[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652111-105":59,"doc-detail-652111-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","excellence-analytical-balances-xa-models-part-1-operating-instructions","Excellence Analytical Balances - XA Models - Part 1 - Operating Instructions","","Operating Instructions Part 1 for METTLER TOLEDO Excellence analytical balances, covering XA models. Provides an overview of key features and compliance with standards and quality assurance methods. Details safety information with definitions of signal warnings and product-specific safety notes. Includes step-by-step setup guidance such as unpacking, scope of delivery, selecting and leveling the balance, assembling components, power supply, draft shield operation, terminal positioning, transport procedures, and below-the-balance weighing. Also covers maintenance basics, cleaning and disposal, technical data, interface specifications, and listings of accessories and spare parts.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/excellence-analytical-balances-xa-models-part-1-operating-instructions/652111/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/excellence-analytical-balances-xa-models-part-1-operating-instructions/652111.png","ImageObject",300,407,{"name":92,"@type":93},"asda1da","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What key features are common to all XA analytical balance models?","Question",{"text":112,"@type":113},"Common features include fully automatic adjustment (FACT) using an internal weight, built-in applications for normal weighing and related functions, an integral RS232C interface, an optional second interface slot, and a touch-sensitive graphics terminal (Touch Screen).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What safety instructions must be followed before operating the balance?",{"text":117,"@type":113},"Operate and use the balance only according to Operating Instructions Part 1 and Part 2, and strictly observe the instructions for setting up the new balance to avoid hazards, damage, malfunctions, and false results.",{"name":119,"@type":110,"acceptedAnswer":120},"Which topics are included in Part 1 of the XA operating instructions?",{"text":121,"@type":113},"Part 1 covers Introduction, Safety Information, Setting up the Balance, Leveling the Balance, Cleaning and Service, Technical Data, interface commands and MT-SICS functions, Accessories, and Spare Parts.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652111,1793052071,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},3985747861852,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Operat ing Instructions  \nExcellence Analytical Balances  \nXA Models – Part 1  \n[wwwmt. com](wwwmt. com).   \nTable of contents  \n1 Introduction 5  \n 1.1 Conventions and Symbols Used in These Operating Instructions 6  \n2 Safety Information 7  \n2.1 Definition of Signal Warnings and Symbols 7  \n 2.2 Product Specific Safety Notes 7 3 Overview XA Analytical Balance 9  \n4 Setting up the Balance 10  \n4.1 Unpacking and Checking the Delivered Items 10  \n4.1.1 Unpacking the Balance 10  \n4.2 Scope of Delivery 11  \n4.3 Selecting a Location and Leveling the Balance 12  \n4.3.1 Location 12  \n4.3.2 Leveling the Balance 12  \n4.4 Assembling the Balance 13  \n4.5 Power Supply 15  \n4.6 Left/Right Operating of the Glass Draft Shield 16  \n4.7 Setting the Reading Angle and Positioning the Terminal 16  \n4.7.1 Optimise the Readability of the Terminal 16  \n4.7.2 Remove Terminal and Place Close to the Balance 16  \n4.8 Transporting the Balance 17  \n4.8.1 Transporting Over Short Distances 17  \n4.8.2 Transporting Over Long Distances 18  \n4.9 Below-the-Balance Weighing 20  \n4.10 Installing the ErgoClip 20  \n4.11 Installing the Single-use Aluminum Weighing Pan 21  \n 4.12 Installing the Grid Weighing Pan Cover 21  \n5 Maintenance 23  \n5.1 Cleaning 23  \n 5.2 Disposal 23  \n6 Technical Data 24  \n6.1 General Data 24  \n6.2 Explanatory Notes for the METTLER TOLEDO AC Adapter 24  \n6.3 Model-specific Data 25  \n6.4 Dimensions 28  \n6.5 Interfaces 29  \n6.5.1 Specifications of RS232C 29  \n 6.5.2 Specifications of \"Aux\" Connection 29  \n7 Accessories and Spare Parts 30  \n7.1 Accessories 30  \n7.2 Spare Parts 38  \nTable of contents  \n3  \n8.1 MT-SICS Interface Commands and Functions 39  8.2 Procedure for Certified Balances 39 9 Index 41  \n4  \nTable of contents  \n1 Introduction  \nThank you for choosing a METTLER TOLEDO balance.  \nThe balances of the XA line combine a large number of weighing and adjustment possibilities with exceptionally convenient operation.  \nIn this chapter you will be given basic information about your balance. Please read right through this chapter carefully even if you already have experience with METTLER TOLEDO balances. Please pay special attention to the safety warnings!  \nThe different models have different characteristics regarding equipment and performance. Special notes in the text indicate where this makes a difference to operation.  \nThe XA family of analytical balances comprises a range of analytical balances which differ from each other in relation to their weighing range and resolution.  \nThe following features are common to all models of the XA lines:  \n● Fully automatic adjustment \"FACT\" using internal weight.  \n● Built-in applications for normal weighing, statistics, percent weighing and piece counting.  \n● Integral RS232C interface.  \n● Slot for second interface (optional) .  \n● Touch-sensitive graphics terminal (\"Touch Screen\") for easy, convenient operation.  \nA brief word about standards, guidelines, and methods of quality assurance: The balances comply with usual standards and guidelines. They support standard procedures, specifications, working methods, and reports according to GLP (Good Laboratory Practice) . In this connection, records of working procedures and adjustments become very important; for this purpose we recommend you to use a printer from the METTLER TOLEDO range, since these are optimally adapted to your balance. The balances conform to the applicable standards and guidelines and possess a EC declaration of conformity. METTLER TOLEDO is certified as manufacturer according to ISO 9001 and ISO 14001.  \nThe Operating Instructions for the XA balances consist of 2 separate documents, whose contents are listed bellow.  \nPart 1, This Document  \nContents  \n● Introduction  \n● Safety Information  \n● Setting up the Balance  \n● Leveling the Balance  \n● Cleaning and Service  \n● Technical Data  \n● Interface commands and MT-SICS functions  \n● Accessories  \n● Spare Parts  \nPart 2, Separate Documen  \nContents: Terminal, System and Appli","cbCaiiGpJBJ6P11k","https://ap.wps.com/l/cbCaiiGpJBJ6P11k","pdf",1499663,44,"English","# Introduction\n## Conventions and Symbols Used in These Operating Instructions\n# Safety Information\n## Definition of Signal Warnings and Symbols\n## Product Specific Safety Notes\n# Overview XA Analytical Balance\n# Setting up the Balance\n## Unpacking and Checking the Delivered Items\n## Scope of Delivery\n## Selecting a Location and Leveling the Balance\n## Assembling the Balance\n## Power Supply\n## Left/Right Operating of the Glass Draft Shield\n## Setting the Reading Angle and Positioning the Terminal\n## Transporting the Balance\n## Below-the-Balance Weighing\n## Installing the ErgoClip\n## Installing the Single-use Aluminum Weighing Pan\n## Installing the Grid Weighing Pan Cover\n# Maintenance\n## Cleaning\n## Disposal\n# Technical Data\n## General Data\n## Explanatory Notes for the METTLER TOLEDO AC Adapter\n## Model-specific Data\n## Dimensions\n## Interfaces\n## Specifications of RS232C\n## Specifications of \"Aux\" Connection\n# Accessories and Spare Parts\n## Accessories\n## Spare Parts","[{\"question\":\"What key features are common to all XA analytical balance models?\",\"answer\":\"Common features include fully automatic adjustment (FACT) using an internal weight, built-in applications for normal weighing and related functions, an integral RS232C interface, an optional second interface slot, and a touch-sensitive graphics terminal (Touch Screen).\"},{\"question\":\"What safety instructions must be followed before operating the balance?\",\"answer\":\"Operate and use the balance only according to Operating Instructions Part 1 and Part 2, and strictly observe the instructions for setting up the new balance to avoid hazards, damage, malfunctions, and false results.\"},{\"question\":\"Which topics are included in Part 1 of the XA operating instructions?\",\"answer\":\"Part 1 covers Introduction, Safety Information, Setting up the Balance, Leveling the Balance, Cleaning and Service, Technical Data, interface commands and MT-SICS functions, Accessories, and Spare Parts.\"}]","Excellence Analytical Balances - XA Models - Part 1 - Operating Instructions | PDF",1792878154,111]