[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-663008-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-663008-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","example-foundation-plan-residential-52-0","Example Foundation Plan - Residential - 52'-0”","","Example foundation plan content for a residential project, provided solely to demonstrate the level of detail required on construction drawings. Includes notes on Canadian code compliance, specifying that drawings must be prepared by a professional and that these examples must not be used as actual construction plans. Provides foundation elements and dimensions such as openings, floor drains, sump pump diameter, radon rough-in piping, footing and wall sizes, perimeter drainage, and typical framing components, plus office contact information and update timestamp.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/example-foundation-plan-residential-52-0/663008/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/example-foundation-plan-residential-52-0/663008.png","ImageObject",300,407,{"name":42,"@type":43},"Kyle","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":26},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"Are these drawings permitted to be used as actual construction plans?","Question",{"text":62,"@type":63},"No. The document states they are examples only and should not be used as construction plans.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What code-related guidance is included with the drawings?",{"text":67,"@type":63},"The text instructs users not to refer to the drawings for National Building Code of Canada requirements and notes that other information may be requested to demonstrate compliance when reviewing an application.",{"name":69,"@type":60,"acceptedAnswer":70},"What professional requirement is stated for preparing drawings?",{"text":71,"@type":63},"Drawings must be prepared by a professional capable of designing in accordance with the National Building Code of Canada.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},663008,1793224444,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":26,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":30},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","EXAMPLE FOUNDATION PLAN  \nRESIDENTIAL  \nSOUTHEAST REGIONAL SERVICE COMMISSION • COMMISSION DE SERVICES RÉGIONAUX DU SUD-EST  \nPlease be advised that these are examples only and should not be used as construction plans. Do not refer to these drawings for National Building Code of Canada requirements; these are examples to demonstrate the level of detail necessary on construction drawings. Other information may be requested upon reviewing your application, when necessary, to show National Building Code of Canada compliance.  \nDrawings must be prepared by a professional capable of designing in accordance with the National Building Code of Canada.  \n52’-0”  \nWINDOW 48”X 24”LINTEL 2 PLY 2”X10”  \nOPENING IN CONCRETE 3’-4” X 2’-6”  \nFLOOR DRAIN  \nSUMP PUMP DIA. 18”  \nW. H.  \nHRV  \nBEAM POCKET  \n7” WIDE X 7 3/4” HIGH 4” DEEP  \n(1/2” CLEARANCE ALL SIDES)  \nPROVIDE DRAIN FOR CONDENSATE PIPE  \nABOVE FLOOR OUTLET CAPPED SEE DETAIL  \nFLOOR JOIST 11 7/8”@ 16”C/C FLOOR JOIST 11 7/8”@ 16”C/C FLOOR JOIST 11 7/8”@ 16”C/C  \nADJUSTABLE METAL POST DIA. 3”  \nRADON ROUGH-IN 4” PIPE INSTALLED UNDER THE FLOOR  \nOPENING IN CONCRETE 10’-2” X 2’-6”  \nCOLUMN FOOTING 28”X28”X10”  \nFOUNDATION WALL 0’-8”  \nFOOTING 1’-8”X8”  \nPERIMETER DRAINAGE  \n4” PERFORATED PIPE  \nCONCRETE FLOOR 4”  \nBACKFILL HEIGHT REDUCED DUE TO WINDOW SIZE  \n72”X 24” (OVER 4’-0”WIDE)  \nFOOTING 18”X 8”CENTERED UNDER WALL  \nUNDER FLOOR INTAKE AT CENTER OF FLOOR  \nLINTEL 2 PLY 2”X10”  \nSMOKE ALARM  \nLOAD BEARING WALL 2”X6”@ 16” C/C  \nDOUBLE TOP PLATESON ALL LOAD BEARING WALLS  \nBEAMS 4-2”X10”  \nDECK JOIST 2”X8”  \nBEAM 2 PLY 2”X10”  \n5’-11”  \n23’-7”  \n52’-0”  \n40’-8”  \n20’-5” 20’-3”  \n6”X6” POST  \n10’-11”  \n8” DIA. CONC. PIERS WITH 24” FOOTINGS  \n~~ ~~ ATTACH BEAM WITH BEAM POCKET  \nMain Office  \n1234, rue Main Street, 2nd floor, Unit/Unité 200 Moncton, NB, E1C 1H7  \nTel: 506-382-5386  \nBeaubassin Office  \n815A, rue Bombardier Street Shediac, NB, E4P 1H9  \nTel: 506-533-3637  \nTantramar Office  \n112C, rue Main Street Sackville, NB, E4L 0C3  \nTel: 506-364-4701  \nLast Updated April 29, 2026","cbCaieGfjcoV6qnD","https://ap.wps.com/l/cbCaieGfjcoV6qnD","pdf",270014,"English","# Residential\n## Foundation layout and dimensions\n## Mechanical and drainage provisions\n## Framing and structural notes\n## Contact information and update date","[{\"question\":\"Are these drawings permitted to be used as actual construction plans?\",\"answer\":\"No. The document states they are examples only and should not be used as construction plans.\"},{\"question\":\"What code-related guidance is included with the drawings?\",\"answer\":\"The text instructs users not to refer to the drawings for National Building Code of Canada requirements and notes that other information may be requested to demonstrate compliance when reviewing an application.\"},{\"question\":\"What professional requirement is stated for preparing drawings?\",\"answer\":\"Drawings must be prepared by a professional capable of designing in accordance with the National Building Code of Canada.\"}]","Example Foundation Plan - Residential - 52'-0” | PDF"]