[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-458285-105":59,"doc-detail-458285-en":123},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":116,"head_meta":118,"extra_data":120,"updated_unix":122},105,"en","exploring-spatiotemporal-information-in-a-cherenkov-and-scintillation-photon-counting-bgo-tof-pet-semi-monolithic-detector-concept","Exploring spatiotemporal information in a Cherenkov and scintillation photon counting BGO TOF-PET semi-monolithic detector concept","","Objective: Cherenkov signatures from a bismuth germanate (BGO) crystal enable time-of-flight positron emission tomography (TOF-PET) if early Cherenkov photons can be uniquely timestamped. To increase Cherenkov utility, an optical photon counting detector concept was developed using a thick semi-monolithic BGO crystal coupled to a silicon photomultiplier (SiPM) array providing digital photon timestamps per channel. Approach: A 42.68×2×20 mm³ BGO crystal was read out by a 16×1 array of 2×2 mm³ SiPMs (2.68 mm pitch) with a 16-channel fast comparator processing chain and waveform digitizers, using 3D position calibration and first-photon delay distribution (FPDD) for data-driven time-resolution improvement and Cherenkov detection probability estimation. Main results: With sufficient SiPM channels and 1.8 ns shaping, ~77% of events were uniquely timestamped by the first photon; FPDD separated photon arrival features including Cherenkov and scintillation contributions, achieving 172 ps FWHM coincidence time resolution after 3D-position correction. Significance: The study demonstrates feasibility of a photon counting BGO TOF-PET detector with strong timing and positioning potential, supporting further performance gains via data-driven Cherenkov identification and event-by-event corrections.",{"@graph":69,"@context":115},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/exploring-spatiotemporal-information-in-a-cherenkov-and-scintillation-photon-counting-bgo-tof-pet-semi-monolithic-detector-concept/458285/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/exploring-spatiotemporal-information-in-a-cherenkov-and-scintillation-photon-counting-bgo-tof-pet-semi-monolithic-detector-concept/458285.png","ImageObject",300,407,{"name":92,"@type":93},"Kyle","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",17,{"@type":107,"mainEntity":108},"FAQPage",[109],{"name":110,"@type":111,"acceptedAnswer":112},"What role does the first photon delay distribution (FPDD) play?","Question",{"text":113,"@type":114},"FPDD captures photon arrival properties and supports data-driven corrections. It separates Cherenkov and scintillation contributions and enables improved coincidence time resolution via 3D position dependence correction.","Answer","https://schema.org",{"og:url":83,"og:type":117,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":119,"canonical":83},"index,follow",{"doc_id":121,"site_id":62},458285,1791026656,{"code":4,"msg":5,"data":124},{"doc_id":121,"user_id":125,"nickname":92,"user_avatar":126,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":127,"file_id":128,"file_url":129,"file_type":130,"file_size":131,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":132,"language":133,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":134,"faqs":135,"seo_title":136,"seo_description":67,"update_tm":137,"read_time":36,"preview_page_count":19,"preview_urls":138},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Phys. Med. Biol. 71 (2026) 015032  \nPhysics in Medicine & Biology  \n[https://doi.org/10.1088/1361-6560/ae2db7](https://doi.org/10.1088/1361-6560/ae2db7)  \n| |\n| --- |\n|  |\n| OPEN ACCESS\u003Cbr>RECEIVED\u003Cbr>8 September 2025\u003Cbr>REVISED\u003Cbr>2 December 2025\u003Cbr>ACCEPTED FOR PUBLICATION 16 December 2025\u003Cbr>PUBLISHED\u003Cbr>8 January 2026 |\n\nOriginal content from this work may be used under the terms of the  \nCreative Commons Attribution 4 .0 licence.  \nAny further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.  \nPAPER  \nExploring spatiotemporal information in a Cherenkov and scintillation photon counting BGO TOF-PET semi-monolithic detector concept  \nSeungeun Lee􀁂, Ryan Heller􀁂, Woon-Seng Choong and Joshua W Cates∗􀁂  \nApplied Nuclear Physics Program, Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA, United States of America  \n∗ Author to whom any correspondence should be addressed.  \nE-mail: [JCates@lbl.gov](JCates@lbl.gov)  \nKeywords: photon counting detector, BGO TOF-PET, Cherenkov detection, analog SiPM  \n\n| Abstract\u003Cbr>Objective. Cherenkov signatures from a bismuth germanate (BGO) crystal open the possibility of establishing BGO as a promising material for time-of-flight positron emission tomography (TOF-PET) detectors, particularly if the first Cherenkov photons can be uniquely timestamped. To maximize the utility of Cherenkov signatures, we employed an optical photon counting detector concept based on a thick, semi-monolithic BGO crystal coupled to a silicon photomultiplier (SiPM) array that provides digital photon timestamps from each SiPM channel. We characterized a prototype detector to demonstrate this concept and explored the use of rich spatiotemporal information of photon transport kinetics. Approach. The detector was built using a 42.68 × 2 × 20 mm3 BGO crystal and a 16 × 1 array of 2 × 2 mm3 SiPMs with a 2 .68 mm pitch. A 16-channel low-noise high-frequency signal processing chain with fast comparators generated digital photon signals, which were recorded using waveform digitizers. Three-dimensional (3D) position calibration and first photon delay distribution (FPDD) construction provided the basis for data-driven methods to improve time resolution and estimate the probability of Cherenkov detection for each event. Main results. With a sufficient number of SiPM channels and 1.8 ns signal shaping, approximately 77% of events were uniquely timestamped with the first photon. FPDD clearly captured photon arrival properties, parameterized with the Cherenkov and scintillation contributions. A coincidence time resolution with a reference detector of 172 ps full width at half maximum was achieved by FPDD-based correction of 3D position dependence. Parameters investigated for Cherenkov detection probability estimation showed consistent correlation with time resolution. Significance. The results demonstrated the feasibility of a photon counting BGO detector for TOF-PET with both promising timing and positioning performance. The abundance of photon information provides a strong basis for further performance gains through data-driven Cherenkov identification and advanced event-by-event corrections. |\n| --- |\n| 1. Introduction\u003Cbr>Bismuth germanate (Bi4 Ge3 O 12 ; BGO) has reemerged as a promising crystal material for time-offlight positron emission tomography (TOF-PET) . Although BGO was widely used in early non-TOFPET scanners, it was eventually replaced by faster and brighter cerium-doped lutetium oxyorthosilicate (LSO:Ce) due to its long scintillation decay time (τd ∼ 300 ns) and relatively low light yield (∼8000 photons MeV −1), which are undesirable characteristics for precision timing and, consequently, do not enable TOF-PET with BGO using traditional PET instrumentation. However, key studies have highlighted the potential of exploiting prompt Cherenkov emission to enable TOF-PET with BGO (Kwon et al 2016, Brunner and Schaart 2017) ","cbCaid9sQIZm2fyl","https://ap.wps.com/l/cbCaid9sQIZm2fyl","pdf",2991442,16,"English","# Abstract\n## Objective\n## Approach\n## Main results\n## Significance\n# 1. Introduction\n## Motivation for BGO in TOF-PET\n## Cherenkov photons in BGO\n## Detector optimization goals","[{\"question\":\"What role does the first photon delay distribution (FPDD) play?\",\"answer\":\"FPDD captures photon arrival properties and supports data-driven corrections. It separates Cherenkov and scintillation contributions and enables improved coincidence time resolution via 3D position dependence correction.\"}]","Exploring spatiotemporal information in a Cherenkov and scintillation photon counting BGO TOF-PET semi-monolithic detector concept | PDF",1790752481,[139,143,147,151],{"page_no":8,"url":140,"width":141,"height":142},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6e469ad461ce08c44eadc211bddd92cf.webp",983,1390,{"page_no":14,"url":144,"width":145,"height":146},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e28c4a1ae73f82df71a3e569fdc512f5.webp",982,1388,{"page_no":81,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2ce3a2c56f5787880408d498d2fc6ee5.webp",981,1387,{"page_no":19,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/61e810abc1bf6e499627de6f741fb2c7.webp",980,1385]