[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649833-105":59,"doc-detail-649833-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","example-foundation-plan-construction-drawings","EXAMPLE FOUNDATION PLAN - Construction drawings","","Example foundation plan for a residential southeast regional service commission submission, presenting construction drawing elements and required detail levels. The content specifies compliance context with the National Building Code of Canada and instructs that drawings must be prepared by a qualified professional. Included details cover foundation walls, footing dimensions, perimeter drainage with perforated pipe, radon rough-in piping, sump pump and HRV-related provisions, floor framing members, lintels, floor drains, and site address/office contact information.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/example-foundation-plan-construction-drawings/649833/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/example-foundation-plan-construction-drawings/649833.png","ImageObject",300,407,{"name":92,"@type":93},"Danger Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the document’s purpose and how should the drawings be used?","Question",{"text":112,"@type":113},"It provides example foundation drawings only. They must not be used as construction plans and should not be referenced for National Building Code of Canada requirements.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Who is responsible for preparing the final construction drawings?",{"text":117,"@type":113},"Drawings must be prepared by a professional capable of designing in accordance with the National Building Code of Canada.",{"name":119,"@type":110,"acceptedAnswer":120},"What major foundation systems and details are shown?",{"text":121,"@type":113},"The plan includes foundation wall and footing dimensions, perimeter drainage with a perforated pipe, radon rough-in piping under the floor, sump pump provisions, and structural framing elements like joists, beams, and lintels, plus a smoke alarm location.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649833,1792808992,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962090769052,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","EXAMPLE FOUNDATION PLAN  \nRESIDENTIAL  \nSOUTHEAST REGIONAL SERVICE COMMISSION • COMMISSION DE SERVICES RÉGIONAUX DU SUD-EST  \nPlease be advised that these are examples only and should not be used as construction plans. Do not refer to these drawings for National Building Code of Canada requirements; these are examples to demonstrate the level of detail necessary on construction drawings. Other information may be requested upon reviewing your application, when necessary, to show National Building Code of Canada compliance.  \nDrawings must be prepared by a professional capable of designing in accordance with the National Building Code of Canada.  \n52’-0”  \nWINDOW 48”X 24”LINTEL 2 PLY 2”X10”  \nOPENING IN CONCRETE 3’-4” X 2’-6”  \nFLOOR DRAIN  \nSUMP PUMP DIA. 18”  \nW. H.  \nHRV  \nBEAM POCKET  \n7” WIDE X 7 3/4” HIGH 4” DEEP  \n(1/2” CLEARANCE ALL SIDES)  \nPROVIDE DRAIN FOR CONDENSATE PIPE  \nABOVE FLOOR OUTLET CAPPED SEE DETAIL  \nFLOOR JOIST 11 7/8”@ 16”C/C FLOOR JOIST 11 7/8”@ 16”C/C FLOOR JOIST 11 7/8”@ 16”C/C  \nADJUSTABLE METAL POST DIA. 3”  \nRADON ROUGH-IN 4” PIPE INSTALLED UNDER THE FLOOR  \nOPENING IN CONCRETE 10’-2” X 2’-6”  \nCOLUMN FOOTING 28”X28”X10”  \nFOUNDATION WALL 0’-8”  \nFOOTING 1’-8”X8”  \nPERIMETER DRAINAGE  \n4” PERFORATED PIPE  \nCONCRETE FLOOR 4”  \nBACKFILL HEIGHT REDUCED DUE TO WINDOW SIZE  \n72”X 24” (OVER 4’-0”WIDE)  \nFOOTING 18”X 8”CENTERED UNDER WALL  \nUNDER FLOOR INTAKE AT CENTER OF FLOOR  \nLINTEL 2 PLY 2”X10”  \nSMOKE ALARM  \nLOAD BEARING WALL 2”X6”@ 16” C/C  \nDOUBLE TOP PLATESON ALL LOAD BEARING WALLS  \nBEAMS 4-2”X10”  \nDECK JOIST 2”X8”  \nBEAM 2 PLY 2”X10”  \n5’-11”  \n23’-7”  \n52’-0”  \n40’-8”  \n20’-5” 20’-3”  \n6”X6” POST  \n10’-11”  \n8” DIA. CONC. PIERS WITH 24” FOOTINGS  \n~~ ~~ ATTACH BEAM WITH GALVANIZED BEAM HANGER  \nMain Office  \n1234, rue Main Street, 2nd floor, Unit/Unité 200 Moncton, NB, E1C 1H7  \nTel: 506-382-5386  \nBeaubassin Office  \n815A, rue Bombardier Street Shediac, NB, E4P 1H9  \nTel: 506-533-3637  \nTantramar Office  \n112C, rue Main Street Sackville, NB, E4L 0C3  \nTel: 506-364-4701  \nRiverview Office  \nOperations Centre  \n300, rue Robertson Street Riverview, NB, E1B 0T8  \nTel: 506-382-3574","cbCaie0NagnV7Bed","https://ap.wps.com/l/cbCaie0NagnV7Bed","pdf",260280,"English","# Residential foundation layout\n## Key drawing notes and code compliance\n## Foundation and drainage components\n## Structural framing and openings\n## Mechanical provisions and alarms\n## Office contacts","[{\"question\":\"What is the document’s purpose and how should the drawings be used?\",\"answer\":\"It provides example foundation drawings only. They must not be used as construction plans and should not be referenced for National Building Code of Canada requirements.\"},{\"question\":\"Who is responsible for preparing the final construction drawings?\",\"answer\":\"Drawings must be prepared by a professional capable of designing in accordance with the National Building Code of Canada.\"},{\"question\":\"What major foundation systems and details are shown?\",\"answer\":\"The plan includes foundation wall and footing dimensions, perimeter drainage with a perforated pipe, radon rough-in piping under the floor, sump pump provisions, and structural framing elements like joists, beams, and lintels, plus a smoke alarm location.\"}]","EXAMPLE FOUNDATION PLAN - Construction drawings | PDF"]