[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-403440-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-403440-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","example-building-owneroccupant-preparation-checklist-specialtygas-fumigant","EXAMPLE BUILDING OWNER/OCCUPANT PREPARATION CHECKLIST - Specialtygas Fumigant","","EXAMPLE BUILDING OWNER/OCCUPANT PREPARATION CHECKLIST outlines preparation steps for building owners and occupants before structural fumigation using Vikane® gas fumigant (and notes related guidance for specialty gas fumigant). It specifies what can remain in place under airtight manufacturer seals, exceptions for items such as certain dental hygiene products and cosmetics, and actions for doors, attic openings, appliances, mattresses, heating elements, and pilot lights. It also covers gas shutoff arrangements, relocation and removal of people, pets, plants, and fish-tank preparation, plus locking and notification requirements, aeration and reentry clearance responsibilities, and additional fumigation-company-dependent requirements for tarpaulin fumigation.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/example-building-owneroccupant-preparation-checklist-specialtygas-fumigant/403440/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/example-building-owneroccupant-preparation-checklist-specialtygas-fumigant/403440.png","ImageObject",300,407,{"name":42,"@type":43},"Emma Wilson","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-07","2026-09-27",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",17,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What food, feed, drugs, and medicinals can stay in the building during Vikane fumigation?","Question",{"text":63,"@type":64},"Items can remain if they are in plastic, glass, or metal bottles, cans, or jars with the original airtight seal intact. Otherwise, they must be removed or double-bagged in Nylofume® bags.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What must be done with open interior spaces and appliances before fumigation begins?",{"text":68,"@type":64},"Open operable internal doors, openings to attics and sub areas, storage chests, cabinets, drawers, closets, and appliances such as washers, dishwashers, dryers, and microwave or conventional ovens.",{"name":70,"@type":61,"acceptedAnswer":71},"When is it allowed to reenter the fumigated structure?",{"text":72,"@type":64},"The fumigated structure must not be reentered until it has been declared cleared for reentry by the licensed fumigator.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},403440,1791045549,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,110,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":108,"slug":109},7,40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":112,"show_sort_weight":113,"slug":114},8,"Research & Report",30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":107,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":97,"preview_page_count":4},3848291630094,"https://eur-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","Vikane  \nEXAMPLE BUILDING OWNER/OCCUPANT PREPARATION CHECKLIST  \n# SPECIALTYGAS FUMIGANT\n\nThis document provides examples of items to put in a customer checklist to help building occupants and ownersprepare for a structural fumigation with Vikane®gas fumigant.  \nThe items listed below are required to be conducted by the labeling for Vikane.If the customer does not prepareitems as required by the labeling,it is the responsibility of the certified applicator in charge to ensure these actionsare completed prior to fumigating the building with Vikane.  \n□ Food,feed,drugs(including tobacco products),and medicinals (including those items in refrigerators andfreezers)can remain in the building if they are in plastic,glass,or metal bottles,cans,or jars with the originalmanufacturer's air-tight seal intact.Otherwise,these items need to be removed from the building or doublebagged in Nylofume®bags,which are available from the fumigator.  \n□ EXCEPTION:Opened items that do not need to be removed or sealed in Nylofume bags include dental hygieneproducts(including toothpaste,mouthwash,dental adhesives,and dental whitening products),cosmeticsincluding lipstick,all externally applied lotions and ointments,ice and water.  \n□ Open operable internal doors,internal openings to attics and sub areas,storage chests,cabinets,drawers,closets,and appliances(such as washers,dishwashers,dryers,microwave or conventional ovens,etc.).  \n□ For mattresses (excluding waterbeds)and pillows completely enveloped in waterproof coverings,do one of thefollowing:1)open the seal of the water proof covering or 2)remove the mattress or pillow from the space tobe fumigated if the waterproof covering cannot be opened.Mattresses and pillows with waterproof coveringscontaining built-in vents designed to permit air passage are considered to have an open seal to the waterproofcovering and can remain as-is in the fumigated space.  \n□ All heating elements must be unplugged(heaters,pianos,organs,etc.).  \n□ All pilot lights must be extinguished (hot water heaters,ranges,ovens,broilers,gas refrigerators,dryers,automatic lighting systems,etc.).  \n□ Make arrangements to turn off all gas at main valve or tank.  \n□ Water the ground around shrubs and plants located adjacent to the building foundation.  \n□ All people must leave and all domestic animals,pets,and desirable growing plants must be removed from yourbuilding before the fumigation begins.  \n□ Remove fish tanks containing live fish,or remove the fish,or develop a plan for preparing the tank forfumigation.If necessary,exclude water in the tank and biological filters,if present,from the fumigated spaceby sealing with gas resistant tarps or sheeting.If water aeration is required during fumigation,provide fresh airfrom outside the fumigated space for the tank aerator.  \n□ The law requires that allbuildings be locked during a fumigation.In addition,all buildings shall have asecondary lock/barricade on all exterior doors during the fumigation.  \n□ Notify the company prior to the fumigation if any conduits,tunnels,pathways,etc.,are connecting the buildingto be fumigated to any other structure.  \n□ The fumigated structure must not be reentered until it has been declared cleared for reentry by the licensed fumigator.  \nThe items below are not required by the labeling for Vikane⑨gas fumigant,but are often required by fumigationcompanies based on their experience in conducting structural fumigation.Check with your state requirementsfor structural fumigation to see if additional notifications are required of building owners and occupants prior tofumigation.  \n□ Shut off automatic switch controls for appliances and lighting systems that will be included in the space to befumigated.  \n□ Electricity must be available,as it willbe required to run fans during the fumigation period.  \n□ For tarpaulin fumigation,cut back shrubbery and tree branches to prevent damage.Provide enough space(at least 12-18 inches)between the building and plantings for","cbCaigCYwVTqrwzx","https://ap.wps.com/l/cbCaigCYwVTqrwzx","pdf",2352216,"English","# SPECIALTYGAS FUMIGANT\n## Required preparations by the labeling for Vikane gas fumigant\n## Additional items often required by fumigation companies","[{\"question\":\"What food, feed, drugs, and medicinals can stay in the building during Vikane fumigation?\",\"answer\":\"Items can remain if they are in plastic, glass, or metal bottles, cans, or jars with the original airtight seal intact. Otherwise, they must be removed or double-bagged in Nylofume® bags.\"},{\"question\":\"What must be done with open interior spaces and appliances before fumigation begins?\",\"answer\":\"Open operable internal doors, openings to attics and sub areas, storage chests, cabinets, drawers, closets, and appliances such as washers, dishwashers, dryers, and microwave or conventional ovens.\"},{\"question\":\"When is it allowed to reenter the fumigated structure?\",\"answer\":\"The fumigated structure must not be reentered until it has been declared cleared for reentry by the licensed fumigator.\"}]","EXAMPLE BUILDING OWNER/OCCUPANT PREPARATION CHECKLIST - Specialtygas Fumigant | PDF",1790540418]