[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-334385-105":59,"doc-detail-334385-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","external-validation-of-the-performance-of-commercially-available-deep-learning-based-lung-nodule-detection-on-low-dose-ct-images-for-lung-cancer-screening-in-japan","External validation of the performance of commercially available deep-learning-based lung nodule detection on low-dose CT images for lung cancer screening in Japan","","External validation of commercially available deep-learning-based lung nodule detection (DL-LND) on low-dose CT (LDCT) images for lung cancer screening in Japan is investigated. The study includes 43 patients with suspected lung cancer and pathologically confirmed disease, using radiologist-defined reference standards. After DL-LND processing, detected nodules are reviewed and outcomes are assessed via sensitivity for nodules and lung cancer, positive-predictive value (PPV), and false-positive rates per scan. Findings show high sensitivity but limited PPV and elevated false positives.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/external-validation-of-the-performance-of-commercially-available-deep-learning-based-lung-nodule-detection-on-low-dose-ct-images-for-lung-cancer-screening-in-japan/334385/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/external-validation-of-the-performance-of-commercially-available-deep-learning-based-lung-nodule-detection-on-low-dose-ct-images-for-lung-cancer-screening-in-japan/334385.png","ImageObject",300,407,{"name":92,"@type":93},"Valentina","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-07","2026-09-21",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is external validation of DL-LND performance needed for lung cancer screening?","Question",{"text":112,"@type":113},"Because although AI-based lung nodule detection can assist radiologists, prior external validation on low-dose CT images is insufficient.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How were reference standards for nodules established in the study?",{"text":117,"@type":113},"For nodules exceeding 4 mm, a radiologist set the reference standard using reports from two other radiologists. Cases where the radiologist failed to identify a DL-LND-detected nodule were also included.",{"name":119,"@type":110,"acceptedAnswer":120},"What were the key performance findings for DL-LND?",{"text":121,"@type":113},"DL-LND achieved high sensitivity for lung nodules and lung cancer, but showed low PPV and a relatively high number of false-positive nodules per CT scan.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},334385,1790918518,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":4},13056703020460,"https://ap-avatar.wpscdn.com/avatar/be000253dac470eee5d?_k=1778207105932848923","Japanese Journal of Radiology (2025) 43:634–640 [https://doi.org/10.1007/s1](https://doi.org/10.1007/s1) 1604-024-01704-2  \nExternal validation of the performance of commercially available deep‑learning‑based lung nodule detection on low‑dose CT images for lung cancer screening in Japan  \nWataru Fukumoto1 · Yuki Yamashita2 · Ikuo Kawashita1 · Toru Higaki3 · Asako Sakahara1 · Yuko Nakamura1 · Yoshikazu Awaya4 · Kazuo Awai1  \nReceived: 24 July 2024 / Accepted: 5 November 2024 / Published online: 30 November 2024 © The Author(s) 2024  \nAbstract  \nPurpose Artificial intelligence (AI) algorithms for lung nodule detection have been developed to assist radiologists. However, external validation of its performance on low-dose CT (LDCT) images is insufficient. We examined the performance of the commercially available deep-learning-based lung nodule detection (DL-LND) using LDCT images at Japanese lung cancer screening (LCS) .  \nMaterials and methods Included were 43 patients with suspected lung cancer on LDCT images and pathologically confirmed lung cancer. The reference standard for nodules whose diameter exceeded 4 mm was set by a radiologist who referred to the reports of two other radiologists reading the LDCT images. After we applied commercially available DL-LND to the LDCT images, the radiologist reviewed all nodules detected by DL-LND. When he failed to identify an existing nodule, it was also included in the reference standard. To validate the performance of DL-LND, the sensitivity for lung nodules and lung cancer, the positive-predictive value (PPV) for lung nodules, and the mean number of false-positive (FP) nodules per CT scan were recorded.  \nResults The radiologist detected 97 nodules including 43 lung cancers and missed 3 solid nodules detected by DL-LND. A total of 100 nodules was included in the reference standard. DL-LND detected 396 nodules including 40 lung cancers. The sensitivity for the 100 nodules was 96.0%; the PPV was 24.2%(96/396) . The mean number ofFP nodules per CT scan was 7.0; sensitivity for lung cancer was 93.0%(40/43). DL-LND missed three lung cancers; 2 of these were atypical pulmonary cysts.  \nConclusion We externally verified that the sensitivity for lung nodules and lung cancer by DL-LND was very high. However, its low PPV and the increased FP nodules remains a serious drawback of DL-LND.  \nKeywords Artificial intelligence · Computed-aided detection · Lung cancer screening · Lung nodule · Atypical pulmonary cyst  \nAbbreviations  \n* Wataru Fukumoto [wfukumoto@hiroshima-u.ac.jp](wfukumoto@hiroshima-u.ac.jp)  \n1 Department of Diagnostic Radiology, Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3 Kasumi, Minamiku, Hiroshima 734-8551, Japan  \n2 School of Medicine, Hiroshima University, 1-2-3 Kasumi, Minamiku, Hiroshima 734-8551, Japan  \n3 Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527, Japan  \n4 Department of Respiratory Medicine, Miyoshi Central Hospital, 10531 Higashi-Sakaya-cho, Miyoshi, Hiroshima 728-8502, Japan  \nLCS  \nLDCT  \nNSLT  \nNELSON  \nAI  \nCAD  \nLIDC/IDRI  \nFP  \nDL-LNDNCCN CTDIvol  \nLung cancer screening Low-dose CT  \nNational Lung Screening  \nDutch-Belgian randomized lung cancer screening  \nArtificial intelligence  \nComputer-aided detection  \nLung Image Database Consortium and Image Database Resource Initiative False-positive  \nDeep-learning-based lung nodule detection National Comprehensive Cancer Network Computed tomography dose index  \nSD Standard deviation  \nHU Hounsfield units  \nPPV Positive-predict value  \nIntroduction  \nLung cancer remains one of the leading causes of global cancer-related mortality [1] . More than 75,000 individuals die annually of lung cancer in Japan. The 5-year survival rate is as low as 45.1% according to the annual survival report of hospital-based cancer registries from information service of national cancer center in Japan [2]; for early-stage lung cancer it","cbCaismdBdmzB6OC","https://ap.wps.com/l/cbCaismdBdmzB6OC","pdf",1008421,"English","# Abstract\n## Purpose\n## Materials and methods\n## Results\n## Conclusion\n# Keywords\n# Abbreviations\n# Introduction","[{\"question\":\"Why is external validation of DL-LND performance needed for lung cancer screening?\",\"answer\":\"Because although AI-based lung nodule detection can assist radiologists, prior external validation on low-dose CT images is insufficient.\"},{\"question\":\"How were reference standards for nodules established in the study?\",\"answer\":\"For nodules exceeding 4 mm, a radiologist set the reference standard using reports from two other radiologists. Cases where the radiologist failed to identify a DL-LND-detected nodule were also included.\"},{\"question\":\"What were the key performance findings for DL-LND?\",\"answer\":\"DL-LND achieved high sensitivity for lung nodules and lung cancer, but showed low PPV and a relatively high number of false-positive nodules per CT scan.\"}]","External validation of the performance of commercially available deep-learning-based lung nodule detection on low-dose CT images for lung cancer screening in Japan | PDF",1790006443,18]