[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-459293-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-459293-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","ex-vivo-validation-of-nine-algorithms-for-quantifying-infarcts-with-late-gadolinium-enhancement-cardiovascular-magnetic-resonance","Ex-vivo validation of nine algorithms for quantifying infarcts with late gadolinium enhancement cardiovascular magnetic resonance","","Late gadolinium enhancement (LGE) cardiovascular magnetic resonance is the reference approach to visualize myocardial infarction (MI), yet published infarct-quantification algorithms are rarely validated against an ex-vivo benchmark and show inconsistent performance. This study compared nine infarct measurement algorithms against ex-vivo high-resolution T1-weighted measurements in a porcine model. MI was induced in 22 pigs, with in-vivo LGE imaging at d0/d3/d7, and infarct size assessed by multiple automated methods plus manual delineation. Variance and bias differed across algorithms, with EWA, FWHM, and FACT showing the best agreement, while experienced-reader manual delineation remained reliable.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/ex-vivo-validation-of-nine-algorithms-for-quantifying-infarcts-with-late-gadolinium-enhancement-cardiovascular-magnetic-resonance/459293/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/ex-vivo-validation-of-nine-algorithms-for-quantifying-infarcts-with-late-gadolinium-enhancement-cardiovascular-magnetic-resonance/459293.png","ImageObject",300,407,{"name":42,"@type":43},"Ivy","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-01","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What was the purpose of this study?","Question",{"text":63,"@type":64},"To compare the performance of infarct measurement algorithms against an ex-vivo measurement and discuss advantages and disadvantages of different methods.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How was infarct size validated in this work?",{"text":68,"@type":64},"Infarct size was validated ex vivo using high-resolution T1-weighted images, serving as the benchmark for algorithm performance.",{"name":70,"@type":61,"acceptedAnswer":71},"Which methods performed best relative to manual delineation?",{"text":72,"@type":64},"EWA, Heiberg-08, FWHM, and FACT performed on par with manual delineation overall; however, Heiberg-08 and FWHM were not suitable for phase sensitive inversion recovery images.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},459293,1790790898,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":113,"preview_page_count":33,"preview_urls":145},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","Journal of Cardiovascular Magnetic Resonance 27 (2025) 101915  \nContents lists available at ScienceDirect  \nJournal of Cardiovascular Magnetic Resonance  \njournal [homepage:](homepage: www.sciencedirect.com/journal/joc mr)[ www.sciencedirect.com/journal/joc mr](homepage: www.sciencedirect.com/journal/joc mr)  \nOriginal research  \nEx-vivo validation of nine algorithms for quantifying infarcts with late gadolinium enhancement cardiovascular magnetic resonance  \nSascha Kopica, Einar Heiberga,b, Henrik Engbloma, Marcus Carlssona, David Nordlunda, Robert Jablonowskia, Mikael Kanskia, Christos Xanthisa, Sebastian Bidhulta,  \nAnthony H. Aletrasa,c, Håkan Arhedena,⁎  \naLund University, Department of Clinical Sciences Lund, Clinical Physiology, Skane University Hospital, Lund, Sweden bLund University, Wallenberg Center for Molecular Medicine, Lund, Sweden  \nc School of Medicine, Aristotle University of Thessaloniki, Laboratory of Computing, Medical Informatics and Biomedical – Imaging Technologies, Thessaloniki, Greece  \nA R T I C L E I N F O  \nKeywords:  \nLate gadolinium enhancement Infarct size  \nQuantification Accuracy Precision  \nA B S T R A C T  \nBackground: In cardiovascular magnetic resonance, late gadolinium enhancement (LGE) is the standard method to visualize myocardial infarction (MI). Many algorithms quantifying infarct size in LGE images exist. However, only few algorithms have been validated, i.e., benchmarked against an ex-vivo measurement. Furthermore, the reported algorithm performance varies considerably between studies.  \nObjectives: The aim of this study was to compare the performance of all infarct measurement algorithms against an ex-vivo measurement and to promote a discourse regarding advantages and disadvantages of individual measurement methods.  \nMethods: MI was induced in 22 pigs. In-vivo LGE imaging was conducted on d0, d3 or d7 post-MI. For ex-vivo validation infarct was measured using high-resolution T1-weighted images. In-vivo infarct size was measured using the full-width at half-maximum (FWHM), n-SD from remote (2,3,5, and 6 SD), feature analysis and combined thresholding (FACT), expectation maximization-weighted A priori information (EWA), Heiberg-08 and Otsu algorithms and manual delineation. No manual adjustments were made to algorithm delineations. Results: Clear differences in variance and bias were observed between algorithm-based methods, and no method performed optimally in this heterogeneous dataset where the best had a bias of −0.48 ± 3.1, −0.3 ± 4.4%, 2.3 ± 4.2% left ventricle for EWA, FWHM, and FACT, respectively. Manual delineation by experienced observers performed well with a bias of 1.9 ± 5.4%.  \nConclusion: EWA, Heiberg-08, FWHM, and FACT all perform on par with manual delineation, however, Heiberg- 08, and FWHM are not suitable for phase sensitive inversion recovery images. The technique used to measure infarct size should be disclosed in clinical trials and in original research. Caution should be applied when comparing datasets employing different infarct quantification methods. Manual infarct delineation by experienced readers remains a reliable technique to measure infarct size.  \n1. Introduction  \nCardiovascular magnetic resonance (CMR) has become an increasingly important method for the characterization of myocardial infarction (MI). The reference standard for infarct size measurement with CMR is late gadolinium enhancement (LGE) imaging [1]. LGE  \nsequences visualize T1-weighted image contrast by leveraging the volume distribution of the extracellular contrast agent between areas with high extracellular volume fractions, such as necrotic or scarred myocardium, and viable myocardium [2]. The ability to accurately quantify MI has led to a rise of the utilization of CMR in clinical routine, but also in clinical trials [3,4].  \nAbbreviations: CMR, Cardiovascular Magnetic Resonance; EWA, Expectation maximization-Weighted intensity-A priori information; FACT, Feature Analysis and Comb","cbCailqX80A3FUGF","https://ap.wps.com/l/cbCailqX80A3FUGF","pdf",6873725,12,"English","# Introduction\n# Methods\n## In-vivo LGE imaging and ex-vivo validation\n## Infarct quantification algorithms\n# Results\n# Conclusion","[{\"question\":\"What was the purpose of this study?\",\"answer\":\"To compare the performance of infarct measurement algorithms against an ex-vivo measurement and discuss advantages and disadvantages of different methods.\"},{\"question\":\"How was infarct size validated in this work?\",\"answer\":\"Infarct size was validated ex vivo using high-resolution T1-weighted images, serving as the benchmark for algorithm performance.\"},{\"question\":\"Which methods performed best relative to manual delineation?\",\"answer\":\"EWA, Heiberg-08, FWHM, and FACT performed on par with manual delineation overall; however, Heiberg-08 and FWHM were not suitable for phase sensitive inversion recovery images.\"}]","Ex-vivo validation of nine algorithms for quantifying infarcts with late gadolinium enhancement cardiovascular magnetic resonance | PDF",1790755612,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4259e62698c662501bc766023d9ce439.webp",983,1310,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/88190b51b97634b3a6c9ef56542c4236.webp",982,1309,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b62b0c21f562b215a03124696945ccc2.webp",981,1308,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/60658b68055ce9d00868a254dba98779.webp",980,1306]