[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-640663-105":59,"doc-detail-640663-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","excel-mate-msd-technical-characteristics-product-dimensions-how-to-order","EXCEL - MATE MSD - Technical Characteristics - Product Dimensions - How to Order","","EXCEL|MATE MSD is a safe, reliable, tool-free disconnect solution for servicing HEV high-voltage systems, designed to open the HVIL circuit before separating HV contacts. It uses a two-stage lever for HVIL time delay and fingertouch-safe HV conductive contact surfaces. The dual-channel design lowers temperature rise and supports scalable configurations with integrated internal HVIL cooling. Specifications include mating cycles ≥50, fuse rating up to 630A, IP67/IP6K9K protection (mated), and operating temperature up to 125°C, with ordering options covering plug or receptacle shells and fuse/terminal configurations.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/excel-mate-msd-technical-characteristics-product-dimensions-how-to-order/640663/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/excel-mate-msd-technical-characteristics-product-dimensions-how-to-order/640663.png","ImageObject",300,407,{"name":92,"@type":93},"DoDO","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-12","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What is EXCEL|MATE MSD used for during HEV servicing?","Question",{"text":112,"@type":113},"It provides a safe, reliable, tool-free solution to disconnect the internal high voltage battery pack and protect it from short circuits during servicing.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the HVIL mechanism work?",{"text":117,"@type":113},"A two-stage lever opens the HVIL circuit prior to separation of HV contacts, providing an HVIL time delay.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the key technical specifications for operation and protection?",{"text":121,"@type":113},"It supports mating cycles of at least 50, fuse specification up to 630A, protection degree IP67 and IP6K9K (mated), and ambient/operating temperatures ranging from -40°C up to 125°C (operating).",{"name":123,"@type":110,"acceptedAnswer":124},"How can the product be ordered and configured?",{"text":125,"@type":113},"Ordering uses the EXCEL|MATE MSD plug or receptacle format with shell type selections, fuse rating current options (including 000 for no fuse), and flange mount types for front (F) or rear (R) mounting.","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},640663,1792768532,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":147,"read_time":148,"preview_page_count":4},962093270745,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","EXCEL|MATE MSD  \nAmphenol PCD Manual Service Disconnect  \nExcel| Mate MSD is a safe and a reliable solution for HEV servicing.  \nEquipped with a two-stage lever to open the HVIL circuit prior to the separation of HV contacts, it is a tool-free solution for disconnecting the internal high voltage battery pack and protecting it from short circuit. All HV conductive contact surfaces on the receptacle assembly are fingertouch safe.  \nAvailable in a scalable design with a variety of fuse ratings.  \n2  \nEXCEL|MATE MSD-TECHNICAL CHARACTERISTICS  \nKEY FEATURES  \nA two-stage lever provides an HVIL time delay  \n2 x integrated internal HVIL Unique cooling structure  \nDual-channel design lowers temperature rise  \nNo tools required to unmate Various fuse ratings  \nReceptacle can be front or rear mounted  \n\n| APPLICATION |  |\n| --- | --- |\n| It is a tool-free solution for disconnecting the internal high voltage battery pack and protecting it from short circuit. |  |\n| MECHANICAL |  |\n| Mating cycles | ≥ 50 cycles |\n| ELECTRICAL |  |\n| Fuse specification | up to 630A |\n| With fuse: |  |\n| Rated current | Current is approximately 1/3 the fuse rating |\n| Rated voltage | 500V DC to 600V DC |\n| With shunt: |  |\n| Rated current | 260A Max @ Ambient 70°C |\n| Rated voltage | 1000V DC Max |\n| ENVIRONMENTAL |  |\n| Protection degree | IP67, IP6K9K (mated) |\n| Ambient temperature | -40°C to 70°C |\n| Storage temperature | -40°C to 85°C |\n| Operating temperature | -40°C to 125°C |\n| Flammability | UL94V0 |\n\n3  \nPRODUCT DIMENSIONS  \n4  \nFRONT MOUNTED  \nREAR MOUNTED  \nDUST CAP AVAILABLE P/N: C270006810  \n5  \nHOW TO ORDER-EXCEL|MATE MSD  \nPlug  \nMSD  M 200 1  \nShell type:  \nM: Plug  \nFuse rating current:  \n200: 200A  \n250: 250A  \n315: 315A  \n350: 350A  \n400: 400A  \n450: 450A  \n500: 500A  \n550: 550A  \n630: 630A  \n000: No fuse needed, can directly use the terminal Fuse brand:  \n1: Ferraz  \n2: Bussmann  \nReceptacle  \nMSD  F 000 F  \nShell type:  \nF: Receptacle Fuse rating current:  \n000: No fuse needed, can directly use the terminal Flange mounted type:  \nF: Front mounted  \nR: Rear mounted  \n6","cbCaigidWyQubIdr","https://ap.wps.com/l/cbCaigidWyQubIdr","pdf",537494,"English","# Key Features\n## Applications\n## Mechanical\n## Electrical\n## Environmental\n# Product Dimensions\n## Front Mounted\n## Rear Mounted\n# Dust Cap Availability\n# How to Order","[{\"question\":\"What is EXCEL|MATE MSD used for during HEV servicing?\",\"answer\":\"It provides a safe, reliable, tool-free solution to disconnect the internal high voltage battery pack and protect it from short circuits during servicing.\"},{\"question\":\"How does the HVIL mechanism work?\",\"answer\":\"A two-stage lever opens the HVIL circuit prior to separation of HV contacts, providing an HVIL time delay.\"},{\"question\":\"What are the key technical specifications for operation and protection?\",\"answer\":\"It supports mating cycles of at least 50, fuse specification up to 630A, protection degree IP67 and IP6K9K (mated), and ambient/operating temperatures ranging from -40°C up to 125°C (operating).\"},{\"question\":\"How can the product be ordered and configured?\",\"answer\":\"Ordering uses the EXCEL|MATE MSD plug or receptacle format with shell type selections, fuse rating current options (including 000 for no fuse), and flange mount types for front (F) or rear (R) mounting.\"}]","EXCEL - MATE MSD - Technical Characteristics - Product Dimensions - How to Order | PDF",1792710208,13]