[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-505431-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-505431-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","facilities-management-refrigerants-ozone-depletion-training-chapter-1-basic-refrigerant-management-requirements","Facilities Management: Refrigerants & Ozone Depletion - Training Chapter 1 - Basic Refrigerant Management Requirements","","Facilities Management: Refrigerants & Ozone Depletion training material explains how refrigerants are used for heat transfer in cooling systems and how CFCs contributed to stratospheric ozone depletion discovered in the 1970s. It describes the protection role of ozone against harmful UV radiation, the international response through the 1987 Montreal Protocol, and downstream health risks from ozone loss. The training outlines U.S. Clean Air Act Title VI requirements for safe handling, EPA oversight, and definitions for recycled, reclaimed, and recovered refrigerants, plus GSA responsibilities to prevent purchases of nonessential Class I products containing CFCs.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/facilities-management-refrigerants-ozone-depletion-training-chapter-1-basic-refrigerant-management-requirements/505431/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/facilities-management-refrigerants-ozone-depletion-training-chapter-1-basic-refrigerant-management-requirements/505431.png","ImageObject",300,407,{"name":42,"@type":43},"xXChrisXx","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-06","2026-10-04",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the role of refrigerants in building cooling systems?","Question",{"text":63,"@type":64},"A refrigerant is a fluid used for heat transfer in a cooling system, supporting air conditioning and refrigeration operations.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How did the Montreal Protocol relate to CFC phaseout in the U.S.?",{"text":68,"@type":64},"The 1987 Montreal Protocol prompted international concern and commitments to phase out CFCs and other ozone-depleting substances (ODSs). In the U.S., it led to amendments including Clean Air Act Title VI provisions for EPA management of the phaseout.",{"name":70,"@type":61,"acceptedAnswer":71},"What are the differences between recycled, reclaimed, and recovered refrigerants?",{"text":72,"@type":64},"Recycled refrigerant is extracted and cleaned for reuse without meeting stringent reclamation requirements; reclaimed refrigerant is reprocessed with specialized machinery and tested to meet industry purity standards; recovered refrigerant is removed from equipment and stored in an external container without necessarily being tested or processed.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},505431,1791160316,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":97,"preview_urls":146},8796112263567,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Facilities Management: Refrigerants & Ozone Depletion  \nTraining Chapter 1 of 6  \nPrepared for: GSA Building Managers  \nPrepared by: PBS Environment Program Team  \nDate: January 2008  \nPBS Environment Division  \nFacilities Management: Refrigerants & Ozone Depletion  \n􀀗 GSA uses and stores refrigerants for a variety of building operation applications. A refrigerant is a fluid that is used for heat transfer in a cooling system.  \n􀀗 Historically, chlorofluorocarbons (CFCs) were used extensively as refrigerants in the air conditioning and refrigeration industries. In the 1970s, scientists discovered these substances deplete the stratospheric ozone layer in the upper atmosphere. The stratospheric ozone layer protects us from the sun's harmful ultraviolet (UV) radiation.  \n􀀗 This discovery led to international concern about ozone depletion. In 1987, the U.S., along with other countries, made a commitment to phase out CFCs and other ozone depleting substances (ODSs) through the Montreal Protocol on Substances that Deplete the Ozone Layer.  \nPBS Environment Division 2  \nFacilities Management: Refrigerants & Ozone Depletion  \n􀀗 NASA provides us with a historical record of images of the ozone hole over Antarctica. In this image, the purple and blue area represents ozone loss catalyzed from chlorine and bromine compounds, like R-11 and methyl bromide.  \nPBS Environment Division  3  \nFacilities Management: Refrigerants & Ozone Depletion  \n􀀗 Depletion of the stratospheric ozone layer leads to overexposure to harmful UV radiation at the earth's surface.  \nExcessive UV radiation increases the risk of melanoma and other types of skin cancer.  \nExcessive UV radiation increases the risk of cataract formation.  \nPBS Environment Division  \nFacilities Management: Refrigerants & Ozone Depletion  \n􀀗 The Montreal Protocol led to an amendment of the Clean Air Act (CAA) in 1990 to include Title VI, Stratospheric Ozone Protection.  \n– Title VI authorizes the U. S. Environmental Protection Agency (EPA) to manage the phaseout of ODSs. Among the regulations established by the EPA are requirements for the safe handling of ODSs and prohibitionson the known venting or release of ODSs into the atmosphere. As ODSs are phased out, surplus ODS must be stored, reused (after recycling or reclamation), or destroyed.  \n􀀗 DEFINITIONS  \n– A recycled refrigerant has been extracted and cleaned for reuse without meeting the stringent requirements for reclamation.  \n– A reclaimed refrigerant has been reprocessed using specialized machinery and tested to meet industry purity standards.  \n– A recovered refrigerant is one that was removed from refrigeration or airconditioning equipment and stored in an external container without necessarily being tested or processed in any way.  \nPBS Environment Division  5  \nFacilities Management: Refrigerants & Ozone Depletion  \n􀀗 Under the CAA, EPA regulations phase out the production and import (not use) of ODSs.  \n– ODSs are regulated as either Class I or Class II controlled substances, as shown below.  \n􀀗 Class I ODSs have been completely phased out in the  \nU.S. The phaseout of Class IIODSs is in progress.  \n– For a complete list of ODSs, CLICK here.  \n\n| Class I ODS | Class II ODS |\n| --- | --- |\n| Cloroflurocarbon (CFCs) compounds | Hydrochloroflurocarbon (HCFCs) compounds |\n| Bromide compounds (Halons) | R-22 (HCFC) |\n| Carbon tetrachloride | HCFC-123 |\n| Methyl bromide |  |\n| Methyl chloride |  |\n\nPBS Environment Division  6  \nFacilities Management: Refrigerants & Ozone Depletion  \n􀀗 The CAA requires federal agencies to meet specific requirements when handling and disposing of refrigerants and servicing, maintaining, and disposing of air conditioning and refrigeration equipment.  \n􀀗 Also, federal regulations prohibit the buying and selling of products listed as Nonessential Class I Products (as defined by  \n40 CFR 82.66) . These are products and equipment that contain and release CFCs.  \n􀀗 GSA must not purchase Nonessential Class I","cbCailL047ydL9VZ","https://ap.wps.com/l/cbCailL047ydL9VZ","pdf",218050,45,"English","# Facilities Management: Refrigerants & Ozone Depletion\n## Refrigerants and Ozone Depletion Background\n## Montreal Protocol and Health Impacts\n## Clean Air Act Title VI and EPA Oversight\n## Definitions: Recycled, Reclaimed, Recovered\n## ODS Phaseout, Classes, and Compliance Requirements\n## GSA Responsibilities and Training Objectives\n# Refrigerant Management Requirements (Chapter 2)\n## HCFC Phaseout Schedule","[{\"question\":\"What is the role of refrigerants in building cooling systems?\",\"answer\":\"A refrigerant is a fluid used for heat transfer in a cooling system, supporting air conditioning and refrigeration operations.\"},{\"question\":\"How did the Montreal Protocol relate to CFC phaseout in the U.S.?\",\"answer\":\"The 1987 Montreal Protocol prompted international concern and commitments to phase out CFCs and other ozone-depleting substances (ODSs). In the U.S., it led to amendments including Clean Air Act Title VI provisions for EPA management of the phaseout.\"},{\"question\":\"What are the differences between recycled, reclaimed, and recovered refrigerants?\",\"answer\":\"Recycled refrigerant is extracted and cleaned for reuse without meeting stringent reclamation requirements; reclaimed refrigerant is reprocessed with specialized machinery and tested to meet industry purity standards; recovered refrigerant is removed from equipment and stored in an external container without necessarily being tested or processed.\"}]","Facilities Management: Refrigerants & Ozone Depletion - Training Chapter 1 - Basic Refrigerant Management Requirements | PDF",1791148100,113,[147,151,154,158,162],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d65d9a34672d53515a14440a6f09d69e.webp",983,736,{"page_no":26,"url":152,"width":153,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6df53760b17d643fc19104e5fe0aad8c.webp",982,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/596348f4aa90d117153eafa857daf179.webp",981,735,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/47cdfa17c28b591847408d68416914e9.webp",980,734,{"page_no":97,"url":163,"width":164,"height":165},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ac9a0366f46944c6d5180862e602620a.webp",979,733]