[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-654534-105":59,"doc-detail-654534-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","existing-ground-floor-plan-electrical-installations","Existing Ground Floor Plan - Electrical Installations","","Existing ground floor plan notes describe stripping out kitchen units, appliances, and redundant drainage, sealing any open drains, and removing hatched walling and sanitaryware to form new openings. Electrical installations must be carried out by approved bodies under SELECT and BS 7671:2018, with certification delivered for completion. Fire alarm design specifies mains wired smoke detectors on independent circuits, spacing and mounting rules, interlinking, and full compliance with BS 5839 Part 6:2019. Lighting, sockets, ventilation equipment, and mounting heights are defined throughout.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/existing-ground-floor-plan-electrical-installations/654534/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/existing-ground-floor-plan-electrical-installations/654534.png","ImageObject",300,407,{"name":92,"@type":93},"DoDO","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-31","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to perform the electrical work, and what certification is required?","Question",{"text":112,"@type":113},"Electrical work must be undertaken by an Approved Body and Approved Certifier registered under the SELECT Registration Scheme (or an equal approved scheme). The Approved Certifier must issue a Certificate of Construction with the Scheme Checklist and appropriate BS Certification to support the Completion Certificate.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the main requirements for the fire alarm system using smoke and heat detectors?",{"text":117,"@type":113},"Mains wired smoke detectors with battery backup must be fitted on independent circuits at indicated positions, with specified spacing from walls and fittings and within distance limits to doors. Detectors must be ceiling mounted, interlinked so all units engage when one sensor triggers, and fully comply with BS 5839 Part 6 2019. A heat alarm is required within the kitchen.",{"name":119,"@type":110,"acceptedAnswer":120},"How are lighting and socket points intended to be arranged and controlled?",{"text":121,"@type":113},"Recessed down lighters must include intumescent fire hoods or be fire-rated downlighters. Switches must control power to low-level unswitched socket outlets for specified appliances, lighting points should use GU10 LED bulbs, and external lighting should use movement sensing (PIR) plus a photocell. Mounting heights and minimum distances from corners are defined for switches and sockets.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},654534,1792924393,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962093270745,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| Existing kitchen units and appliances to be stripped out. All existing high level sockets\u003Cbr>to be isolated and removed. Redundant drainage to be removed and any open drains suitably sealed.\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>Walling shown hatched to be stripped out to accommodate new opening. 1 No. robeslee type C lintel to be installed for every 100mm of walling to be supported, min end bearing 150mm.\u003Cbr>Sanitaryware shown hatched to be stripped out and any redundant drainage removed. Any open drains to be suitably sealed.\u003Cbr>Existing door shown hatched to be stripped out.\u003Cbr>\u003Cbr>\u003Cbr> 2 \u003Cbr>\u003Cbr>2\u003Cbr>2\u003Cbr>2 2 2 2 2\u003Cbr>2\u003Cbr>2 2\u003Cbr>2\u003Cbr>2 2\u003Cbr>EXISTING GROUND FLOOR PLAN\u003Cbr>ELECTRICAL INSTALLATIONS\u003Cbr>General\u003Cbr>All electrical work to be undertaken by an Approved Body and Approved Certifier registered under the SELECT Registration Scheme or any equal approved Scheme for Certification of Construction (Electrical Installations to BS 7671:2018) in accordance with the requirements of the Building (Scotland) Act 2003 Building (Procedure) (Scotland) Regulations 2015. All electrical work to be carried out in accordance with the latest edition of the IET Wiring Regulations. The Approved Certifier is to issue a Certificate of Construction along with the Scheme Checklist and appropriate British Standard (BS) Certification to the building owner to support the Completion Certificate for the work carried out on completion of the works.\u003Cbr>Fire Alarm System\u003Cbr>Mains wired (battery backed up) smoke detectors on independent circuits to be fitted in positions indicated to comply with BS EN 14604:2005 .\u003Cbr>Alarms and all detectors to be ceiling mounted, minimum 300mm away from any wall or light fitting and not directly\u003Cbr>above a heater or air conditioning outlet. All detectors tobe located on a surface which is normally at the ambient temperature of the rest of the room or space in which the smoke alarm is located and should be hardwired to a circuit which is electrically protected at the consumer unit, and to which no other equipment is connected other than a regularly used local lighting circuit.\u003Cbr>Smoke alarm must be with 7metres of a door to a living room or kitchen and within 3metres of a door to a bedroom. 1No. Smoke alarm to be fitted in each circulation space on every floor. 1 No. Smoke alarm to be located within principal habitable room (family room or lounge) . Heat alarm to be installed within kitchen.\u003Cbr>All detectors to be interlinked (via infra-red or similar) so that all units engage when one sensor is triggered.\u003Cbr>Fire alarm system to be in complete compliance with BS 5839 Part 6 2019.\u003Cbr>Lighting And Sockets\u003Cbr>All recessed down lighters to have intumescent fire hoods installed over each fitting, or alternatively fire rated downlighters to be installed. All extractor fans to have associated isolator adjacent. Switches to be wired to control power supply to low level un-switched socket\u003Cbr>outlets for washing machine, fridge freezer, tumble dryer, extractor fans and boiler. All lighting points to be fitted with low energy bulbs down lighters to be GU10 LED bulbs. External lighting to be fitted with movement sensor (e.g. PIR) and photocell to ensure operation only when required. Bulbs should be no more than 100 lamp watts. Manual switching may be provided to override operation of automatic controls. The average initial efficacy should be not less than 75 lamp lumens per circuit watt\u003Cbr>Refer to floor plans for the positions of all light switches, power sockets etc.\u003Cbr>Electrical points/switches are to be mounted at the following heights (to centre line of fitting):\u003Cbr>Light switches\u003Cbr>Power, TV sockets\u003Cbr>Power sockets at kitchen worktops worktop\u003Cbr>1050mm 500mm 150mm above\u003Cbr>All sockets to be a minimum of 350mm from an internal corner.\u003Cbr>Standard switches or unswitched socket outlets above a\u003Cbr>worktop to be at least 150mm above the projecting surface.\u003Cbr>Where sockets are concealed, such as to the rear of white goods in a kitchen, separat","cbCaihL9GfBl7fbf","https://ap.wps.com/l/cbCaihL9GfBl7fbf","pdf",716615,"English","# Electrical Installations\n## General\n## Fire Alarm System\n## Lighting And Sockets\n## Ventilation\n## Laundry Room","[{\"question\":\"Who is allowed to perform the electrical work, and what certification is required?\",\"answer\":\"Electrical work must be undertaken by an Approved Body and Approved Certifier registered under the SELECT Registration Scheme (or an equal approved scheme). The Approved Certifier must issue a Certificate of Construction with the Scheme Checklist and appropriate BS Certification to support the Completion Certificate.\"},{\"question\":\"What are the main requirements for the fire alarm system using smoke and heat detectors?\",\"answer\":\"Mains wired smoke detectors with battery backup must be fitted on independent circuits at indicated positions, with specified spacing from walls and fittings and within distance limits to doors. Detectors must be ceiling mounted, interlinked so all units engage when one sensor triggers, and fully comply with BS 5839 Part 6 2019. A heat alarm is required within the kitchen.\"},{\"question\":\"How are lighting and socket points intended to be arranged and controlled?\",\"answer\":\"Recessed down lighters must include intumescent fire hoods or be fire-rated downlighters. Switches must control power to low-level unswitched socket outlets for specified appliances, lighting points should use GU10 LED bulbs, and external lighting should use movement sensing (PIR) plus a photocell. Mounting heights and minimum distances from corners are defined for switches and sockets.\"}]","Existing Ground Floor Plan - Electrical Installations | PDF"]