.\nCS\nEz a láb a túláram-védelem komparátorának bemenete. A kapcsoló PMOSFET áramát egy (a source és a föld közé kötött) áramfigyelő ellenállás érzékeli, amin eső feszültséget kell erre a lábra vezetni. A komparátor bemenetétől egy belső RC szűrő tartja távol a kapcsolási zajt. Az érzékelési küszöbszint 0,8V.\nZDC\nEz a láb a nullérzékelő blokk  bemenete. Ha ennek a lábnak a feszültsége 1,5V fölé emelkedik, majd ezt követően 1,4V alá csökken,  a PMOSFET  „ON” állapotba kapcsolódik (vezetni kezd). A láb bemeneti feszültsége 6,7V-on limitált.\nGND\nEz a jelföld láb biztosítja az összes többi láb számára a 0 potenciált (földpontot). A helyes működéshez a jelföldet és a teljesítményföldet el kell választani.\nOUT\nEz a láb a kapcsoló PMOSFET gate elektródáját vezérlő kimenet. A láb maximális ismétlődő forrásárama és visszárama +500uA és -800uA. A helyes működéshez a gate elektródáig vezető áramköri út járulékos induktivitását minimalizálni kell.\nVcc\nEz a láb az IC tápfeszültség lába. Az IC által fogyasztott áramnak, és a PMOSFET meghajtó áramának  összege adja az itt szükséges  tápáramot. Az IC működése 12V-nál indul, és  8,5V alatt leáll. Vcc értéke 22V-nál limitált egy belső Zener dióda által.\nHibajelenség:\nA PFC kimeneti feszültsége (névleg 400V, a fuffer kondenzátoron mérve) alacsony, emiatt a készülék főtápja bizonytalanul jár, kikapcsolgat, vagy el sem indul.\nOka1:\nMegváltoztak a kimenetről az 1-es (IN) lábra feszültséget adó referencia osztó elemei. Cseréljük az ellenállásokat jobb minőségűre.\nOka2:\nAz IC-k gyártási szórása (ami elég nagy) miatt az osztó osztási arányát egyedileg (potméterrel) célszerű beállítani.\nOka3:\nHibás a PFC kontroller IC.","cbCaiaqLAMo6x5no","https://ap.wps.com/l/cbCaiaqLAMo6x5no","doc",20480,"Hungarian","en","# FAN 7529 PFC kontroller lábkiosztás\n## INV, COMP és a hibajel-erősítő\n## MOT és a fűrészjel lejtése\n## CS és a túláram-védelem\n## ZDC és a nullérzékelés\n## GND, OUT és Vcc működési feltételek\n# Hibajelenség és lehetséges okok","[{\"question\":\"Mi okozza a hibajelenséget a FAN 7529 PFC kontrollerben?\",\"answer\":\"A PFC kimeneti feszültség (névleg 400 V, a fuffer kondenzátoron mérve) alacsony, ezért a főtáp bizonytalanul jár, kikapcsolgat, vagy el sem indul.\"},{\"question\":\"Hogyan kapcsolódik az INV és mit kell beállítani?\",\"answer\":\"Az INV lábra a PFC kimeneti DC jeléből egy ellenállásos osztóval 2,5 V-ot kell visszavezetni; az osztási arány módosításával a kimeneti DC nagysága állítható.\"},{\"question\":\"Milyen tartományoknál kapcsol a ZDC (nullérzékelő) és mi a hatása?\",\"answer\":\"Ha a ZDC feszültsége 1,5 V fölé emelkedik, majd 1,4 V alá csökken, a PMOSFET ON állapotba kapcsolódik és vezetni kezd.\"}]","FAN 7529 PFC kontroller - Lábkiosztás, hibajelenség | DOC"]