[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649877-105":59,"doc-detail-649877-en":135},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":128,"head_meta":130,"extra_data":132,"updated_unix":134},105,"en","excel-factory-built-chimney-installation-and-maintenance-instructions-a-major-cause-of-chimney-related-fires","EXCEL Factory Built Chimney Installation and Maintenance Instructions - A Major Cause of Chimney Related Fires","","Factory built EXCEL chimney installation and maintenance instructions emphasize maintaining required clearances (air space) to combustible materials as a primary cause of chimney-related fires. The guidance applies to solid, liquid, and gas-fired appliances, lists maximum flue gas temperature limits, and specifies using only ICC Model EXCEL components to preserve certification and warranty. It includes references to ULC S-629 (Intertek) listing, directs users to keep instructions for future use, and notes that local building/fire officials may impose installation inspection restrictions.",{"@graph":69,"@context":127},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/excel-factory-built-chimney-installation-and-maintenance-instructions-a-major-cause-of-chimney-related-fires/649877/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/excel-factory-built-chimney-installation-and-maintenance-instructions-a-major-cause-of-chimney-related-fires/649877.png","ImageObject",300,407,{"name":92,"@type":93},"Tirek","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-08","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119,123],{"name":110,"@type":111,"acceptedAnswer":112},"Why is maintaining required clearances to combustibles critical?","Question",{"text":113,"@type":114},"A major cause of chimney-related fires is failure to maintain the required clearances (air space) to combustible materials.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What types of appliances is the chimney intended for?",{"text":118,"@type":114},"The chimney is intended for use with solid, liquid, and gas-fired appliances, including wood-fired stoves, fireplaces, and furnaces.",{"name":120,"@type":111,"acceptedAnswer":121},"What temperature limits are provided for the flue gas?",{"text":122,"@type":114},"The instructions list a maximum continuous flue gas temperature of 650°C (1200°F), a brief forced firing limit of 925°C (1700°F), and testing to 1150°C (2100°F) for (3 x 30 minutes).",{"name":124,"@type":111,"acceptedAnswer":125},"Why must only ICC Model EXCEL components be used?",{"text":126,"@type":114},"Using only ICC Model EXCEL components is required; failure to do so voids the product’s certification and warranty.","https://schema.org",{"og:url":83,"og:type":129,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":131,"canonical":83},"index,follow",{"doc_id":133,"site_id":62},649877,1792833939,{"code":4,"msg":5,"data":136},{"doc_id":133,"user_id":137,"nickname":92,"user_avatar":138,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":139,"file_id":140,"file_url":141,"file_type":142,"file_size":143,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":144,"language":145,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":146,"faqs":147,"seo_title":148,"seo_description":67,"update_tm":149,"read_time":150,"preview_page_count":4},5909896572756,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","EXCEL  \nFACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS  \nA MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THIS CHIMNEY BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.  \nThis chimney is intended for use with solid, liquid and gas fired appliances, including wood fired stoves, fireplaces and furnaces.  \nMaximum continuous flue gas temperature: 650°C 1200°F  \nBrief forced firing: 925°C 1700°F  \nTested to: (3 X 30 minutes) 1150°C 2100°F  \nThe chimney should be the size recommended by the appliance manufacturer.  \nUse only ICC Model EXCEL components. Failure to do so will void the certification and warranty of the product.  \nKeep these installation and operating instructions in a safe location for future reference.  \nContact local building or fire officials about restrictions and installation inspection in your area.  \nEXCEL has been tested and listed to the ULC S-629 chimney standard by Intertek Testing Services Listing \\# 5965  \nICC INDUSTRIAL CHIMNEY COMPANY INC.  \n400 J. F. Kennedy, St. Jerome Quebec, Canada, J7Y 4B7 Tel.: (450) 565-6336  \nFax: (450) 565-6519  \n[http://www.icc-rsf.com](http://www.icc-rsf.com)  \nFOR CANADA ONLY  \nXLCND-II_2019-10  \nTable of Contents  \nEXCEL TECHNICAL SPECIFICATIONS..................................................................................... 3  \nCREOSOTE AND SOOT-Formation and need for removal.................................................. 4  \nCELLULOSE INSULATION-WARNING ............................................................................... 4  \nCOAL .................................................................................................................................... 4  \nWOOD AND COAL STOVES ................................................................................................ 4  \nOPERATION AND MAINTENANCE ...................................................................................... 5  \nCHIMNEY FIRES .................................................................................................................. 5  \nINSTALLATION NOTES........................................................................................................ 6  \nFACTORY BUILT FIREPLACE ............................................................................................. 7  \nOIL AND GAZ APPLIANCES ................................................................................................ 7  \nCHIMNEY HEIGHT ............................................................................................................... 7  \nINSTALLATION INSTRUCTIONS ............................................................................................... 8  \nROUND SUPPORT (ERDS) & SQUARE SUPPORT (ESS) .................................................. 8  \nINSULATED ROUND SUPPORT (ERDSI) ............................................................................ 8  \nTYPICAL INSTALLATIONS................................................................................................... 8  \nCATHEDRAL CEILINGS ..................................................................................................... 12  \nSUPPORT EXTENSIONS-ROUND (ERDSE) OR SQUARE (ESSE) ................................. 13  \nUNIVERSAL BAND AND ROOF SUPPORT BAND ASSEMBLY ......................................... 14  \nROOF SUPPORT (ESR) ..................................................................................................... 15  \nOFFSET SUPPORT (EOS) ................................................................................................. 16  \nOFFSET CHIMNEY............................................................................................................. 17  \nWALL SUPPORT (EWS) ..................................................................................................... 20  \nWALL RADIATION SHIELD (EWRS) ...........................","cbCaiaYVzE7lSwjk","https://ap.wps.com/l/cbCaiaYVzE7lSwjk","pdf",1652699,31,"English","# EXCEL Technical Specifications\n## Creosote and Soot-Formation and need for removal\n## Cellulose Insulation-WARNING\n## Operation and Maintenance\n## Chimney Fires\n# Installation Instructions\n## Factory Built Fireplace\n## Oil and GAZ Appliances\n## Chimney Height\n## Round Support (ERDS) & Square Support (ESS)\n## Insulated Round Support (ERDSI)\n## Typical Installations\n## Cathedral Ceilings\n## Support Extensions-Round (ERDSE) or Square (ESSE)\n## Universal Band and Roof Support Band Assembly\n## Roof Support (ESR)\n## Offset Support (EOS)\n## Offset Chimney\n## Wall Support (EWS)\n## Wall Radiation Shield (EWRS)\n## Through Wall Installation\n## Wall Channel\n## Roof Brace (ERB)\n## Adjustable Length (ELA18)\n## Anchor Plate (EAP)\n## Radiation Shield (ERS & ERSA)\n## Rain Cap Base (ERCB)\n## Storm Collar (ESC, ESQSC)\n## Snow-Barrier (ESW)\n## Extended Wall Support (EWSE)","[{\"question\":\"Why is maintaining required clearances to combustibles critical?\",\"answer\":\"A major cause of chimney-related fires is failure to maintain the required clearances (air space) to combustible materials.\"},{\"question\":\"What types of appliances is the chimney intended for?\",\"answer\":\"The chimney is intended for use with solid, liquid, and gas-fired appliances, including wood-fired stoves, fireplaces, and furnaces.\"},{\"question\":\"What temperature limits are provided for the flue gas?\",\"answer\":\"The instructions list a maximum continuous flue gas temperature of 650°C (1200°F), a brief forced firing limit of 925°C (1700°F), and testing to 1150°C (2100°F) for (3 x 30 minutes).\"},{\"question\":\"Why must only ICC Model EXCEL components be used?\",\"answer\":\"Using only ICC Model EXCEL components is required; failure to do so voids the product’s certification and warranty.\"}]","EXCEL Factory Built Chimney Installation and Maintenance Instructions - A Major Cause of Chimney Related Fires | PDF",1792810098,78]