[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-638592-105":59,"doc-detail-638592-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","f7-data-logger-datasheet-technical-specifications","F7 Data Logger - Datasheet - Technical Specifications","","F7 Data Logger is a rugged, high-performance system for remote environmental monitoring, designed for wildfire risk management. It combines durability, low power consumption, and solar charging with optional satellite communication for dependable field data collection. Key capabilities include an IP67 sealed enclosure, military-grade connectors, dynamic logging with post-hoc construction, CSV downloads, multiple SDI-12 sensor ports, and integrated GOES/Iridium telemetry. A touchscreen interface, robust electrical protection, extensive sensor compatibility, and long logging capacity support safety-critical weather station applications.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/f7-data-logger-datasheet-technical-specifications/638592/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/f7-data-logger-datasheet-technical-specifications/638592.png","ImageObject",300,407,{"name":92,"@type":93},"McQueen","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the main intended uses of the F7 Data Logger?","Question",{"text":112,"@type":113},"The F7 Data Logger is designed for remote environmental monitoring with a focus on wildfire risk management applications, supporting reliable data collection in harsh environments.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the F7 handle power and charging in the field?",{"text":117,"@type":113},"The system supports 12 V battery input and solar input (standard 20 W, site-dependent options). Charge regulation includes voltage/current control with temperature compensation.",{"name":119,"@type":110,"acceptedAnswer":120},"Which sensor connection options and telemetry interfaces are available?",{"text":121,"@type":113},"F7 provides four SDI-12 sensor ports plus an auxiliary port for optional external cellular telemetry. It also offers integrated options for GOES and Iridium satellite telemetry, and supports USB and RS-232/485 for data I/O.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},638592,1793030361,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":24},5909890329169,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","TECHNICAL SPECIFICATIONS  \nF7 Data Logger  \nF7 is a rugged, high-performance data logger designed for remote environmental monitoring, with a focus on wildfire risk management applications. F7 combines durability, low power consumption, and ease of use into an integrated system with solar charging and satellite communication capabilities. Its robust design ensures reliable data collection even in harsh environments, making it an ideal choice for safety-critical applications.  \nFeaturing a sealed IP67 enclosure, military-grade connectors, and comprehensive electrical protection, F7 offers uncompromised reliability in challenging field conditions. The color touchscreen display and intuitive user interface eliminate the need for external devices for deployment and maintenance.  \nF7 includes four SDI-12 sensor ports and an auxiliary port for optional external cellular telemetry. It also offers integrated options for GOES and Iridium satellite telemetry, creating a robust platform for various weather station applications.  \n\n| \u003Cbr>MECHANICAL SPECIFICATIONS\u003Cbr>\u003Cbr>Dimensions\u003Cbr>10 x 8 x 5.7 inches\u003Cbr>(25.5 x 20.3 x 14.4 cm) |  |\n| --- | --- |\n| Case Materials | • Corrosion resistant\u003Cbr>• Powder-coated aluminum body\u003Cbr>• Glass-reinforced, injection-molded polyamide bezel |\n| Connectors | • Military-style circular connectors for sensors and power\u003Cbr>• Sealed, RFand telemetry connections\u003Cbr>• 1x USB-A host port |\n| Weight | Max w/ all options-9.25 lbs (4.2 kg)\u003Cbr>Min-8.45 lbs (3.8 kg) |\n\n\n| DATA COLLECTION AND LOGGING |  |\n| --- | --- |\n| Download Format | Downloaded as CSV |\n| Logging Capacity | >5 years, depending on configuration |\n| Internal Data Structure | Embedded database |\n| Data Collection | Full-spectrum Data Store saves all measurements to the database. |\n| Log Structure | Dynamic logging allows for post-hoc data log construction from Fullspectrum Data Store. |\n\n\n| \u003Cbr>ELECTRICAL SPECIFICATIONS\u003Cbr>\u003Cbr>Power Input\u003Cbr>• 12 V battery\u003Cbr>• 9.6 VDC to 16 VDC |  |\n| --- | --- |\n| Solar Input | 12 Vnominal, 20 W standard.>100 W, depending on site. |\n| Battery Compatibility | 12 Vnominal, VRSLA 7 Ah to >200 Ah, depending on site. |\n| Charge Regulation | • Voltage and current controlled\u003Cbr>• Temperature compensated |\n| Electrical Transient Protection | • Sensor Inputs: Gas discharge tube, series impedance, and TVS.\u003Cbr>• Power: TVS\u003Cbr>• Antenna: TVS Data I/O: Standard ESD |\n|  |  |\n| DATA I/O |  |\n| USB Device | 1x USB 2.0 Type-A supports mass storage devices |\n| Serial Port | RS-232/485 |\n\n*Preliminary specifications – details may change prior to final release .  \n[info@aem.eco](info@aem.eco)  \n[aem.eco](aem.eco)  \n| \u003Cbr>SENSOR PORTS\u003Cbr>SDI-12 • 4 discrete ports\u003Cbr>• SDI-12 v1 .3 compliant, v1 .4 compatible\u003Cbr>• Switched power\u003Cbr>• 2 Acombined switched power Analog Ports Temperature-humidity\u003Cbr>sensor and fuel stick sensor Counter Input Tipping bucket rain gauge input. |  |\n| --- | --- |\n|  |  |\n| ELECTRONIC FEATURES AND\u003Cbr>\u003Cbr>Display | USER INTERFACE\u003Cbr>• Transmissive color TFT IPS\u003Cbr>• 480x272\u003Cbr>• 0.194 mm dot pitch\u003Cbr>• LED backlight\u003Cbr>• 750 nits\u003Cbr>• 1:1500 contrast |\n| \u003Cbr>Touch Panel | Capacitive |\n| \u003Cbr>Processor | Ultra-low-power ARM 32-bit Cortex-M4 with FPU, adaptive ART, DSP |\n| \u003Cbr>Memory/Storage | • 640 KB (MCU) RAM\u003Cbr>• 2 MB (MCU) Firmware images\u003Cbr>• 8 GB eMMC Flash\u003Cbr>• 32 MB Flash |\n| \u003Cbr>OS | FreeRTOS |\n\n|  |  |\n| --- | --- |\n| GOES SATELLITE TRANSMITTER (OPTIONAL) |  |\n| Transmitter | AEM G6 |\n| Baud Rate | 300 bps or 1200 bps |\n| RF Power | • 6.3 Wmax at 300 bps\u003Cbr>• 6.34 Wmax at 1200 bps |\n| Antenna | • Directional or\u003Cbr>omnidirectional\u003Cbr>• 50 Ohm, EON2 compatible |\n|  |  |\n| IRIDIUM SBD (OPTIONAL) |  |\n| Mode | Iridium Short-burst Data |\n| Data Connection | AEM Elements® 360 |\n\n\n|  |\n| --- |\n|  |\n|  |\n\nF7 DATA LOGGER TECHNICAL SPECS  \nINTERNAL (SYSTEM) SENSORS  \nBattery  \nSolar Power  \nInternal  \n• Voltage  \n• Current  \n• Temperature  \n• Voltage  \n• Current  \nCase temperature  \nENVIRONMENTAL SPECIFICATIONS ","cbCaik44Vr4tpiAp","https://ap.wps.com/l/cbCaik44Vr4tpiAp","pdf",287785,"English","# Mechanical Specifications\n# Data Collection and Logging\n# Electrical Specifications\n# Sensor Ports and I/O\n# Electronic Features and Display\n# Satellite Transmitters (Optional)\n# Environmental Specifications\n# Voice Radio Interface (Optional)\n# External Sensors\n# Data Processes","[{\"question\":\"What are the main intended uses of the F7 Data Logger?\",\"answer\":\"The F7 Data Logger is designed for remote environmental monitoring with a focus on wildfire risk management applications, supporting reliable data collection in harsh environments.\"},{\"question\":\"How does the F7 handle power and charging in the field?\",\"answer\":\"The system supports 12 V battery input and solar input (standard 20 W, site-dependent options). Charge regulation includes voltage/current control with temperature compensation.\"},{\"question\":\"Which sensor connection options and telemetry interfaces are available?\",\"answer\":\"F7 provides four SDI-12 sensor ports plus an auxiliary port for optional external cellular telemetry. It also offers integrated options for GOES and Iridium satellite telemetry, and supports USB and RS-232/485 for data I/O.\"}]","F7 Data Logger - Datasheet - Technical Specifications | PDF",1792689573]